• Title/Summary/Keyword: Fir Use

Search Result 131, Processing Time 0.026 seconds

A Novel Method for Bitrate Control within Macroblocks Using Kalman and FIR Filters

  • Seok, Jin-Wuk;Yoon, Ki-Song;Kim, Bum-Ho;Lee, Jeong-Woo
    • ETRI Journal
    • /
    • v.33 no.4
    • /
    • pp.641-644
    • /
    • 2011
  • In this letter, we propose a novel bitrate control, using both Kalman and FIR filters, based on a Hamiltonian analysis with respect to the amount of bits from each macroblock, in an encoding of a general video codec such as H.264/AVC. Since the proposed bitrate control is based on the simple computation of an optimal control method based on the Hamiltonian analysis, it is not necessary to use additional computation, such as a DCT or quantization, to estimate the bits for bitrate control. As a result, the proposed algorithm can be applied to single-pass encoding and can provide sufficient encoding speed with respect to various applications, even those requiring real-time control.

A Study on the Design of Multiplierless FIR Filters (Multiplierless FIR여파기의 설계에 관한 연구)

  • Shin, Jae Ho;Lee, Chong Kak
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.2
    • /
    • pp.249-256
    • /
    • 1986
  • In this paper, we propose the MDM algorithm by which one can desing an FIR filter that is maximally flat and requires no multiplication. We use the modified MAXFLAT subroutive of Kaiser to achieve the maximally-flat characteristics. The filter coefficients are encoded in MDM-code and the optimal stepsize is determined the steepest- descent method. Simulation results shows that the FIR filter designed is almost maximally-flat in passband, but has about -30dB ripples in stopband due to MDM quantization error.

  • PDF

Improved Receding Horizon Fourier Analysis for Quasi-periodic Signals

  • Kwon, Bo-Kyu;Han, Soohee;Han, Sekyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.378-384
    • /
    • 2017
  • In this paper, an efficient short-time Fourier analysis method for the quasi-periodic signals is proposed via an optimal fixed-lag finite impulse response (FIR) smoother approach using a receding horizon scheme. In order to deal with time-varying Fourier coefficients (FCs) of quasi-periodic signals, a state space model including FCs as state variables is augmented with the variants of FCs. Through an optimal fixed-lag FIR smoother, FCs and their increments are estimated simultaneously and combined to produce final estimates. A lag size of the optimal fixed-lag FIR smoother is chosen to minimize the estimation error. Since the proposed estimation scheme carries out the correction process with the estimated variants of FCs, it is highly probable that the smaller estimation error is achieved compared with existing approaches not making use of such a process. It is shown through numerical simulation that the proposed scheme has better tracking ability for estimating time-varying FCs compared with existing ones.

Nutrient Use Strategy of Carpinus cordata Saplings Growing under Different Forest Stand Conditions (임분 조건이 다른 환경에서 하층식생으로 생육하는 까치박달(Carpinus cordata) 유목의 양분 이용 특성)

  • Kwon, Boram;Heo, Namjun;Shin, Hoyong;Kim, Hyun Seok;Park, Pil Sun;Yi, Myong Jong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.16 no.3
    • /
    • pp.188-196
    • /
    • 2014
  • This study aimed to understand the nutrient absorption, usage and allocation of Carpinus cordata in different soil and light environments. Seasonal changes of foliar nitrogen, phosphorous, chlorophyll contents, leaf mass per area (LMA) and nutrient retranslocation rates were investigated for C. cordata saplings growing in a natural deciduous broadleaved forest and an Manchurian fir (Abies holophylla) plantation in Gwangneung, Kyunggido. The deciduous forest had lower leaf area, higher light penetration, and better soil fertility than the Manchurian fir forest. However, available soil phosphorous content in the deciduous forest was only one third of that in the Manchurian fir forest, which caused lower foliar phosphorous content and higher P retranslocation rate of C. cordata in the deciduous forest than that in the Mancurian fir forest. Soil nitrogen contents in the deciduous forest were higher than that in the Manchurian fir forest, however, no differences in foliar nitrogen content and retranslocation rate in C. cordata between the two stands were found. C. cordata in the Manchurian fir forest with high LAI throughout a year, had lower LMA, foliar nitrogen content and chlorophyll a/b, while had higher total chlorophyll content and chlorophyll/N than that in the deciduous forest. These results implied C. cordata under different environments are using different strategies for nutrient use and allocations.

FIR CV-EWMA Control Chart (FIR CV-EWMA 관리도)

  • Hong, Eui-Pyo;Kang, Hae-Woon;Kang, Chang-Wook;Baek, Jae-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.3
    • /
    • pp.146-153
    • /
    • 2010
  • When the production run is short and process parameters change frequently, it is difficult to monitor the process using traditional control charts. In such a case, the coefficient of variation (CV) is very useful for monitoring the process variability. The CV control chart is an effective tool to control the mean and variability of process simultaneously. The CV control chart, however, is not sensitive at small shifts in the magnitude of CV. The CV-EWMA(exponentially weighted moving average) control chart which was developed recently is effective in detecting a small shifts of CV. Since the CV-EWMA control chart scheme can be viewed as a weighted average of all past and current CV values, it is very sensitive to small change of mean and variability of the process. In this paper, we propose an FIR(Fast initial response) CV-EWMA control chart to improve the sensitivity of a CV-EWMA scheme at process start-up or out-of-control process. Moreover, we suggest the values of design parameters and show the results of the performance study of FIR CV-EWMA control chart by the use of average run length(ARL). Also, we compared the performance of FIR CV-EWMA control chart with that of the CV-EWMA control chart and we found that the CV-EWMA control chart gives longer in-control ARL and much shorter out-of-control ARL.

