• Title/Summary/Keyword: Fire Factor

Search Result 538, Processing Time 0.031 seconds

Analysis of traffic accidents involving 119 emergency (119 구급대 구급차 교통사고 현황 분석)

  • Lee, Jeong-Ho;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.22 no.1
    • /
    • pp.35-47
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate both the occurrence status of emergency vehicles traffic accidents and contents of the experiences of emergency medical technicians (EMTs) in fire station. Methods: A self-reported questionnaire was completed by 451 EMTs in fire stations in 6 cities provinces from February 9, 2017 to February 27, 2017. Results: Of 451 EMTs, 207 (45.9%) had traffic accidents experience. Regarding environment-related features, results indicated hour (12~18 hours), place (national highway), traffic flow (smooth), weather (clear), season (winter), and day (Friday). Regarding correlation analysis of differences in the number of ambulance traffic accidents pursuant to general features of accident-experienced drivers as a human factor, there were no significant differences in recruitment, driving careers of regular cars, driving careers of fire engines, and class but there were significant differences in fire-fighting careers. Accident experience in the group with careers over 6 years and less than 10 years higher than in the other groups. Conclusion: Efforts to expand fire engine driving education programs for the prevention of traffic accidents involving 119 emergency vehicles are required.

Fire Resistant Regulation Status and Activation Plan of Domestic Modular Construction (국내 모듈러 건축의 내화구조 제도 현황 및 활성화 방안)

  • Choi, Yun-Jeong;An, Jae-Hong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.673-680
    • /
    • 2022
  • Modular construction is recognized as a construction method with various advantages, such as shortening the construction duration, achieving quality control through factory production, ease of maintenance, and reduced construction costs due to reduced weight of materials. However, despite efforts by the modular industry and government to activate modular construction, it has rarely been established in the domestic market. Currently, there are technical limitations to the modular construction fire resisting technology applied to general buildings. The lack of access to modular construction fire resistance regulation is considered a major factor. In this study, the current status and problems with modular construction fire resistance regulation, a significant hindrance factor, were considered to activate modular construction. This study is intended to present a direction for institutional improvement in modular construction fire resistance and a direction for research and development.

The comparative study on changes in turnover intention according to the level of Burn out and the convergence mediating factors in fire officer

  • Ji, Dong-Ha;Choi, Mi-Suk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.111-117
    • /
    • 2016
  • The purpose of this study is to analyze the changes in turnover intention according to the level of Burn out and the mediating effect in fire officer. Higher levels of emotional labor and turnover intention resulted in higher levels of burn out(p<0.05). We used the logistic regression analysis to compare change of turnover intention according to the level of burn out. In logistic regression analysis, largest mediating factor were working days per week, the number of moving case per a day, physical condition, emotional labor and the odds(Likely to with high turnover intention) was down by 38.9% after adjustment for mediating factors. The results of this study indicate that emotional labor was negatively impact on burn out in fire officer. To reduce the burn out and the turnover intention, it is necessary to do more efforts to improve work environment (working days per week, the number of moving case per a day and emotional labor) and management personal factor(physical condition) for the fire office should be made to reduce such negative effects.

The research on changes in turnover intention due to the degree of occupational stress and the mediating parameters in fire-officerse Mice

  • kang, Kwang Soon;Ji, Dong Ha
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.7
    • /
    • pp.109-115
    • /
    • 2017
  • This study was performed to investigate the changes in turnover intention according to the level of occupational stress and to find the mediating factor that reducing the turnover intention among fire officer. To compare change of turnover intention according to the degree of occupational stress, statistical analyses were done by using the logistic regression model. In logistic regression analysis, the possibility of high turnover intention in a group with high occupational stress was hjgher by 4.11 times than a group with low occupational stress. The results of analyzing the degree of change in turnover intention after applying the mediating parameters(physical condition, emotional labor, burn out), turnover intention decreased by about 50.6%(from 4.11 times to 2.03 times) at the high level of occupational stress. As a result, it was found that the occupational stress experienced by the fire-officers had a positive effect on the turnover intention. In order to reduce the turnover intention due to the occupational stress of the fire-officers, it is necessary to manage factors such as work environmental factors(emotional labor, burn out) and individual factor(physical condition).

A Study on the Fire Resistance Design of Buildings Considering the Fire Load Energy Density (화재하중밀도를 고려한 건축물의 내화설계법에 관한 연구)

  • 이평강;이용재;최인창;김회서
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.10-16
    • /
    • 2003
  • The main purpose of this study is to raise the point at issue and to propose reform direction about the current performance criteria of fire resistance through the examination of the fire resistance required for each use of compartment by using performance-based fire safety design method. To examine the performance criteria of fire resistance, this study compared the equivalent time of fire exposure which was calculated by using time-equivalent formulae with the required fire resistance time determined by existing prescriptive code, and surveyed factors such as the fire load energy density, ventilation factor, fire compartment materials and fire compartment geometry in order to calculate the equivalent time of fire exposure.

