• 제목/요약/키워드: Finned tube

검색결과 159건 처리시간 0.025초

내관에 휜을 부착한 진공관형 집열기의 열성능 해석 (Thermal Performance Analysis of Glass Evacuated Solar Collector with a Finned Tube)

  • 김용;서태범;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제24권1호
    • /
    • pp.39-45
    • /
    • 2004
  • The thermal performance of glass evacuated tube solar collectors with finned tubes is numerically modelled with code and investigated to see the effect of toe inner tube diameter and incidence angle. The solar collector consists of a two-layered glass tube and an inner tube. Finned tubes are used as the inner tube of the collector in order to improve the performance of the solar collector. Two strip-type fins are attached on the opposite sides of the inner tube surface. The fin is wide enough to be tightly fatted inside the glass tube. The results show that if the incidence angle is small, the effect of the tube diameters is not significant on the thermal performance and the outlet air temperature. If the incidence angle is large, however, the outlet air temperature and the performance increases as the inner tube diameter increases.

레이놀즈 수가 낮은 영역에서 와류발생기를 적용한 핀-관 열교환기 성능평가 (Performance Evaluation of Finned Tube Heat Exchanger with Vortex Generators in a Low Reynolds Number Regime)

  • 곽경민;송길달
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.151-157
    • /
    • 2006
  • The present paper reports the method for evaluation of heat-transfer performance of finned tube heat exchangers in a low Reynolds number regime (Re = $160\~800$) and also reports the data of heat transfer and pressure loss taken from a finned tube heat exchanger with/without vortex generators (VGs) installed as a heat-transfer enhancement device. The evaluation is based on the modified single blow method conducted in a specially designed low Reynolds number duct. Three different test core geometries, i.e., fin only, fin-tube without VGs and that with VGs, are studied here. The data of heat transfer and pressure loss taken from the fin only geometry agree well with the empirical correlations, thus validating the present method as used for low Reynolds number regime. The data taken from the finned tube geometries with and without VGs are presented and compared to examine the effect of VGs in the low Reynolds number regime.

국산(國産) 저질무연탄(低質無煙炭) 연소용(燃燒用) 유동층(流動層) 연소로(燃燒爐) 개발(開發) 및 열효율(熱效率) 증대(增大)에 관한 연구(硏究) (A Study on the Augmentation of Thermal Efficiency and the Development for the Fulidized Bed Combustor Untilizing Korean Low Grade Anthracite Coals)

  • 이관석
    • 설비공학논문집
    • /
    • 제2권2호
    • /
    • pp.112-118
    • /
    • 1990
  • Characteristics of heat transfer in a smooth and finned tube located vertically in atmospheric fluidized bed combustor which uses low grade anthracite coals was studied. Experiments to investigate the characteristics of heat transfer between smooth and finned tube are carried out and the results depend on particle size, fluidizing air velocity and bed temperature are summarized. It is found that heat transfer coefficient of the smooth and finned tube increases with decrease in particle diameter and increase in bed temperature. Furthermore, it is noted that heat transfer coefficient increase at the first with increase in the velocity of fluidizing air and tends to decrease at a certain fluidizing air velocity. The increase of heat transfer coefficient for the finned tube is appeared to be increased in 30% compared to that for the smooth tube.

  • PDF

휜붙이 수직냉각관 주위의 상변화물질에서 응고열전달에 관한 연구 (A study on heat transfer during solidification of phase change material on a finned vertical cooling tube)

  • 정석주;송하진
    • 한국안전학회지
    • /
    • 제11권2호
    • /
    • pp.33-41
    • /
    • 1996
  • Experiments were performed to study solidification of phase change material on a finned vertical tube when either conduction In the solid or natural convection in a liquid controls the heat transfer. The liquid was housed in a cylindrical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the solidification occurred at a finned and unfinned vertical tube positioned along the axis of the vassel. The phase change material(PCM) employed in this experiment is 99 percent pure n-Octacosan paraffin($C -{28}H_{58}/$). For conduction-controlled and convection-controlled solidification, the enhancement of the solidified mass rate due to finning is great when the solidified layer is thin and decreases as the layer grows thicker. It is studied that the latent energy($E_{\lambda}$) is the largest contributor to the total extracted energy($E_{\lambda} + E_{sl}+E_{s2}$) and the total extracted energy rate at a finned vertical tube is greater than that at a unfinned vertical tube.

  • PDF

설계조건에 따른 핀-튜브 증발기의 열전달 특성 (Heat Transfer Characteristics on Design Conditions of Finned-Tube Evaporators)

  • 강희정;이윤수;권영철;장근선;김영재
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.46-54
    • /
    • 2002
  • To investigate the design effects of a heat exchanger on a tube type, a tube circuit and a fin pitch, an experimental study on the heat transfer characteristics of finned- tube evaporators was performed. The refrigerant was R-22. A refrigerant loop was established to measure the heat transfer rate, the air heat transfer coefficient. The experimental results showed that the heat transfer characteristics of the evaporators were affected by the design parameters. And the heat transfer rate of the slit fin was better about 25%, compared to those of the louver fin. In the present experimental range, the heat transfer performance with the straight tube circuit was more remarkable than that of the zigzag tube circuit, as seen from temperature variations of the evaporator exit. $\jmath$-factor on the tube type, the tube circuit and the fin pinch decreased, as increasing Reynolds number.

