• Title/Summary/Keyword: Fire

Search Result 15,620, Processing Time 0.039 seconds

Introduction of Fire Research in China

  • Weicheng, Fan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.35-43
    • /
    • 1997
  • Fire research is urgently needed so as to mitigate fire damage with moderate costs. A system of fire research consisting of basic research, applied research and development of new technology for fire prevention and protection is being formed in China. A general structure of organizations related to fire research is outlined. Typical research work in the State Key Lab of Fire Science is given as an example of fire research in China including: Field-Zone-Network modeling of building fire, mechanism of boilover, forest fire behavior, computer modeling of fire spread in micsogravity, and duality of fire rules and its application.

  • PDF

Experimental Study on Fire Hazard of Residential Fires Before and After Sprinkler Activation

  • Sekizawa, Ai;Yanai, Eiji;Takemoto, Akio;Kozeki, Daisuke;Suzuki, Keiko
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.376-383
    • /
    • 1997
  • Fire experiments were conducted in a real scale room which is assumed to be a residential living room under the various opening conditions and locations of wood crib fire source to study on fire hazard before and after sprinkler activation. Concentrations of oxygen and carbon monoxide, smoke density, and temperature were measured to look into environmental conditions in a room of fire origin. The response time of residential sprinklers was also examined in relation to distance between sprinkler heads and a fire source.

  • PDF

A Study on Fire Resisting Construction Design in Advanced Nation (선진각국의 내화설계법에 관한 연구)

  • 김화중
    • Fire Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.17-30
    • /
    • 1988
  • In Our Country, the fire safety design is done by the standard furnace fire test. This is haphazard procedure, as the standard furnace fire endurance of structural elements has little relation to the structural element endurance in an actual Compartment fire. The standard furnace fire test results, though obtained at great cost, do not contribute to the understanding of the behavior of structural elements in an elevated temperature environment and can not be applied rationally in fire safety design. The response of a steel and reinforced concrete structure in fire is a very complex problem. Therefore, in this paper is explained about tendency of study for fire safety design in advanced nations.

  • PDF

Study on Sensitivities and Fire Area Errors in WRF-Fire Simulation to Different Resolution Data Set of Fuel and Terrain, and Surface Wind (WRF-Fire 산불 연료 · 지형자료 해상도와 지상바람의 연소면적 모의민감도 및 오차 분석연구)

  • Seong, Ji-Hye;Han, Sang-Ok;Jeong, Jong-Hyeok;Kim, Ki-Hoon
    • Atmosphere
    • /
    • v.23 no.4
    • /
    • pp.485-500
    • /
    • 2013
  • This study conducted WRF-Fire simulations in order to investigate sensitivities of the resolution of fire fuel and terrain data sets, and the surface wind to simulated fire area. The sensitivity simulations were consisted of 8 different WRF-Fire runs, each of which used different combination of data sets of fire fuel and terrain with different resolution. From the results it was turned out that the surface wind was most sensitive. The next was fire fuel and then fire terrain. Unfortunately, every run produced too much fire area. In other words no simulations succeeded in simulating such proper fire area so as for the WRF-Fire to be used realistically. It was verified that the errors of fire area from each runs were contributed by 41%, 53%, and 6% from surface wind, fire fuel, and fire terrain, respectively. Finally this study suggested that the selection of Anderson fuel category in the area of interest seemed to be very critical in the performance of WRF-Fire simulations.

A Study on Efficient Improvement Ways of Fire Protection Management System (방화관리제도의 효율적 개선방안에 관한 연구)

  • Kook, Hyeong-Ho;Jo, Dae-Ho;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.115-127
    • /
    • 2008
  • Fire protection management system has been introduced to prevent structure fire since establishment of Fire Prevention Act. Nevertheless, Damage by fires is continue. The main purpose of this study is to discuss approaches to improve fire protection management system into the fire prevention properties. Now fire protection management system has lots of the problems in managerial and systematical aspects. To improve these a unified fire protection management system must be establish by suggests revision of a unified Fire Prevention Act and foundation of Fire Prevention Institution, reform educational system for the fire safety directors would be essential to includes environment improvement, enhancement of certification requirements and education, a standardized computational management system of the fire protection properties must be build for efficient fire protection operations.

