• Title/Summary/Keyword: Fire Fighters

Search Result 142, Processing Time 0.034 seconds

Flow Analysis of Building Pressurization System for Smoke Control (건물의 가압방연시스템 설계를 위한 유동해석에 관한 연구)

  • 김명배;한용식
    • Fire Science and Engineering
    • /
    • v.14 no.2
    • /
    • pp.14-20
    • /
    • 2000
  • Many pressurization systems are designed and built with the goal of providing a smoke-free escape route in the event of a building fire. A secondary objective is to provide a smoke-free staging area for fire fighters. In the present study, a computer program is developed to calculate pressure loss and flow rate at several building elements such as a room, a ]tabby a staircase and an air supply shaft. By the program as the dosing tool for the pressurization system, the capacity of the injection fan is calculated, and the design method is proposed for the optimization of the fan capacity.

  • PDF

Analysis of Work Postures of Fire Fighters for Prevention of Musculoskeletal Disorders (소방대원들의 근골격계질환 예방을 위한 작업 자세 분석)

  • Roh, Hyo-Lyun;Son, Sung-Min;Oh, Hyun-Soo;Chang, Seong-Rok;Kim, Yong-Jae
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.71-78
    • /
    • 2011
  • The aim of study was to reduce risk factors of musculoskeletal disorders, and prevent it according to evaluation and analysis of its symptoms survey, and work postures which doing much frequently. This study was conducted by 64 firefighters. It was surveyed physical burden levels, distribution of musculoskeletal symptoms, and analized work postures by using ergonomics tools, such as Rapid Entire Body Assesment(REBA), Rapid Upper Lim Assessment(RULA), NIOSH Lifting Equation(NLE). Physical burden levels, and distribution of musculoskeletal symptoms were surveyed according to frequency analysis, and the analysis of above tools were presented figures and scores. The all the results of REBA were that risk level was "High", action level was "Need soon" and the results of RULA were "The results are required detailed survey and immediate improvement" at Require rescue person handling, fire hose, hybraulic rescue equipment, universal axe work postures. The occurrence possibility of musculoskeletal disorders of fire fighters is quite high due to instability postures, excessive physical work and so on. Thus, making various efforts to prevent disorders, and improving working environment is necessary continuously.

A study on the Improvements of the Fire Officials' Employment (소방공무원 공개채용 시험과목 조정에 관한 연구)

  • Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.153-161
    • /
    • 2008
  • The duty of fire officials are very complicated and various that a subject replacement for the fire officials' public examination for service is being required. The purpose of this study is to investigate the actual conditions of the fire officials' public employment system and find out current problems of it, to reconsider the speciality of the examination based on them, and to suggest a subject replacement for the examination to evaluate the duty accomplishment ability. This study presents not only assuring the speciality of fire officials but also the desirable plans to execute the Fire Relating Act effectively by replacing introduction of political science with fire service administration and adding the Fire Relation Law which is more connected on the local fire officials public written examination for service with duty.

Impact of Disaster Perception and Satisfaction on the Continuity of Volunteering in Volunteer Fire-fighters (의용소방대원들의 재난에 대한 인식과 만족이 자원봉사활동 지속성에 미치는 영향)

  • Lim, Seyoung;Lee, Hyeonji;Choi, Miyoung;Hwang, Jeonghyeon;Kim, Munui;Moon, Taeyoung
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.191-202
    • /
    • 2015
  • The purpose of this study was to examine the influence of the disaster perception and satisfaction level of volunteer fire-fighters on the continuity of their volunteering. The 163 subjects in this study were selected from male and female volunteer fire-fighters who resided in urban and rural regions in Gangwon Province. After a this survey was conducted, the collected data were analyzed by a statistical package SPSS WIN 20.0, and frequency analysis, correlation analysis and multiple regression analysis were made. The level of statistical significance was all set at p<.05. The findings of the study were as follows: First, as for the correlation of disaster perception, satisfaction and volunteering continuity, perception of disaster countermeasures, satisfaction and the level of participation were negatively correlated with one another, and there was a positive correlation among disaster training, disaster preparation, regional disaster, the period of volunteering, and will of persistent volunteering. Second, as for perception of disaster, the volunteer fire-fighters were asked a question about disaster countermeasures, and the largest group replied they were partially aware of the countermeasures. Concerning questions about disaster training/education experience and triage, the biggest group replied they underwent the training and knew about triage on the whole. Regarding questions on the emergency contact system and emergency work schedule, they knew about the two in general. As to a question on the occurrence of human disaster, the greatest group answered that they knew about it yet not well. Third, in regard to the impact of satisfaction level on volunteering continuity, the period of volunteering was affected by needs for experience, social contact and social recognition among the subfactors of satisfaction level, and will of persistent volunteering was under the influence of social contact and achievement needs. The level of persistent volunteering was affected only by needs for experience and achievement needs.

