• 제목/요약/키워드: Fire Behavior

검색결과 591건 처리시간 0.036초

건축물 화재안전설계를 위한 주요가연물조사 및 화재성장율 예측에 관한 연구 (A Forecast Study on the Fire Growth Rate and Investigation of Combustible for Fire Safety Design in Building)

  • 서동구;김동은;김봉찬;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.133-135
    • /
    • 2012
  • The Fire growth rate(kW/s2) is significant impact on initial fire behavior in fire safety design of buildings. As a result of domestic existing combustibles, this study analyzed considering matters in techniques for calculating caloric values, and then made an investigation sheet. By utilizing written combustion sheets, the study could suggest a standard model at common houses and dense ones after getting caloric value information in dense ones. As a result, fire growth rate is experiment 1(0.01), experiment 2(0.0048), FDS(0.0072), MATSUYAMA equation(0.0144).

  • PDF

무선 센서 네트워크 기반의 화재 대피 유도 연구 (A Study of Fire Shunt Guidance Based on Wireless Sensor Networks)

  • 김용우;김도현;곽호영;박희동
    • 한국멀티미디어학회논문지
    • /
    • 제11권11호
    • /
    • pp.1547-1554
    • /
    • 2008
  • 본 논문은 센서 네트워크를 이용하여 실시간으로 건물 내부의 화재 정보를 감시하고, 화재 발생 시 적절한 대피 경로를 제안하는 화재 대피 유도 시스템 모델을 제안한다. 이 시스템 모델은 센서 경보 모듈(sensor alert module), 행위 제안 모듈(behavior suggestion module), 비상 장치 제어 모듈(emergency device control module) 등으로 구성된다. 센서 경보 모듈은 센서 네트워크에서 수집한 정보를 주기적으로 감시하고, 규칙기반 알고리즘을 이용하여 화재 여부를 판별한다. 그리고 행위 제안 모듈은 센서 경보 모듈이 생성한 위험 센서 목록(danger sensor list)을 가지고 화재지역을 파악하여 화재 위치에 따른 비상등의 방향을 제시하고, 비상 장치 제어 모듈은 제시된 비상등의 방향에 따라 관련 비상 장치를 제어하거나 화재 상태를 도시한다. 이 시스템의 동작을 검증하기 위해 가상으로 무선 센서 네트워크의 데이터를 생성하여 인터넷 웹 기반의 화재 대피 유도 시스템을 구현하여 실험한다. 향후 본 연구를 통하여 대형 건축물에서 화재 발생과 같은 긴급 상황 발생할 경우 사람들을 안전하게 보호할 수 있을 것으로 사료된다.

  • PDF

Enhancing fire resistance of steel bridges through composite action

  • Kodur, Venkatesh K.R.;Gil, Augusto
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.353-362
    • /
    • 2022
  • Bridge fire hazard has become a growing concern over the last decade due to the rapid increase of ground transportation of hazardous materials and resulting fire incidents. The lack of fire safety provisions in steel bridges can be a significant issue owing steel thermal properties that lead to fast degradation of steel properties at elevated temperatures. Alternatively, the development of composite action between steel girders and concrete decks can increase the fire resistance of steel bridges and meet fire safety requirements in some applications. This paper reviews the fire problem in steel bridges and the fire behavior of composite steel-concrete bridge girders. A numerical model is developed to trace the fire response of a typical bridge girder and is validated using measurements from fire tests. The selected bridge girder is composed by a hot rolled steel section strengthened with bearing stiffeners at midspan and supports. A concrete slab sitting on the top of the girder is connected to the slab through shear studs to provide full composite action. The validated numerical model was used to investigate the fire resistance of real scale bridge girders and the effect of the composite action under different scenarios (standard and hydrocarbon fires). Results showed that composite action can significantly increase the fire resistance of steel bridge girders. Besides, fire severity played an important role in the fire behavior of composite girders and both factors should be taken into consideration in the design of steel bridges for fire safety.

화점높이 변화에 따른 메탄올의 소규모 Pool 및 Whirl Fire의 연소특성 (Combustion Characteristics of Pool and Whirl Fire on Methanol by Height of Fire Source using the Small Scale)

  • 박형주
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.73-78
    • /
    • 2012
  • 화점높이 변화에 따른 풀 화재와 회오리 화염의 연소특성을 알아보기 위하여 인화성 액체인 메탄올을 $100{\times}100{\times}50$ 크기의 스테인레스 재질의 사각형 용기에 넣고 연소실험을 하였다. 연소시간, 질량감소속도, 화염온도, 화염높이 및 외부로부터 화염으로의 공기유입속도 등을 측정하였으며, 연소시 화염의 거동은 비디오카메라를 이용하였다. 모든 실험결과로부터 화점높이 변화에 따른 연소특성은 풀 화재보다는 회오리 화염에 있어서 더 큰 영향을 준다는 것을 알 수 있었다.

