• 제목/요약/키워드: Fire Alarm System

검색결과 163건 처리시간 0.031초

IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석 (Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권2호
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

디지털 방식 무선 화재알림설비의 신호 패턴 인식기법 적용 (Application of Signal Pattern Recognition Technique of Digital Wireless Fire Alarm System)

  • 박승환;김두현;김성철
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.14-21
    • /
    • 2022
  • The purpose of this study was to apply the signal pattern recognition technique to the digital wireless fire-alarm system and to reduce unwanted fire alarms. In this study, the fire alarms of the K Institute, which operates the largest digital wireless fire-alarm system in Korea, were classified into normal operations and unwanted fire alarms, and these were analyzed and compared with actual fire signals. In addition, by designing a non-fire signal filter and applying it to the K Institute, we confirmed that the monthly unwanted fire alarm rate of all 5,713 detectors decreased sharply. In particular, the unwanted fire alarm rate for flame decreased from 1.09% to 0.11% and the unwanted fire alarm rate for smoke decreased from 0.65% to 0.035%.

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선 (Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver)

  • 지승욱;김시국;양승현;이재진;김필영;이춘하
    • 조명전기설비학회논문지
    • /
    • 제25권5호
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

자동화재탐지설비의 신뢰성 개선에 관한 연구 (Research on the Reliability Improvement of Automatic Fire Alarm System)

  • 손영진;이영일;이상현
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.42-49
    • /
    • 2008
  • 본 연구에서는 기존의 자동화재탐지설비의 오동작(비화재보, 실보)과 빈번한 오동작으로 인한 전원의 차단 등의 문제점을 해결하고 보다 높은 신뢰성을 갖는 자동화재탐지설비를 구성하기 위한 방안을 제시한다. 제안된 방식은 다중센서를 이용한 마이크로프로세서-기반의 디지털 제어시스템으로서 화재 시 발생되는 여러 가지 연소생성물을 감지하기 위해서 열, 연기, CO 센서 등을 복합적으로 사용한다. 이와 같은 방식에 따라 자동화재탐지설비의 오동작 발생 가능성을 줄인 화재감지시스템을 구성하였고, 다중센서 화재감지장치의 화재 감지 및 판별 알고리즘에 의해서 화재발생의 여부를 디지털 제어시스템에 의해서 신뢰도 높게 판단함을 실제 시험을 통해 검증하였다. 실제 화재감지시스템을 구성하였고, 화재시험을 통해서 제안 된 방식의 향상된 신뢰도를 검증하였다.

자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구 (The study of Connection Emergency lantern with Fire Alarm System)

  • 전중함;이상화;권오수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

공동주택 화재경보 발생음 특성에 관한 실험연구 (Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings)

  • 이민주;강희혁;권봉석;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구 (A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment)

  • 이태규;최경서;신연순
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권7호
    • /
    • pp.217-224
    • /
    • 2022
  • 오늘날 기술과 산업의 발전으로 특수건물이 늘어남에 따라 특수건물 내 화재 사고가 증가하고 있다. 그러나 정보통신기술의 빠른 발전에도 불구하고 낙후되고 실효성을 갖추지 못한 실내 화재 경보 시스템을 사용함으로 인해 인명 피해가 꾸준히 발생하고 있다. 본 연구에서는 음향경보를 이용하는 기존 실내 화재 경보 시스템이 건물 내 인원들에게 충분한 경보를 전달하지 못하는 '경보의 사각지대 문제'를 개선하고자 에지 컴퓨팅과 비콘을 활용한 화재 경보 시스템을 설계하고 구현하였다. 제안하는 개선된 화재 경보 시스템은 말단 센서 노드와 에지 노드, 사용자 애플리케이션, 서버로 구성된다. 말단 센서 노드는 실내 환경 데이터를 수집하여 에지 노드로 전송하고, 에지 노드는 전송받은 정보를 기반으로 화재 발생 여부를 모니터링 한다. 또한 에지 노드는 비콘 신호를 지속적으로 발생시켜 신호 범위 내의 사용자 애플리케이션이 설치된 스마트기기의 정보를 수집하여 서버 데이터베이스에 저장하고, 화재 발생 시 수집한 기기들의 정보를 바탕으로 모든 재실 인원에게 애플리케이션 푸시 형태로 화재 경보를 전송한다. 구현한 화재 경보 시스템의 적용 가능성을 검증하기 위해 강의실이 밀집한 대학교의 한 건물에서 신호 유효 범위 측정 실험을 진행한 결과, 에지 노드의 비콘 신호 범위 내에서 정상적으로 기기 정보를 수집하고, 수집한 정보를 바탕으로 특정 사용자들에게 신속하게 화재 경보를 전송함을 확인하였다. 이를 통해 수시로 변하는 출입자들의 정보를 유동적으로 수집하고, 이를 바탕으로 사용자와 매우 인접한 스마트기기로 경보를 전송함으로써 '경보의 사각지대 문제'를 해결하는데 적용할 수 있음을 확인하였다. 또한 실험 결과 분석을 통해 제안하는 화재 경보 시스템을 실내 공간의 특징에 따라 효과적으로 적용하는 방안을 제시하였다.

아날로그 주소형 감지기와 자동화재탐지 시스템의 설계 및 구현사례에 대한 고찰 (A Study on Design and Implementation of an Analog Addressable Detector and a Fire Alarm System)

  • 김종태;홍세권;유영신;정해성
    • 한국화재소방학회논문지
    • /
    • 제24권4호
    • /
    • pp.1-11
    • /
    • 2010
  • 본 논문은 최근의 정보통신기술을 적용하여 아날로그 감지기와 화재경보시스템의 설계와 구현방법에 대한 사례를 기술하였다. 근거리와 원거리뿐만 아니라 중대형 규모의 건물에 설치할 수 있도록 감지기에서 부터 시스템까지 계층구조로 설계하였고, 대량의 이벤트를 효율적으로 처리하여 많은 정보를 보여주도록 통신프로토콜부터 응용프로그램까지 일관되게 설계하였다. PC 기반의 화재경보시스템은 Microprocessor 기반의 해외 제품보다 고속으로 대용량을 처리하고 큰 화면에 많은 정보를 제공한다. 그러므로 수천 개의 아날로그 감지기를 설치하는 대형건물도 하나의 시스템에 쉽게 수용할 수 있고 다중화장치를 이용하여 설치비용도 크게 절약할 수 있다. 본 시스템에서 구현된 경보시나리오는 경보가 발생할 때 비화재와 실화재를 구분하는데 큰 역할을 할 것으로 판단된다.

화재감지기의 오보 감소를 위한 구조 신뢰도 분석 (Structural Reliability Analysis of Automatic Fire Detectors for Reduction of False Alarms)

  • 김주홍;임현교
    • 한국안전학회지
    • /
    • 제8권1호
    • /
    • pp.6-12
    • /
    • 1993
  • Now it is reported that there are many companies and factories which confront to the problem of false alarm in Automatic Fire Detecting System (AFDS). Though an AFDS is a high-priced and very important device in detecting a fire. the problem degrades the reliability and utility, eventually faith. of the system. This is a research concerned about the problem of false alarm of fire detectors in an AFDS. Structure of detectors was modeled up as a general K out-of n system. and reliability characteristics including false alarm rate and missed alarm rate, are derived from it. For decision of an optimal structure of detectors. preliminary analysis on various criteria is accomplished. It is concluded that appropriate modification of a detector with plural sensors may increase the system reliability and decrease the false alarm rate.

  • PDF