• 제목/요약/키워드: Fire Alarm Device

검색결과 35건 처리시간 0.019초

공동주택에서의 화재 경보음 전달특성에 관한 연구 (An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings)

  • 이민주;김명준;윤명오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

공동주택 화재 경보음 전달특성과 개선방안 고찰 (An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings)

  • 이민주;윤명오;김명준
    • 한국소음진동공학회논문집
    • /
    • 제16권6호
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

무선 감응식 주택 단독 화재 경보 시스템 개발 (Development of a Single Fire Alarm System of House Based on Wireless Communication)

  • 박현호;조성진;박병화;허정훈;고윤석
    • 한국전자통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.1017-1022
    • /
    • 2018
  • 본 논문에서는 주택 내의 단독 화재경보기들이 무선통신을 통해 상호 화재 정보를 공유함으로서 심야 시간대의 화재 인지력 저하 문제, 방 간 격벽으로 인한 경보 신호 감쇄 문제를 해소할 수 있는 무선 감응식 주택 단독 화재경보기를 개발하였다. 무선 감응식 화재경보기는 온도 센서와 가스 센서를 기반으로 온도와 $CO_2$ 농도를 감시, 주택의 화재를 감지하고 무선 송수신 모듈 등을 이용하여 다른 방의 단독 무선 경보기들에게 화재 경보를 전송함으로서 신속하고 정확한 화재인지가 가능하도록 설계되었다. 아두이노를 주제어장치로 하는 3개의 무선 감응식 단독화재 경보기의 시작품들이 제작되었으며, 온도 및 가스 시험에서 정확하게 동작함으로서 그 유용성을 확인하였다.

에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구 (A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment)

  • 이태규;최경서;신연순
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권7호
    • /
    • pp.217-224
    • /
    • 2022
  • 오늘날 기술과 산업의 발전으로 특수건물이 늘어남에 따라 특수건물 내 화재 사고가 증가하고 있다. 그러나 정보통신기술의 빠른 발전에도 불구하고 낙후되고 실효성을 갖추지 못한 실내 화재 경보 시스템을 사용함으로 인해 인명 피해가 꾸준히 발생하고 있다. 본 연구에서는 음향경보를 이용하는 기존 실내 화재 경보 시스템이 건물 내 인원들에게 충분한 경보를 전달하지 못하는 '경보의 사각지대 문제'를 개선하고자 에지 컴퓨팅과 비콘을 활용한 화재 경보 시스템을 설계하고 구현하였다. 제안하는 개선된 화재 경보 시스템은 말단 센서 노드와 에지 노드, 사용자 애플리케이션, 서버로 구성된다. 말단 센서 노드는 실내 환경 데이터를 수집하여 에지 노드로 전송하고, 에지 노드는 전송받은 정보를 기반으로 화재 발생 여부를 모니터링 한다. 또한 에지 노드는 비콘 신호를 지속적으로 발생시켜 신호 범위 내의 사용자 애플리케이션이 설치된 스마트기기의 정보를 수집하여 서버 데이터베이스에 저장하고, 화재 발생 시 수집한 기기들의 정보를 바탕으로 모든 재실 인원에게 애플리케이션 푸시 형태로 화재 경보를 전송한다. 구현한 화재 경보 시스템의 적용 가능성을 검증하기 위해 강의실이 밀집한 대학교의 한 건물에서 신호 유효 범위 측정 실험을 진행한 결과, 에지 노드의 비콘 신호 범위 내에서 정상적으로 기기 정보를 수집하고, 수집한 정보를 바탕으로 특정 사용자들에게 신속하게 화재 경보를 전송함을 확인하였다. 이를 통해 수시로 변하는 출입자들의 정보를 유동적으로 수집하고, 이를 바탕으로 사용자와 매우 인접한 스마트기기로 경보를 전송함으로써 '경보의 사각지대 문제'를 해결하는데 적용할 수 있음을 확인하였다. 또한 실험 결과 분석을 통해 제안하는 화재 경보 시스템을 실내 공간의 특징에 따라 효과적으로 적용하는 방안을 제시하였다.

공동주택 화재경보 발생음 특성에 관한 실험연구 (Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings)

  • 이민주;강희혁;권봉석;김명준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

화재감지기의 오보 감소를 위한 구조 신뢰도 분석 (Structural Reliability Analysis of Automatic Fire Detectors for Reduction of False Alarms)

  • 김주홍;임현교
    • 한국안전학회지
    • /
    • 제8권1호
    • /
    • pp.6-12
    • /
    • 1993
  • Now it is reported that there are many companies and factories which confront to the problem of false alarm in Automatic Fire Detecting System (AFDS). Though an AFDS is a high-priced and very important device in detecting a fire. the problem degrades the reliability and utility, eventually faith. of the system. This is a research concerned about the problem of false alarm of fire detectors in an AFDS. Structure of detectors was modeled up as a general K out-of n system. and reliability characteristics including false alarm rate and missed alarm rate, are derived from it. For decision of an optimal structure of detectors. preliminary analysis on various criteria is accomplished. It is concluded that appropriate modification of a detector with plural sensors may increase the system reliability and decrease the false alarm rate.

