• 제목/요약/키워드: Fire Extinguishing Agents

검색결과 54건 처리시간 0.021초

헵탄 풀화재에서 불활성기체 소화농도 (Extinguishing Concentration of Inert Gases in Heptane Pool Fires)

  • 정태희;이의주
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.71-76
    • /
    • 2012
  • The coflow velocity effect on the minimum extinguishing concentration(MEC) was investigated experimentally in heptane cup-burner flames. Various inert gases($N_2$, Ar, $CO_2$, He) were added into the oxidizer to find the critical concentration and the effectiveness of the agents on flame extinction. The experimental results showed that the MECs were increased with increasing coflow velocity for most inert gases except helium, but the higher coflow velocity induced the lower burning rates of heptane. This indicated that the increase of coflow velocity resulted in the decrease of fuel velocity evaporated from fuel surface, and hence the stain rate on the reaction zone was also decreased. In the case of helium as a additive, the extinguishing concentration was independent of the coflow velocity because the heat conductivity was ten times larger than the other inert gases and flow effect by a strain rate might be compensated for heat loss to the surroundings.

첨가제가 혼합된 미세물분무의 소화성능에 관한 연구 (A Study on the Extinguishing Performance of Water Mist with Additives)

  • 이경덕;신창섭
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 2002
  • 할론 소화약제는 오존층파괴지수와 지구온난화지수가 높아 환경문제를 야기하며, 이의 대체기술의 일환으로 미세물분무에 대한 관심이 집중하고 있다. 미세물분무에 대한 연구로는 적용화재에 보다 효과적인 소화를 위한 최적의 물입자를 만들려는 연구와 함께 첨가제를 이용하여 미세물분무의 소화성능을 향상시키기 위한 연구가 진행되고 있다. 본 연구는 이전 연구$^{1)}$ 에서 제시한 순수한 미세물분무의 입자크기, 방사분포 및 화염크기에 따른 ethanol과 n-heptane 화염의 진압특성과 소화시간에 대한 연구를 기반으로, 여기에 미세물분무의 물리적 소화성능의 향상과 화학적 소화성능을 부여하기 위해 첨가제를 첨가하였을 때의 성능을 평가하고 최적의 조건을 구하고자 하였다. 실험결과, ethanol panl 화염에 7N3노즐을 4kg/$\textrm{cm}^2$로 방사한 경우 0.3% AFFF와 2.5wt% NaCl를 첨가한 미세물분무는 순수한 미세물분무 보다 27%와 60% 빠른 소화시간을 나타냈다. AFFF의 첨가는 연료표면 위에서 얇은 막을 형성하여 화염으로부터 연료 표면으로 되돌아오는 열을 감소하므로 연료표면에서의 화염온도 감소와 함께 n-heptane 연료의 증발을 감소함으로서 소화가 이루어지는 것으로 판단되며, 또한 알칼리 염인 2.5wt% NaCl을 첨가한 경우 화염면에 알칼리염 결정체가 형성되는 현상이 나타났다.

Halon 1301과 Halon 대체 소화약제를 기포제로 이용한 포 소화약제에 대한 연구 (A Study On The Application Of Foam Extinfuishing Agent By Using Halon 1301 And Halon Alternatives)

  • 정기창;임성묵;이창섭;강영구;김홍
    • 한국화재소방학회논문지
    • /
    • 제10권3호
    • /
    • pp.29-40
    • /
    • 1996
  • 포 소화약제는 물보다 비중이 가벼운 액체 가연물 또는 입체면이 많은 건물에서 포 수용액을 팽창 발포시켜 대상물을 덮어 씌우거나 봉쇄해서 질식소화 시킬 수 있다. 포 소화약제로 소화성능이 탁월한 수성막포(AFFF) 소화약제를 노즐에 의해 공기와의 혼합으로 포를 형성하는 기존의 방법과 다른 방법으로 본 연구에서 는 Halon 1301 및 Halon 대체 소화약제를 기포제로 사용하여 소화성능과 팽창비를 향상시킨 소화약제를 개발하게 되었다. 개발한 Halon 1301과 Halon대체 소화약제를 기포제로 사용한 수성막포 소화약제는 적은 양의 수성막포 수용액으로 많은 양의 포를 형성하므로 휴대용 포 소화기 또는 포 소화설비 등에 유용하게 사용할 수 있다.