Time-Domain Based Asynchronous IR-UWB Ranging System (시간 영역 기반의 비동기 IR-UWB 거리추정 시스템)

  • Kim, Hyeong-Rae;Yang, Hoon-Gee;Yang, Seong-Hyeon;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.347-354
    • /
    • 2011
  • This paper presents a time-domain based asynchronous IR-UWB ranging system. This system accomplishes the ranging by detecting peaks from the outputs of a correlator implemented by a FIR filter. To discriminate the peaks due to a signal component, we use windowing for the correlated data within which the data are sorted in amplitude-ascending order and the noise level is calculated. Comparing with the recently presented frequency-domain based ranging system, we show the system structure and explain how it operates for ranging. Moreover, through the simulations, the proposed system is compared with the frequency-domain based system in terms of performance.

Implementation of Self-Interference Signal Cancelation System in RF/Analog for In-Band Full Duplex (동일대역 전이중 통신을 위한 RF/아날로그 영역에서의 자기간섭 신호 제거 시스템 구현)

  • Lee, Jiho;Chang, Kapseok;Kim, Youngsik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.277-283
    • /
    • 2016
  • In this paper, a system of self-interference signal cancelation for in-band full duplex has been implemented and tested in RF/analog region. The system performance has been evaluated with NI5791 platform and NI Flex RIO. Due to the low power level of the NI5791, the RF signal is amplified by SKYWORKS SE2565T power amplifier. A circulator is used to feed the antenna both the transmitter and receiver. The RF FIR filter is designed by twelve delay taps in two different groups, and the interval between each delay tap is designed to have 100 ps. The amplified signal is distributed to antenna and the FIR filter by use of a 10 dB directional coupler. The tap coefficients of the RF FIR filter are tuned to estimate the self-interference signal coming from antenna reflection and the leakage of the circulator, and the self-interference signal is subtracted. The system is test with 802.11a/g 20 MHz OFMD at 2.56 GHz, and the output power of the amplifier of 0 dBm. The self-interference signal is canceled out by 53 dB.

Performance Analysis of Coding According to the Interpolation filter in Inter layer Intra Prediction of H.264/SVC (H.264/SVC의 계층간 화면내 예측에서 보간법에 따른 부호화 성능 분석)

  • Gil, Dae-Nam;Cheong, Cha-Keon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.225-227
    • /
    • 2009
  • International standard specification, H.264/SVC improved from H.264/AVC, is set up so as to promote free use of huge multimedia data in various channel environments.;H.264/AVC is a international standard speicification for video compression, adopted and commercialized as standard for DMB broadcasting by JVT of ISO/IEC MPEG and ITU-T VCEG. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding. Among prediction technologies, 'inter-layer intra prediction' is to use co-located block of up sampled sublevels as a prediction signal. At this time, application of interpolation is one of the most important factors to determine encoding efficiency. SVC's currently using poly-phase FIR filter of 4-tap and 2-tap respectively to luma components. This paper is written for the purpose of analyzing encoding performance according to the interpolation. For this purpose, we applied poly-phase FIR filter of '2-tap', '4-tap' and '6-tap' respectively to luma components and then measured bit-rate, PNSR and running time of interpolation filter. We're expecting that the analysis results of this paper will be utilized for effective application of interpolation filter. SVC standard uses 'intra/inter prediction' in AVC as well as 'inter-layer intra prediction', 'inter-layer motion prediction' and 'inter-layer residual prediction' to improve efficiency of encoding.

  • PDF

Photosynthetic Capacity and Water Use Efficiency under Different Temperature Regimes on Healthy and Declining Korean Fir in Mt. Halla (한라산 구상나무 건전개체와 쇠약개체의 온도변화에 따른 광합성능력과 수분이용효율)

  • Lim, Jong-Hwan;Woo, Su-Young;Kwon, Mi Jeong;Chun, Jung Hwa;Shin, Joon Hwan
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.705-710
    • /
    • 2006
  • We investigated seasonal photosynthetic capacity and water use efficiency changes of Korean fir (Abies koreana Wils.) trees located at three sites around the peak of Mt. Halla, Witseorum, Youngsil and Jindallebat. At each sites, we chose healthy and declining individuals to examine the differences of physiological characteristics between them. Net photosynthetic capacity in $15^{\circ}C$ were lower than those of $20^{\circ}C$ and $25^{\circ}C$. The difference of net photosynthetic capacity between healthy and damaged trees was clear in June and August but damaged trees recovered with passing of the time. There was no difference between healthy and damaged trees in September on photosynthetic rate. Generally, water use efficiency (WUE) of damaged trees was higher than healthy trees.

Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire (표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구)

  • Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.14-18
    • /
    • 2018
  • The earlier studies on the fire resistance performance of woods used as building materials have focused on confirming combustion characteristics of fire retardant or flame resistant treated wood. In this paper, to confirm internal temperature changes closely related to pyrolysis of woods exposed to the flame, heating experiments were conducted in a heating furnace according to the standard heating temperature curves after Douglas-fir, which is widely used as structural materials, was treated with a flame resistant solution and flame retardant paint. As a result of the experiment, it was confirmed that the thermal diffusion inside the wood has decreased when the wood was treated with the flame resistant solution. However, in high temperature, the flame resistant effect could not be expected due to the peeling of the coating in the case of the flame resistant paint treated wood. Therefore, it can be considered that it is more effective to use the flame resistant solution which penetrates in to the inside of the wood than flame resistant paint which forms the coating on the surface of the wood in order to enhance the flame resistance effect on the thick wood.