Forest Fire Risk Zonation in Madi Khola Watershed, Nepal

  • Jeetendra Gautam
    • Journal of Forest and Environmental Science
    • /
    • v.40 no.1
    • /
    • pp.24-34
    • /
    • 2024
  • Fire, being primarily a natural phenomenon, is impossible to control, although it is feasible to map the forest fire risk zone, minimizing the frequency of fires. The spread of a fire starting in any stand in a forest can be predicted, given the burning conditions. The natural cover of the land and the safety of the population may be threatened by the spread of forest fires; thus, the prevention of fire damage requires early discovery. Satellite data and geographic information system (GIS) can be used effectively to combine different forest-fire-causing factors for mapping the forest fire risk zone. This study mainly focuses on mapping forest fire risk in the Madikhola watershed. The primary causes of forest fires appear to be human negligence, uncontrolled fire in nearby forests and agricultural regions, and fire for pastoral purposes which were used to evaluate and assign risk values to the mapping process. The majority of fires, according to MODIS events, occurred from December to April, with March recording the highest occurrences. The Risk Zonation Map, which was prepared using LULC, Forest Type, Slope, Aspect, Elevation, Road Proximity, and Proximity to Water Bodies, showed that a High Fire Risk Zone comprised 29% of the Total Watershed Area, followed by a Moderate Risk Zone, covering 37% of the total area. The derived map products are helpful to local forest managers to minimize fire risks within the forests and take proper responses when fires break out. This study further recommends including the fuel factor and other fire-contributing factors to derive a higher resolution of the fire risk map.

Prediction of the Fire Behavior According to the Fire Load in an Underground Life Space (화재하중에 따른 지하생활공간의 화재성상 예측)

  • Chae, Han-Sik;Suk, Chang-Mok;Kim, Ie-Sung;Lee, Ji-Hee;Kim, Wha-Jung
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.51-59
    • /
    • 2007
  • The purpose of this study is analyzing the fire behavior according to the fire load for G underground shopping mall located in Daegu city. when predict fire behavior, fire load and ventilation coefficient are important factor who dominate fire temperature or fire continuance time. Therefore, size of unit room, opening size and inflammable investigated on the field. Fire load calculated using unit calorific value by each material of inflammable that investigate. And reduction model experimented fire load about 6 models with variable. Fire behavior analyzed by heat flows of inside space that temperature rise and temperature change by time of fire source.

An Empirical Study on Firefighters' Health Hazard Factors -Focused on Fire Fighters, Rescue Workers and Emergency Medical Technicians Perception in Busan Fire Fighters- (소방공무원 건강장해 유해인자에 대한 실증연구 -화재진압대원, 구조대원, 구급대원의 인식조사를 중심으로-)

  • Kwon, Seol A;Lee, Min-Kyu;Park, Sang Ho;Kim, Da Young;Ryu, Sang Il
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.3
    • /
    • pp.520-529
    • /
    • 2019
  • This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. This study is intended to provide basic data for health management of firefighters in the future by empirically looking into health hazard factors of firefighters in Busan City. It was revealed that firstly, the danger of harmful chemicals in a fire was perceived the most by firefighters, who extinguish a fire in person on the scene of a fire, and it was followed by the danger of falling while putting out a fire. Moreover, the danger of shift work was perceived the most by paramedics. This corresponds to the existing studies arguing that shift work is harmful to health. Next, the overload of patient transport was recognized as the second biggest hazard factor. This demonstrates they are worried about various second accidents that may happen due to a lot of patient transport works. In addition, the possibility of causing a traffic accident was perceived as a hazard factor too, since they must drive ambulance cars quickly to transport patients. Lastly, rescue workers regarded these hazard factors to be most dangerous. This is associated with their occupational characteristics, because rescue workers are the closest to diverse risks including a fire.

Study of Standard Design Fire Curve of Various Railcar (철도차량별 표준 설계화재곡선 연구)

  • Lee, Duck-Hee;Park, Won-Hee;Jung, Woo-Sung;Kim, Chi-Hun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1426-1431
    • /
    • 2011
  • A study on the standardization of design fire HRR(heat release rate) curve was conducted for various railcar from the fire simulation or the fire tests. These standard curves are listed on the tunnel fire safety manual which will be used for the QRA(quantitative risk analysis) process of the long railway tunnels. The design fire curve is based with four simple factor representing the key of fire curve characteristics. Flashover time, maximum HRR and burn out time are the key factors of the design fire curve. Specially total heat release is decided by the burnable material amount in the car.

  • PDF

Fire Simulations for the Abandonment Risk Assessment of Main Control Room Fire in Domestic Nuclear Power Plant (국내 원자력발전소의 주제어실 화재 피난 리스크 평가를 위한 화재 시뮬레이션)

  • Kang, Dae Il;Kim, Kilyoo;Jang, Seung-Cheol;Yoo, Seong Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.199-207
    • /
    • 2014
  • In this paper, to systematically assess the abandonment risk of main control room (MCR) fire, fire simulations with Fire Dynamics Simulator were performed and abandonment probabilities were estimated for the MCR bench-board fire of domestic reference nuclear power plant. The fire simulation scenarios performed in this study included propagating and non-propagating fires of the MCR bench-board, and the availability and unavailability of heating, ventilation, and air conditioning system (HVACS). The following results were obtained. First, temperature was the major abandonment impact factor for the MCR bench-board fire if the HVACS was available and optical density was that if the HVACS was unavailable. Second, the fire scenario contributing the MCR bench-board fire abandonment risk was identified to be only the propagating fire. Third, it was confirmed that the abandonment probability of the MCR bench-board fire for domestic reference nuclear power plant could be reduced by using the fire modeling.