• Title/Summary/Keyword: Fire Administration

Search Result 388, Processing Time 0.021 seconds

A Cooperating Plan of Fire Investigation: Focused on Public-Private Partnership Theory (화재조사의 협력방안 모색: 민관파트너십이론을 중심으로)

  • Lee, Ranny;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • This study is to search cooperation plan about fire investigation based on the public-private partnership. Especially focused on the partnership with 4 sector; the academic world, insurance sector, industrial world, professionalist of private fire investigation. In conclusion, Firstly a partnership with the academic world should have courses or school subject extensions related to fire investigation. Secondly, a partnership with insurance sector should secure trust through unifying estimate standard about the origin of damage. Thirdly, A partnership with industrial company is presented making collaboration team to investigate the fire investigation. Lastly, the partnership with the private professionalist related to fire investigation should strengthen credibility and expertise.

Combustion Characteristics of Pool and Whirl Fire on Methanol by Height of Fire Source using the Small Scale (화점높이 변화에 따른 메탄올의 소규모 Pool 및 Whirl Fire의 연소특성)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.73-78
    • /
    • 2012
  • This study is intended to understand flame behavior of pool and whirl fire by height of fire source. Liquid fuel was methanol which is used in many studies for pool and whirl fire. Size of vessel was $100{\times}100{\times}50$ and the vessel was made by stainless steel. Combustion time, mass loss rate, flame temperature, flame height and air entrainment rate from the outside to flame were measured, and flame behavior was visualized with video camera. Based on the experiment, it was found that combustion characteristics by height of fire source got a more effect on whirl fire than pool fire.

Optical Properties for Smoke Particles of Fire Sources According to UL 268 (UL 268 화원에 의한 연기입자의 광학적 특성)

  • Jee, Seung-Wook;Lee, Jong-Hwa
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.9-13
    • /
    • 2014
  • This paper is basic study for development of the photoelectric-type smoke detector that is able to distinguish fire source as well as fire detection. For this subject, Light source and sensor which is normally used for the conventional smoke detector are assembled for the optical chamber. Using 3 type of the test fires (the paper fire, the wood fire, the flammable liquid fire) this paper attempts to find optical properties of each fire. These 3 type of fire are used in the testing of smoke detector according to UL 268 standard. As the result, there are disambiguated between the paper fire and the wood fire in scattering and reason of extinction in the flammable liquid fire is different from that of the paper and the wood fire.

A study on the Improvements of the Fire Officials' Employment (소방공무원 공개채용 시험과목 조정에 관한 연구)

  • Woo, Seong-Cheon
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.153-161
    • /
    • 2008
  • The duty of fire officials are very complicated and various that a subject replacement for the fire officials' public examination for service is being required. The purpose of this study is to investigate the actual conditions of the fire officials' public employment system and find out current problems of it, to reconsider the speciality of the examination based on them, and to suggest a subject replacement for the examination to evaluate the duty accomplishment ability. This study presents not only assuring the speciality of fire officials but also the desirable plans to execute the Fire Relating Act effectively by replacing introduction of political science with fire service administration and adding the Fire Relation Law which is more connected on the local fire officials public written examination for service with duty.

Study on Improvement of Fire Investigation System (화재조사제도 개선방안에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.101-110
    • /
    • 2009
  • As the current fire investigation system in Korea has been performed mainly by the public sector such as fire service, police, etc., private fire investigation system such as 'private fire investigator system' to protect rights and interests of the sufferers from the fire accidents due to defective products showed very deficient. In addition, since the laws and regulations concerned about fire investigation are distributed into and applied for each organization, a lot of problems have been generated such as civil appeals due to duplicated investigations among similar organizations, excess reaction to exclude other organization from the fire investigation field, inefficient waste of administration force due to duplicated operation of fire investigation organization and manpower, etc. This study has surveyed generation operation conditions and problems of the fire investigation system in Korea and drawn its improvement method on the public and private sectors.

A STUDY on FOREST FIRE SPREADING ALGORITHM with CALCULATED WIND DISTRIBUTION

  • Song, J.H.;Kim, E.S.;Lim, H.J.;Kim, H.;Kim, H.S.;Lee, S.Y
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.305-310
    • /
    • 1997
  • There are many parameters in prediction of forest fire spread. The variables such as fuel moisture, fuel loading, wind velocity, wind direction, relative humidity, slope, and solar aspect have important effects on fire. Particularly, wind and slope factors are considered to be the most important parameters in propagation of forest fire. Generally, slope effect cause different wind distribution in mountain area. However, this effect is disregarded in complex geometry. In this paper, wind is estimated by applying computational fluid dynamics to the forest geometry. Wind velocity data is obtained by using CFD code with Newtonian model and slope is calculated with geometrical data. These data are applied fer 2-dimentional forest fire spreading algorithm with Korean ROS(Rate Of Spread). Finally, the comparison between the simulation and the real forest fire is made. The algorithm spread of forest fire will help fire fighter to get the basic data far fire suppression and the prediction to behavior of forest fire.

  • PDF

Assessment of Fire Risk Rating for Wood Species in Fire Event (화재 발생 시 목재 수종의 화재위험성 등급 평가)

  • Jin, Eui;Chung, Yeong-Jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.423-430
    • /
    • 2021
  • In order to evaluate the fire risk and fire risk rating of wood for construction materials, this study focused on fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) according to Chung's equations-III and -IV. Western red cedar, needle fir, ash, and maple were used as the specimens. The fire characteristics were investigated using a cone calorimeter (ISO 5660-1) equipment on the specimen. The FPI-III measured after the combustion reaction was 0.86 to 12.77 based on polymethylmethacrylate (PMMA). The FGI-III was found to be 0.63 to 5.26 based on PMMA. The fire rating according to the FRI-IV, which is the fire rating index, was 0.05 to 6.12, and the western red cedar was 122.4 times higher than that of the maple. The fire risk rating according to the FRI-IV increased in the order of maple, ash, needle fir, PMMA and western red cedar. The CO peak concentration of all specimens was measured as 103 to 162 ppm, and it was 2.1 to 3.2 times higher than 50 ppm, the permissible exposure limits of the US occupational safety and health administration. Materials such as western red cedar, which have a low bulk density and contain a large amount of volatile organic substances, have a low FPI-III and a high FGI-III, so they have a high fire risk rating.

A Study on the Tasks 119 Fire Service -The Two City of Fire & Disaster Management Department- (119 구급대원들의 업무에 관한 연구 -2개 광역시 소방구급대를 중심으로-)

  • Kim, Mi Sook;Yeo, Jin Dong
    • The Korean Journal of Health Service Management
    • /
    • v.1 no.1
    • /
    • pp.90-109
    • /
    • 2007
  • This Study aims to examine the relative importants of various tasks of EMT and to examine knowledge level and problems associated with AED. It is based on the survey of paramedics and rescurers. The instrument by Hoe Sum Lim(1999) was used. as the questionaire for this research. The collected data were analyzed by means of $x^2$ test, t-test, and measured by percents. The results for this study were follows: 1) Among the tasks of EMI, "Basic Life Support" were rated as the most important, followed by "O2 supply" and foreign-body removal from mouth. 2) Some of the lower level of importance in task were Intubation, IV, dextrose infusion of Hypoglycemia, NTG S/L for chest pain, hydration for fluid therapy, brochodilator IV for Bronchial Asthma. 3) Some of the lower level of importance in task were apply of MAST, Vital Sign check and administration of traction & spine immobilization & air splint. 4) The most important reason that the used of AED is delayed is "unclear boundary of treatment directed by medical control".

  • PDF