Study on Theoretical Research to Reduce Fire Risk of Solar Power System (태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Guen-Cull;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

An Empirical Study on Firefighters' Health Hazard Factors -Focused on Fire Fighters, Rescue Workers and Emergency Medical Technicians Perception in Busan Fire Fighters- (소방공무원 건강장해 유해인자에 대한 실증연구 -화재진압대원, 구조대원, 구급대원의 인식조사를 중심으로-)

  • Kwon, Seol A;Lee, Min-Kyu;Park, Sang Ho;Kim, Da Young;Ryu, Sang Il
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.520-529
    • /
    • 2019
  • This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. Moreover, the danger of shift work was perceived the most by paramedics. This corresponds to the existing studies arguing that shift work is harmful to health. Next, the overload of patient transport was recognized as the second biggest hazard factor. This demonstrates they are worried about various second accidents that may happen due to a lot of patient transport works. In addition, the possibility of causing a traffic accident was perceived as a hazard factor too, since they must drive ambulance cars quickly to transport patients. Lastly, rescue workers regarded these hazard factors to be most dangerous. This is associated with their occupational characteristics, because rescue workers are the closest to diverse risks including a fire.

A Study on the Method of Resistance Analysis of Water Stream During Fire Supperession (화재진압 시 발생하는 주수 기둥의 저항분석 방법 연구)

  • Jung, Byeong-Sun;Kim, Eung-Sik;Park, Jong-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.22-27
    • /
    • 2018
  • Fire fighters are exposed to the risk of many accidents during fire suppression, especially near the high voltage circuit. In order to prevent and analyze the electric shock accidents, measurement of water resistance is crucial. However, this has been one of the overlooked research areas and it has been very difficult to measure the mixed up resistance components separately. In this paper, we measured a total resistance of apparatus and regarded it as a serial resistance of contact resistance and length dependant resistance. Measuring the resistance by varying the length of water stream, the variable resistance and fixed contact resistance appear, which are used to calculate the both components of resistances. In addition, the resistance of fire hose can be calculated from the parallel circuit which is formed by grounding the fire hose with the resistance of water stream. Results show that we can successfully measure the resistance per unit length of water stream and fire hose, thereby proving that this method is a facile way to measure water and fire hose resistance. However, many experiments are still required to obtain the precise contact resistance of ground under various condition and the resistance between the human body and fire hose.

An Study of Pressure Variations in Smoke Control on Protected Escape Routes Using Pressurization (급기가압 제연 시 전실 내 압력변화에 관한 연구)

  • Kim, Hong-Sik;Oh, Dae-Hee
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.247-250
    • /
    • 2008
  • Pressurization is a method of ensuring that protected escape routes(staircases and lobbies) are kept free of smoke for shelterers and fire fighters by raising the air pressure in these spaces above that in the main part of the building. In this study, to estimate a pressurization, the characteristics of pressure difference in a room, a lobby, an air supply shaft at several building elements are investigated with a window, the (a fire) door and a air supply damper so that information about the importance of these experimental parameters can be obtained.

  • PDF

A Study on the Fire Organization of the Effectiveness Life Safety Services (소방조직의 효과적인 생활안전서비스에 관한 연구)

  • Chae, Jin;Woo, Seong-Cheon;Go, Gi-Bong
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.47-55
    • /
    • 2013
  • The importance of fire safety services has increased expanding its services into prevention of danger and the reinforcement of safety services. The purpose of this study is to suggest a way for effective safety service by surveying fire fighters and residents of Gyeonggi Province and examining theories of safety services and actual status of 119 safety units. This study suggests the use of social capital by local community, establishment of cooperation between organizations, supports by citizens, cooperative activities by organizations, difference between emergency report and non emergency report and social safety net role of safety fire services.

Survey on a Research for Fire Safety in Space with the Understanding of Combustion Characteristics in Microgravity based on NASA's Space Research Program (NASA의 우주 연구 프로그램에 따른 미소 중력하에서의 연소 특성 및 화재 안전 연구 개괄)

  • Sohn, Chae-Hoon;Son, Young-Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.3
    • /
    • pp.65-72
    • /
    • 2007
  • Fire is one of important checkpoints in crewed exploration systems, where men inhabit in space. In space, astronaut can't escape from fire out of a spacecraft and not expect any help of fire fighters, either. Accordingly, the best way to stand against fire is to prevent it. But, when fire occurs in space, flame behaviors are quite different from those observed on earth because of micro- or zero-gravity in space. The present paper introduces major research results on flame behaviors under microgravity and fire prevention, detection, and suppression in crewed exploration spacecrafts and international space station based on NASA's FPDS research program.