  • PDF

개구부 면적이 $CO_2$ 소화설비의 소화성능에 미치는 영향 -기계실 석유 표면화재의 CFD simulations- (The Effects of the Area of Openings on the Performance of a $CO_2$ Extinguishing System -The CFD Simulations of the Oil Surface Fire in a Machine Room-)

  • 전흥균;최영상;박종탁
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.1-9
    • /
    • 2008
  • 이산화탄소는 다른 어떤 가스계 소화약제보다도 화재를 안전하게 진압하는 소화약제로서 다양한 방호구역과 화재에 대하여 널리 사용되고 있다. 성능위주설계 개념에 따라 이산화탄소 소화설비는 설계 단계에서 해당 방호구역의 발생 가능한 화재시나리오에 따라 소화성능을 확인할 필요가 있다. 본 연구에서는 $100m^3$의 체적을 갖는 기계실의 석유 유출(설계)화재시 개구부의 크기가 $CO_2$ 소화설비의 소화성능과 유동장의 유동특성에 미치는 영향을 조사하기 위하여 CFD 시뮬레이션을 수행하였다. 소화완료 시간은 개구부의 면적 크기에 비례하여 증가하였고, 3가지 화재모델의 소화완료 시간 모두 $CO_2$ 소화설비의 성능기준에 부합하였다. 개구부의 질량 유동율은 화재 열방출과 $CO_2$ 소화약제 분사의 복합적인 작용에 의해 영향을 받았다. $CO_2$ 소화약제 분사 완료 후 방호구역의 산소농도는 화재모델 모두 연소한계산소농도 보다 적었다.

NOVEC가스 소화설비용 노즐 형상 설계에 대한 수치해석 (Numerical Analysis on Development of Nozzle Shape for NOVEC Gas Extinguishing System)

  • 윤정인;정경국;김지성;김성윤;노범석;최재혁
    • 해양환경안전학회지
    • /
    • 제24권7호
    • /
    • pp.939-944
    • /
    • 2018
  • 청정소화약제는 지구오존층 보호를 위해 발효된 몬트리올 의정서에 따라 할론 1211 및 할론 1310을 대체할 수 있는 약제를 말한다. 국 내외적으로는 청정소화약의 시스템 표준화와 성능평가가 수행되고 있다. 본 논문은 일반적인 청정소화약제 시스템을 바탕으로 다양한 노즐의 형상에 대한 모델링 및 수치해석을 수행하여 최적의 노즐 형상을 제안하였다. Type A와 B의 2가지 형상에 대한 노즐의 3차원 모델링을 통해 노즐의 분출속도가 개선될 수 있도록 하였다. 2가지 형상의 노즐에 대하여 유동해석을 실시하였으며 노즐의 홀 직경을 다르게 하여 가스속도 및 압력분포를 측정하였다. 측정결과 노즐 홀 수 및 직경에 따라 노즐출구에서 분출속도가 달라지는 것을 확인 할 수 있었으며 노즐 홀 직경에 관계없이 유량은 압력이 증가함에 따라 증가하는 경향을 나타내었다. 실험을 통해 얻어진 결과를 바탕으로 노즐 직경이 5 mm인 경우의 K-factor값이 $101.8l/min{\cdot}bar^{-0.5}$임을 확인하였으며, 최종적으로 노즐 홀 5 mm인 12개의 홀이 2층 구조로 되어 있는 형상의 노즐을 제안하였다.

