A Study on the Wearing Comfort of Firefighter's Protective Clothing

한국 소방방수피복의 착용만족도 및 개선방안에 관한 조사연구

  • Published : 1999.12.01

Abstract

This study analyzed firefighter's actual wearing condition of turnout gear The results are as fellows: 1. When a firefighter is employed, Korea applies only the minimum of firefighters stature and weight but America applies both the minimum and the maximum. The choice of size is highly related with stature more than chest circumference. 2. The satisfaction degree of thermal barrier is very low, 3%. They used rubber gloves rather than heatproof gloves. This is more serious in small country like 'up', 'myun' than in cities. For laundering, they used sprinkling method with firefighting hose. Firefigthers hoped that their clothes could be classified tv the seasons and fire places. 3. frefighter had high unsatisfaction with the movement of hands and leges in the aspect of movement adjustability, air permeability, weight, body temperature regulation, and breathing in the hygenic aspect, fire resistance, thermal resistance property, water proof, chemical reactivity and electrical conductivity. Thev were also unsatisfied with water proof boots and gloves. They were generally satisfied with helmets but firefighters over 90kg of weight were rather unsatisfied. 4. The satisfaction degree for physical fitness was very low and the items with which they were not satisfied depend on physical features. 5. To develop turnout gear, they wanted changes in design, material and size. Reflection tape need to be replaced with high quality products and they wanted the use of velcro and zipper in fastening system.

Keywords