휜이 부착된 수직(垂直) 냉각관(冷却管)에서의 열전달(熱傳達)에 관(關)한 실험적(實驗的)인 연구(硏究) (An experimental study on heat transfer of finned vertical cooling tube)

  • 송하진;이채문;임장순
    • 태양에너지
    • /
    • 제4권2호
    • /
    • pp.43-49
    • /
    • 1984
  • Experiments were performed to study freezing on a finned vertical tube when either conduction in the solid or natural convection in a liquid controls the heat transfer. Conduction is the controlling mode when the liquid is at its fusion temperature, whereas natural convection controls when the liquid temperature is above the fusion value. The liquid was housed in a cylinderical containment vessel whose surface was maintained at a uniform, time-invariment temperature during a data run, and the freezing occurred on a finned vertical tube positioned along the axis of the vessel. The phase change medium was n-octacosan, a paraffin which freezes at about $61^{\circ}C$. For conduction-controlled freezing, the enhancement of the frozen mass due to finning is greatest when the frozen layer is thin and decrease as the layer grows thicker. The degree of enhancement is generally less than the surface area ratio of the finned and unfinned tube.

  • PDF

확대모형을 이용한 휜-관 열교환기의 휜 형상 및 휘 간격 변화에 따른 공기측 성능에 관한 연구 (A study on airside performance of finned-tube heat exchanger according to fin combination and fin pitch variation of using large scale model)

  • 변주석;전창덕;이진호;김진우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.281-287
    • /
    • 2005
  • This study investigates the pressure drop and heat transfer characteristics of heat exchanger according to the combination of fin configuration and fin pitch of each row by the similitude experiments with the finned-tube geometry scaled as large as four times Finned-tube heat exchanger has 2 rows, and fin geometry consists of two cases, louver-louver and louver-slit. Fin pitch is varied with three types in each case, 6-6 mm, 8-8 mm and 8-6 mm. Results show that total heat transfer can be occurred evenly at each row by varying the fin pitch of 1st row and 2nd row. Heat transfer rate and pressure drop characteristics change according to the combination for fin geometry and fin pitch.

  • PDF

150 RT급 흡수식 열펌프용 고온재생기의 열전달 특성 (The heat transfer characteristics of a desorber for 150 RT absorption heat pump)

  • 박찬우;정종수
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.369-376
    • /
    • 1999
  • Experiments were carried out to study the heat transfer characteristics of a disrober for 150 RT LiBr-water absorption heat pump. An experimental apparatus was divided into four sections, a combustion chamber area, two bare-tube areas, and finally a finned-tube area to quantify the heat transfer rate of each section by measuring the generation rate of vapor. Dividing plates was installed at the upper inside part of deserter to prohibit the moving of vapor generated at heating tubes of a section to another section near. In the first bare-tube area, the generation rate of vapor was the largest among the four sections. The finned-tube area only contributed to give sensible heat increase of solution to the saturation temperature. The heat transfer area of the finned-tube area was 52.2%, which absorbed only 9.2% of the total heat from the combustion gas. On the contrary, the heat transfer area of the first bare-tube area was 16.6%, but it absorbed 52.4% of the total absorbed heat. The temperature of the solution at upper part at the finned-tube area was lower than that of the lower part, because weak solution came in upper part of the finned-tube area. But, this tendency was changed at the first and second bare-tube area due to the vigorous heat transfer and fluid flow enhanced by vapor generation through heating tubes. The overall heat transfer coefficient and heat flux were the largest at the first bare-tube area among the other sections.

  • PDF

터보 냉동기용 핀 튜브에 관한 연구(II) - 비등 열전달에 관하여 - (A Study on Finned Tube Used in Turbo Refrigerator(II) - on boiling heat transfer -)

  • 한규일;김시영;조동현
    • 수산해양교육연구
    • /
    • 제5권2호
    • /
    • pp.119-127
    • /
    • 1993
  • This work studies for heat transfer and pressure drop performance of integral inner and outer fin tubes, designed to enhance the heat transfer performance of smooth tubes for in recipro and turbo refrigerator or high performance compact heat exchangers. Eight different inner spiral fin copper tubes with integral fin at outside surfaces were employed to improve boiling heat transfer coeffcient. For comparison, tests were made using a plain tube having the inside diameter and an outside diameter equal to that at the root of the fins for the finned tubes. Pool boiling heat transfer is investigated experimentally and theoretically on single tube arrangement. The refrigerant evaporates at a saturation state of 1 bar on the outside tube surface heated by hot water. The refrigerant R11 ($CFCl_3$) was used at a pressure of $P_s=1bar$ as a convenient test fluid with a boiling temperature of $T_s=23.6^{\circ}C$. The observed heat transfer enhancement of boiling for finned tubes significantly exceeded that to be expected on grounds of increased area. The maximum Vapor - side enhancement(i.e., vapor - side heat transfer coefficient of finned tube/vapor - side coefficient for plain tube) was found to be around 4 at 1299fpm - 30grooves tube.

  • PDF