Experimental study on the reaction-to-fire performance of bed mattress in real scale (침대 매트리스 실물규모 화재안전성 실험 연구)

  • Park, Kye-Won;Jeong, Jae-Gun;Yang, Woo-Jin;Lee, Gil-Yong;Kim, In-Sun;Jeong, Jeong-Ho;Kim, Jeong-Wook
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.38-41
    • /
    • 2012
  • This study aims to analyze fourteen cases' HRR & SPR results on bed mattress's reaction-to-fire test in real scale where open flame burner system is used with total heat supply of 27 kW. Most cases show all burning within 5 minutes from the beginning of the test and 3 cases of them reach flashover situation.

  • PDF

A Study on Factors Affecting Fire Prevention (화재예방에 영향을 미치는 요인에 관한 연구)

  • Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.100-109
    • /
    • 2020
  • This study aims to empirically verify the factors affecting fire prevention, which is a dependent variable, by establishing a safety culture related to fire prevention, fire prevention education, fire prevention equipment, fire safety knowledge, and fire safety practices as independent variables. The results obtained from the multiple regression analysis were derived as follows in relation to fire prevention. The fire prevention education was found to have the most statistically significant effect on fire prevention, and the fire prevention facility was found to have a statistically significant effect on fire prevention. In addition, fire safety practice was found to have a statistically significant effect on fire prevention.

Detection of Fire Location And Reliability Improvement of the Conventional Fire Detector and P-type Receiver (재래식 화재감지기와 P형 수신기에 대한 화재위치검출 및 신뢰성 개선)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Yang, Seung-Hyun;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.5
    • /
    • pp.39-44
    • /
    • 2011
  • Automatic fire alarm system is set up to automatically detect fire on buildings. Because of economic reasons, P-type receiver and a conventional type fire detector is normally used for automatic fire alarm system in Korea. Because early detection of fire is regarded as important, the need of finding technique of fire location increases. This paper is studied a method to improve a reliability and add a function of fire location detection on a conventional type fire detector and P-type receiver. Fire location is detected by a method that controller attached on the receiver and the detector is read with a time lag. A reliability of fire detection alarm system is improved with a method that false fire alarm is able to decrease using two different principle detector together. This paper is studied for basic data of improvement of low-cost addressable automatic fire alarm system.

Calculation of Fire-resisting Time and Extraction of Simple Transplants in the Event of a Building Fire (건축물 화재시 필요내화 시간 산정 및 간이식 도출)

  • Kim, Yun-Seong;Han, Ji-Woo;kim, Hye-Won;Jin, Seung-Hyeon;Lee, Byeong-Heun;Kwon, Yeong-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.11a
    • /
    • pp.59-60
    • /
    • 2020
  • Large fires continue to spread throughout the building, including the fire in Uijeongbu in 2015, the fire in Jecheon in 2017, and the fire in Miryang in 2018. According to the above fire case investigation, major problems were the fire resistance performance of compartment members such as fire doors, the fire spread due to damage to exterior wall openings, and smoke spread through vertical openings. However, in South Korea, only specification design is implemented for buildings that are not subject to performance design. In addition, the analysis of the fire resistance performance standards of building members in the specification design showed that fire doors were not specified in detail for 60 minutes of insulation performance and 60 minutes of fire resistance performance of E/V doors, limiting the prevention of fire spread. Therefore, the purpose of this research is to prepare measures to prevent the spread of fire by presenting simple transplants for calculating the required fire time according to the architectural design conditions for the performance design of the components of the fire room according to the purpose of use of the front of the building.

  • PDF

Development of WSN(Wireless Sensor Network)-based Fire Monitoring Application System using Fire Detection Algorithm for Early Warning (조기 경보를 위한 화재 판단 알고리즘을 이용한 무선 센서네트워크 기반 화재 감시 응용 시스템 설계 및 구현)

  • Kim, Ah-Reum;Jo, Kyoung-Jin;Chang, Jae-Woo;Sim, Chun-Bo
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.504-514
    • /
    • 2009
  • Recently, fire monitoring application systems have been an active research area due to the safety of industries, historical monuments and so on. The fire monitoring application systems can reduce the damage of properties by providing earlier warning for possible fire situation. However, the existing systems have a drawback that they detect fire with delay due to their uniform epoch in fire detection algorithm. Moreover, they do not provide user-friendly graphical user interfaces in their fire monitoring systems. To resolve the problems, First, we propose a new fire detection algorithm (Early Fire Detection Fire Algorithm) which uses the distribution of sensing data for early fire detection. Our fire detection algorithm is better in terms of fire detection time than the existing work because it can set a start time of fire detection epoch dynamically based on data distribution. Second, we develop a fire monitoring application system which provides users with both a user-friendly graphical user interface and a fire alarm message when fire occurs. Finally, we show from our experiment that our developed system is effectively used for early fire warning in a variety of fire situations.