태양광 접속반의 자동 화재 예방 및 진압 시스템 설계 (Design of Automatic Fire Prevention and Suppression System for Photovoltaic Connection Module)

  • 이강원;양오
    • 반도체디스플레이기술학회지
    • /
    • 제21권3호
    • /
    • pp.33-38
    • /
    • 2022
  • A solar power generation system uses a solar module that collects solar radiation energy, a connecting board that collects DC power generated from the solar module, and a diode to prevent reverse current from flowing from an inverter to the solar module. The existing photovoltaic connection module consists of only fuses and diodes for reverse polarity and overcurrent blocking, and does not have fire diagnosis, prevention, and suppression functions in the event of a fire. To solve this problem, this paper presents a method to monitor the internal state of the photovoltaic connection module using several sensors and to prevent and extinguish a fire using solenoid valves and fire extinguishing agents when a fire is detected. Through the experiment, it was confirmed that the proposed method normally suppresses the fire in event of a fire.

가스계 소화시스템관련 안전기술 (A Technical Description on The Safety Aspects related To Gas Suppression Fire Protection System)

  • 이창욱
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2002년도 춘계학술대회 논문집
    • /
    • pp.21-29
    • /
    • 2002
  • 가스계 소화약제시스템의 인명안전 또는 기타 안전관련으로 CO2 시스템과 청정약제시스템을 중심으로 기술해보았습니다. 인명에 대한 위험을 최소화하면서 CO2 소화시스템의 혜택을 얻기 위해서는 설계, 시공, 유지관리면에서의 인명안전에 대해 상당한 관심을 기울여야한다. 청정 소화약제를 통상의 거주구역에 사용할 경우의 주요요소는 독성문제이다. 할로겐화탄소약제 테스트에서의 주요 관점은 급성효과, 즉 단기간 노출의 경우이다. 주요급성효과에는 마취성과 심장감작성이 있다. 불활성가스약제의 경우 주요 신체적 영향으로는 산소농도의 저하문제를 들 수 있다.

  • PDF

금속화재 위험감소 방안에 관한 이론적 연구 (Study on the effective response method to reduce combustible metal fire)

  • 남기훈;이준식
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.600-606
    • /
    • 2018
  • 금속화재는 나트륨(Na), 리튬(Li) 등과 같은 가연성 금속이 연소하는 화재이다. 일반적인 물계, 가스계 소화약제에는 적응성이 없으며 금속화재용 소화약제 또는 건조사로 화재를 진화할 수 있다. 위험물안전관리법상 가연성 금속에 속하는 2류 및 3류 위험물 화재가 최근 5년간 104건이 발생했으며, 가연성 금속을 사용하는 연료전지, 반도체 산업의 발전으로 화재 건수는 더욱 증가할 것으로 예상되고 있다. 하지만 국내에는 금속화재와 관련된 법적 기준이 마련되어 있지 않아 금속화재용 소화약제 및 소화기 개발은 물론 화재 예방 및 대응 시스템 구축이 이루어지지 않고 있다. 이에 본 연구에서는 금속화재의 위험성을 감소시킬 수 있는 방안을 마련하기 위해 국내외 관련 법령 분석 및 금속화재 사례 11건을 분석하였다. 이를 통해 금속화재의 위험성을 감소를 위해 관련 법령 마련에 필요한 요소를 도출하였으며 금속화재 발생 시 소화약제로 사용되고 있는 건조사의 관리 및 지원방안을 제시하였다. 또한, 금속화재의 예방 및 대응에 필요한 안전교육 및 시설 관리 방안을 제시하였다.

계면활성제 첨가에 따른 함수율에 관한 실험적 연구 (Experimental Study on Moisture Content According to Addition of Surfactants)

