• 제목/요약/키워드: Fire Fighters

검색결과 142건 처리시간 0.027초

실내화재진압로봇의 현장운용 및 소화성능평가 (Field working and Fire extinguishing performance of an Indoor Fire-fighting Robot)

  • 곽지현;김종권
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.163-167
    • /
    • 2008
  • Fire-fighters are struggling against heat and dense smoke by fire when it occurs at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to evaluate field working ability of the fire-fighting robot. As a result, a series of passing obstacles, finding fire place and fire suppression by the remote controlling with image information appeared satisfactory.

  • PDF

실내화재진압로봇의 현장운용성 향상을 위한 실용성 평가 (Evaluation of Field working Improvement for an Indoor Fire-fighting Robot)

  • 곽지현;이우준;김종권
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.126-131
    • /
    • 2008
  • Fire-fighters have been struggling against heat and dense smoke caused by fire when it occurs especially at the basement or the inner place of a building. An indoor fire-fighting robot with well heat-resistance, great searching cameras and good extinguishing ability has been recently developed. It never suffocate, coming into the fire district and extinguishes fire directly. In this study, several experiment was conducted to promote field working ability of the fire-fighting robot. As a result, heat resistance, water discharge and field working appeared satisfactory.

  • PDF

NUMERICAL SIMULATION OF WIND-DRIVEN FIRE FLUMES

  • Kohyu Satoh;Yang, K.T.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.327-334
    • /
    • 1997
  • In many large urban-fire scenarios one of the critical issues is to attempt to protect the lives of fire fighters in helicopters deployed to flying over the fires and also the lives of people trapped in open areas downwind of the fires such as in parks. The strategies of such protection measures depend significantly on our knowledge of the size and extent of such fires as affected by the prevailing winds. In this study, the shape or profile of the fire plume typical of large urban fires, as affected by a steady unidirectional wind with or without imposing a shear flow on the fire plume, has been simulated numerically by a field model. The results show that the simulations provide realistic flame profiles and at least qualitatively, the same flame dynamics when compared to those from the experiments, and that the fire plumes are sensitive to small variations in the asymmetry of the wind shears, including the appearance of swirling flames within the fire plumes.

  • PDF

소방보호복 소재의 공기간극이 열보호 성능에 미치는 영향 (Effect of Fire Fighters' Turnout Gear Materials Air Gap on Thermal Protective Performance)

  • 이준경;권정숙
    • 한국화재소방학회논문지
    • /
    • 제28권4호
    • /
    • pp.97-103
    • /
    • 2014
  • 소방보호복은 고열유속에 의한 화상방지를 위해 3층 이상의 복합소재로 구성되어 있으며, 각 소재 사이는 공기 간극이 존재한다. 화재에 의한 고열유속 노출 시 공기 간극 내에서의 열전달은 대류와 복사에 의해 주로 발생하며, 그로 인해 간극의 크기에 따라서 비선형 특징의 열 저항 크기를 갖게 된다. 그러므로 본 연구에서는 보호복 소재 사이의 여러 가지 공기 간극(0~7 mm)에 대한 보호복의 열 보호성능을 자세히 파악하기 위한 실험을 수행하였다. 복사 열 유속 입사시에 시간에 따른 각 소재의 온도 변화뿐만 아니라, 열 보호성능을 가장 효과적으로 나타낼 수 있는 지표(Radiant Protective Performance, RPP) 값의 공기간극에 대한 변화 특성을 파악하였다. 공기간극이 증가할수록 단열효과가 커짐으로 인해 후면의 온도는 낮아지고, RPP는 커짐을 확인할 수 있었다. 특히 일정 열유속 조건에서 공기간극에 대한 RPP 값은 선형적인 특성을 나타내었고, 그러한 결과를 바탕으로 다양한 입사 열유속 및 공기 간극 조건에 대해 비교적 간단한 형태의 RPP 지표 예측 식을 제안하였고, 좋은 예측 결과를 얻을 수 있었다.