  • PDF

CCD 카메라를 이용한 열화상 실시간 추정과 화재경보 (Thermal Image Real-time estimation and Fire Alarm by using a CCD Camera)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제30권6호
    • /
    • pp.92-98
    • /
    • 2016
  • 본 논문은 Charge-Coupled Device (CCD) 카메라를 이용한 열화상의 실시간 추정과 화재경보에 대하여 논한 것으로 각도 및 위치에 따른 특징점 분석과 동일 형상의 벡터 성분 좌표점 설정에 따른 이미지 융합이 잘 되었다. 영상을 Display하는 픽셀의 데이터 값은 0~255, 센서 출력값은 0~5,000로 하여 정확성이 높았다. 시험결과 시험체로부터 500 m, 1000 m, 1500 m 거리에서 화염에 의한 시험체의 작동시간은 각각 7초, 26초, 62초 소요 되었고 화면이미지 생성이 효과적으로 이루어졌다. 화재 발생 진단은 주의/경보/화재의 3단계로 프로그램하여 Alarm의 순차적 동작과 SNS 전송이 이루어졌다. 비화재보시험을 위해 백열등, 형광등에 대해 시험하였으나 모두 비화재보를 발생하지 않았다. 시간대별 화염의 변화영상과 진행방향 및 확산속도의 분석은 화재진행상황 예측이나 열화상 실시간 추정과 경보로 비화재보 감소가 가능함을 확인하였다.

화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구 (Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function)

  • 고완수;최충석
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.43-48
    • /
    • 2020
  • 본 연구에서는 누전경보 기능이 내장된 누전경보차단기(JER-E2S, ETECKOREA Co., Korea)를 개발하고, 그 특성을 분석하였다. 개발된 누전경보차단기는 단상 220 V 전용으로 정격전류는 32 A, 20 A, 20 A(화장실용), 16 A 등이다. JER-E2S는 기존 누전차단기(ELB)의 특성을 모두 만족하고 있으며, 13 ± 2 mA의 저항성누설전류(Igr)인 화재전류가 전선로에 흐르면 실시간 검출하여 LED 램프로 위험 상태를 점멸할 수 있는 제품이다. 개발된 누전경보차단기는 LED 램프 및 통신기기 등에서 필연적으로 발생되는 용량성누설전류(Igc)에 대한 내성이 있어서 안정적인 전기 공급이 가능하다. 또한, 누전경보차단기는 순간지락 정전보호 기능이 있어서 작은 물방울 및 나뭇잎 등의 순간지락에 따른 차단기의 오동작 없이 전원 공급이 가능하다. 그리고 개발된 누전경보차단기의 대기전력은 0.1 W 이하로 기존 ELB에 비해 절전 성능이 3~8배 우수한 특성을 나타냈으며, 일반 120 ㎡의 아파트 1 세대에 10개 정도의 누전경보차단기가 설치되었을 때 1 개월에 2~5 kWh의 전기를 절감할 수 있다. 개발된 누전경보차단기는 기존 누전차단기의 특성을 만족할 뿐만 아니라 전기화재 예방기능 및 오동작 방지기능이 있어서 전원 품질이 우수하고, 전기화재 예방에 혁신적으로 기여할 수 있는 제품이다.

역사내 기존 시스템 인터페이스 방안 (A Plan of Existing System Interface within Station)

  • 이원재;안태기;신정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

UV 화재감지장치 개발 (The development of UV falme detector)

  • 권오승;정창기;이복영
    • 방재기술
    • /
    • 통권28호
    • /
    • pp.48-54
    • /
    • 2000
  • The technique detects radiant energy form a flaming fire of fuels contained carbonaceous material can be applied to fast growing fires. This technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not applied. In Korea Fire regulation, a flame detector should be install in case that the installation height is higher than 20[m], chemical plant, hangar refinery. Therefore it is really necessary that a flame detector has to be developed as soon as possible. With foundation technique of flame detector, ideal sensing element and stable circuit design, a trial UV flame detector is manufactured. The stable and reliable technique of flame detector is established through the repeateed perfomance test and modification. An early detecting fire alarm device is developed through the modification, supplement of the structure and circuit. Results of the R & D for the manufacture of an excellent flame detecting device is carried out with the establishment of technique for the mass production and the qualified manufacturing process.

  • PDF