화재시 연기거동에 관한 실험 및 해석적 연구 (An Experimental and Analytical Studies on the Smoke Movement by Fire)

  • 신이철;김수영;이주희;권영진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.15-18
    • /
    • 2008
  • A study on the fire and smoke behavior on experiments and analysis through STAR-CD in using about behavior analysis of the smoke. Kerosene of 3L in using on the experimental garden of 30cm in diameter same applies to heat release rate(HRR), buoyant force by Plume can be calculated at a rate of 1m/s. The result of experiment in average of velocity were 0.29m/s, and interpreted result were 0.28m/s. Besides, it is proved by interpreted that behavior of smoke movement can be not observed in the experiment. After smoke is Plume increased, ceiling-jet in formation being descend in smoke layer will be more thick smoke layer, and then vertical wall is collapsed in formation of wall-jet being descend. It is defined that smoke layer is more thick through descending course in wall-jet and ceiling-jet.

  • PDF

Transient heat transfer analysis using Galerkin finite element method for reinforced concrete slab exposed to high elevated temperature

  • Han, Byung-Chan;Kwon, Young-Jin;Lee, Byung-Jae;Kwon, Seung-Jun;Chae, Young-Suk
    • Computers and Concrete
    • /
    • 제18권6호
    • /
    • pp.1097-1112
    • /
    • 2016
  • Fire loading causes a critical collapse of RC (Reinforced Concrete) Structures since the embedded steels inside are relative week against high elevated temperature. Several numerical frameworks for fire resistance have been proposed, however they have limitations such as unstable convergence and long calculation period. In the work, 2-D nonlinear FE technique is proposed using Galerkin method for RC structures under fire loading. Closed-form element stiffness with a triangular element is adopted and verified with fire test on three RC slabs with different fire loading conditions. Several simulations are also performed considering fire loading conditions, water contents, and cover depth. The proposed numerical technique can handle time-dependent fire loading, convection, radiation, and material properties. The proposed technique can be improved through early-aged concrete behavior like moisture transport which varies with external temperature.

화재 피해를 입은 일반강도 RC 보의 보수성능 (Structural Behavior of Retrofitted RC beams with Fire Damages)

  • 안주희;신영수;이차돈;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1013-1016
    • /
    • 2003
  • This paper is to evaluate practically the techniques and materials of repair for RC elements with fire damages as well as to investigate the structural behavior of RC beams according to pre- or post-repair after fire-damages. For this purpose, normal concrete flexural specimens were exposed to high temperatures by the ISO 834 specification. After natural cooling and post-fire-curing in a natural environment for 2 months, the specimens were repaired with polymer cement mortar for 1 month curing.

  • PDF

대형서점 적재가연물의 초기 연소발열성상 (Heat Release Characteristics of Typical Live Fire Load in Large Bookstore)

  • 남동군
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.88-94
    • /
    • 2011
  • 건축물 적재가연물의 연소성상 및 발열특성은 건물 내부의 화재전파속도와 화재규모 등을 크게 좌우하는 중요한 요인이다. 그러나 대형 서점의 적재가연물은 다른 건축용도에 비해 다량 적재되어 있기 때문에 화재시 건물 전체의 화재피해가 대형화할 가능성이 있지만 연소발열성상이 화재실험 등으로 파악되어 있지 않다. 따라서 본 연구는 대형서점의 적재가연물인 목재 서가 등을 재현한 시험체를 대상으로 연소실험을 실행하여 연소발열성상을 파악하였다. 또한 이 결과를 바탕으로 대형서점의 화재시 화재안전성을 검토하고 대형 서점의 화재안전설계에 필요한 적재가연물의 연소표면적당 최대열방출률과 화재성장률 등을 제시하였다.

소방공무원의 건강증진행위 영향요인 (Influencing Factors on Health Promotion Behavior of Fire Officers)

  • 김자옥;김자숙;박아영;한수정
    • 한국직업건강간호학회지
    • /
    • 제22권3호
    • /
    • pp.218-227
    • /
    • 2013
  • Purpose: The purpose of this study was to investigate the factors influencing health promotion behavior of fire officers in Korea. Methods: It was a descriptive study. The subjects were comprised of 104 fire officers by self-reported questionnaires from January to February 2012. The instruments used for this study were a health belief, self-efficacy and health promotion lifestyle profile II. The data were analyzed using SPSS/WIN 14.0. Results: The scores of health promotion behavior of fire officers were 2.76 (on a 4-point scale) and of health belief were 2.98 (on a 4-point scale), followed by perceived benefits at 3.45, perceived seriousness at 3.02, perceived sensitiveness at 2.82, perceived barriers at 2.23, and self-efficacy at 3.04 (on a 4-point scale). The health promotion behavior was very closely correlated with the health belief (r=0.49, p<.001). In the sub region, perceived benefit was correlated (r=0.28 p=.005) and the perceived seriousness (r=0.38, p<.001), the perceived sensitiveness (r=0.36, p<.001), and self-efficacy (r=0.55, p<.001) were correlated. Two significant variables influencing health promotion behavior of fire officer were self-efficacy and perceived seriousness (explained 41.0%). Conclusion: It suggested that self-efficacy and perceived seriousness should be considered when developing a fire officers's health promoting program.