서울재난관리조직에 대한 재난관리공무원간의 인식비교분석 (The Comparison Analysis of Recognition about Disaster Management Organization of Seoul between Fire Fighters and Regular Officers)

  • 송윤석
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.154-164
    • /
    • 2009
  • 우리나라 광역자치단체는 1990년대 이후에 복합재난발생, 소방업무의 중요성 등으로 자연재난관리 및 인적재난관리 업무를 담당하는 조직을 소방본부로의 완전통합 및 부분통합시키고 있는 현실이다. 따라서 재난관리업무를 담당하는 소방직과 일반직공무원간의 관계는 더욱 중요해지고 있다. 이에 본 연구에서는 재난관리조직의 관리역량, 인명활동, 재난, 업무효율 등에 대한 설문지를 구성하여 서울특별시 재난관리조직에서 근무하는 공무원을 대상으로 설문조사를 실시하여 소방직과 일반직공무원간의 인식비교분석을 하였다. 인식비교분석결과 관리역량의 시설, 재난의 인적재난, 업무효율의 업무협조성, 업무연계성 등이 유의미한 차이가 발생하였다. 이러한 인식비교분석을 통하여 서울특별시 재난관리조직의 개선방향에 대해서 제시하고자 하였다.

고온가열 콘크리트의 강도 특성과 현상 (Strength Characteristic and Phenomenon of Heated Concrete by High Temperature)

  • 태순호;이병곤
    • 한국안전학회지
    • /
    • 제12권3호
    • /
    • pp.132-138
    • /
    • 1997
  • For many years concrete has been the major building material for most construction. It is of primary importance that fire fighters or fire investigators have a full understanding of the properties of concrete so that better control of the fire scene is achieved. This, in turn, not only help to ensure a safer fire-fighting job but also a more successful fire investigation. So far as the fire scene investigation in concerned, knowledge about the thermal behaviour of concrete can help the investigators to determine the highest temperature that a particular spot of a fire scene has ever reached thereby providing data which may be of value in reconstructing the course of the fire.

  • PDF

서울종합방재센터 종합상황실 소방공무원의 감정노동이 조직몰입에 미치는 영향 - 사회적 지원의 매개효과를 중심으로 - (The Influence of Emotional Labor at Seoul Management Operations Center on Job Performance : Focusing on the Mediating Effect of Social Support)

  • 박찬석;김진근
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.13-25
    • /
    • 2015
  • In recent years, the surroundings of Fire have rapidly changed and citizens need for Fire have been demanding very high. Under these situations, in order for satisfaction to all these demands, Seoul Emergency Operations Center have made improvements as the core fire operational center in Korea. However, There have been so many problems happening in the middle of receiving calls from malice citizens of Seoul. The purpose of this study is to scrutinize current operations focused on fire fighters in Seoul Emergency Operations Center and to cope with how to overcome these problem by using AMOS 21 & SPSS Statistics 21. The result of this study presents that how we can find to be Seoul Emergency Operations Center running well. And This study is applied to seoul fire policies or helped to setting them up.

소방취약지 모델의 구성과 정립프로세스 논의 (Discussion on Formulation Process and Configuration of Fire-Fighting Vulnerable Zone Model)

  • 김성곤;장은미;최갑용;김희태
    • Spatial Information Research
    • /
    • 제22권3호
    • /
    • pp.71-77
    • /
    • 2014
  • 화재, 폭발 등의 재난현장은 예측할 수 없는 수많은 위험 요소들이 존재하고 있으며 촌각을 다투는 인명 구조나 초기에 불길을 잡지 못하면 막대한 피해로 이어지는 특성을 가지고 있다. 특히, 출동 후 5분이내 현장에 도착하는 소방대원은 제한적인 정보와 즉각적인 현장 투입으로 인해 사고 현장의 상황을 충분히 인지하며 임무를 수행하는데 한계가 있어 효율적인 작전 수립 및 전개에 어려움이 발생하고 있으며 우발적인 상황 대처로 소방대원 스스로의 생명을 위태롭게도 한다. 이와 같은 한계 및 위험을 경감시키며 효율적인 진압 및 구조 활동을 전개하기 위해서는 우선적으로 사고 현장 및 환경에 대한 상황 정보를 효율적으로 인지하고 활용 할 수 있도록 하는 도구가 제공되어야 한다. 기존 국내외 연구는 주로 대형 화재와 같은 재난이 발생할 경우 인명 및 재산 피해가 예상되는 공간적 영역에 대한 화재취약성 관점에서의 연구가 주로 수행되었으며 소방 활동 관점에서의 공간적 취약성을 분석하고 이에 대한 대응 방안을 연구한 사례는 매우 드문 실정이다. 이에 본 연구에서는 화재 진압을 위한 소방 활동에 초점을 맞추어 출동에서부터 진압 구조까지의 소방 활동 전주기를 대상으로 소방 활동 저해 요인을 종합적으로 분석할 수 있는 소방취약지 모델을 개발하였다. 또한, 기존 연구의 화재 취약 공간과 본 논문에서 제시하고 있는 소방 취약 공간에 대한 개념을 명확히 하기 위해 소방취약지에 대한 개념을 정립하고 소방취약지 모델의 목적성 및 적용성을 구체화 하였다. 본 연구 결과는 전국 시도 소방본부 관할구역에 대한 소방취약지 유형 분석, 소방 활동 성능 개선을 위한 정책 수립 및 의사 결정 과정에 적용될 수 있을 것으로 판단된다.