  • 김남균;이동호
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.79-83
    • /
    • 2015
  • 화재사고는 그 충격과 영향이 업무중단 및 기업의 존폐를 좌우 할 수 있는 대표적인 재난 유형이다. 따라서 사전 예방, 대비는 물론 재난 발생 시 신속한 초기대응이 매우 중요하다. 현재 운용되고 있는 저탄장 및 합판 가공 산업 분야 등에서는 다공성 가연물의 저장이 불가피하다. 다공성 가연물 저장 공간의 화재는 그 특성상 발화시점의 파악 및 초기진압이 어려우며, 초동 대처에 실패할 경우 표면화재에서 심부화재로 이어져 2차 화재피해가 발생할 가능성이 높다. 또한 심부화재는 다량의 독성가스발생과 재발화로 인해 인적 물적 피해를 야기할 수 있으므로 다공성 가연물을 취급하는 저장공간을 중심으로 피해경감 대책이 요구된다. 본 연구는 침윤소화약제 사용 시 다공성 물질의 심부화재 소화 효율 증대에 관한 기초 연구로써, 계면활성제의 농도에 따른 침투성능의 향상에 관한 연구를 수행하였다. 실험에 사용된 다공성 물질은 국내 사용 목재의 75%를 점유하고 있는 뉴질랜드산 소나무의 원목 목분을 사용하였다. 소화용수는 침윤소화약제에 사용되고 있는 Butyl Di Glycol (BDG)을 선택하여 농도에 따른 표면장력별 표준시료를 제작하여 실험을 수행하였다. 실험은 NFPA 18의 Deep-Seated Fire Test를 기초로 수행하였으며, 살수량과 다공성 물질 내부로의 침투량, 다공성 물질 외부로의 배출량 측정 실험을 실시하였다. 실험결과 계면활성제 농도에 따른 표면장력이 감소함에 따라 거시적 침투속도는 감소하나 다공성 물질 내부로의 침투량은 증대되는 특성을 확인하였다.

Legal Aspects on ICAO SARPs Regarding Alternative Fire Extinguishing Agent to Halon Fire Extinguishers

  • Lee, Gun-young;Kang, Woo-Jung
    • 항공우주정책ㆍ법학회지
    • /
    • 제33권1호
    • /
    • pp.205-226
    • /
    • 2018
  • 항공운송의 지속 가능한 발전을 위하여 환경보호 분야와 관련된 국제표준의 수립과 적용은 매우 중요하다. 항공기 엔진과 보조동력장치 및 화물실의 화재를 진입하기 위하여 할론을 대체하는 소화물질의 개발과 사용은 오존층 보호를 위하여 요구되어 왔다. 국제민간항공기구는 관련 국제표준의 준비에 적극적이었지만 화재를 진압할 수 있는 대체물질의 인증은 기술적 준비 관계로 지연되어 왔다. 따라서 관련된 국제표준 및 권고의 이행 시기는 당초 2016년 말에서 2년 후인 2018년 말로 연장 되었다. 이러한 지연은 국제민간항공기구 회원국들의 국제표준 및 권고의 이행에 있어 혼선을 가져왔으며 이러한 이슈에 대한 추가적인 관심과 토론이 필요하게 되었다. 국제민간항공기구 이사회 및 항행위원회는 기술력의 진전 상황을 확인하여 이행 시기를 조기에 선정할지 또는 충분한 기술이 개발된 이후로 할지를 결정할 필요가 있다. 또한 회원국들이 할론을 불필요하게 대기중에 방출하지 않도록 하기 위하여 항공기용 소화기를 재충전 할 때는 소화기 제작사로 보내어 전문적인 방범으로 배출을 최소화 하는 방법을 고려할 필요가 있다. 국제민간항공기구의 국제표준과 권고의 성공적인 이행을 위한 이행과제 항목이 개발 되었는데, 차이점의 통보, 국가 이행계획의 수립, 자국 규정의 개정 또는 이행안 초안 마련, 법령 및 이행방안의 채택 등이 그것들이다. 회원국들은 이러한 이행과제 항목을 참고하여 자국의 법안마련 절차를 수립하는데 참고 할 수 있다. 본 내용은 2017년 몽골 울란바타르에서 개최된 제54차 아태지역 항공국장회의에서 제출되고 발표되어 논의된 바 있으며 여러 회원국들의 관심이 있었다. 국제민간항공기구 이사회 및 항행위원회는 국제표준 및 권고의 이행과 관련 회원국들의 어려움과 혼선을 배제하고 유효일자 이내에 적절하게 이행되게하기 위하여 국제표준 및 권고의 마련 과정에 법률국 소속 법률가들과 반드시 협의할 필요가 있다.