축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구 (The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance)

  • 한용택;나병균;최진성;민세홍
    • 한국화재소방학회논문지
    • /
    • 제31권5호
    • /
    • pp.63-69
    • /
    • 2017
  • 본 연구에서는 초고압 펌프의 개발과 같이 사용할 수 있는 초고압용 장거리 호스 개발에 관한 연구이며, 접근과 방수거리의 도달이 어려운 초고층 건물 및 대심도 터널의 화재진압에 효율적으로 적용이 가능함과 동시에 축광 성능을 포함하여 소방관의 화재 진압 시 퇴로 확보에도 도움이 될 수 있는 초고압용 호스의 개발에 관한 연구이다. 호스의 성능으로서 압력 3 MPa, 유량 2000 lpm을 목표로 초고압 호스를 개발하였으며, 2중의 자켓과 3중의 폴리우레탄 코팅 및 52의 경사를 사용하여 매우 촘촘하고 높은 고압에도 견딜 수 있는 초고압 소방호스를 개발하였다. 개발된 초고압 호스의 성능을 확보하기 위하여 구조 및 외관, 고압에서의 누수, 길이, 신장률, 박리시험, 마찰시험, 파단압시험 및 자유낙하 시험 등이 공인된 인증기관에서 수행되었으며 수행결과 성능에 이상이 없는 것으로 파악되었다. 또한 소방관의 화재진압 시 퇴로를 확보하기 위한 축광 성능의 초고압 호스에 추가하여 연구 및 개발하였으며, 휘도시험의 값으로 축광의 발광시험 개시부터 40분 후까지 휘도 측정치가 휘도시험의 기준 값 이상으로 충분히 확보되는 것을 확인할 수 있었다. 향후, 이와 같은 초고압용 소방용 호스가 상용화가 되어 현장에서 적용된다면 초고층 건물의 화재진압 및 장대터널에서의 화재진압에 있어서 현재 사용되고 있는 소방호스 보다 개선된 화재 진압 및 안전한 퇴로를 확보하는 측면에서 기여할 수 있을 것으로 판단된다.

소방안전교부세의 운영 및 개선방안에 관한 연구 (Study on the Management and Improvement Methods of Fire Safety Shared Tax)

  • 장중돈;이종호
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.117-125
    • /
    • 2018
  • 본 연구는 소방재원인 소방안전교부세가 교부된 후 사업 선정 및 운영 등의 인식에 관한 문제점을 도출하고 그에 대한 개선방안을 제시하는 데 있다. 이를 위해서 소방안전교부세의 세부 사업운영 인식, 사업집행 만족도, 재정 운영방안에 관련한 내용을 소방공무원을 대상으로 설문조사한 결과, 소방안전교부세 운영에 있어 소방공무원들은 소방안전교부세의 세부사업분야, 투자내용 등에 관한 관심이 소홀한 것으로 나타났다. 교부세 집행 후의 만족도에서는 소방장비에 대한 노후율 감소 및 보급률 향상은 소방장(M = 3.70)과 16년 이상(M = 3.64)의 재직기간에서 높은 것으로 나타났다. 재정의 개선방안에 있어서 국고보조금의 감소가 부적절하다는 의견이 많았다. 제한적으로 운영되고 있는 소방안전교부세 사업의 다변화 및 개발과 함께 국고보조금 사업이 안전분야 사업과 대부분 중복되고 있어 부족한 소방재원을 안정적으로 확보하기 위해 교부세 전액을 소방분야에 투자될 수 있도록 법제도적 개선이 필요하다.