• 제목/요약/키워드: Finite Element Remesh

검색결과 6건 처리시간 0.02초

실리콘 중공 가스켓의 대변형에 관한 연구 (A Study on the Large Deformation of Silicon Rubber Gasket with Hollow Circular Section)

  • 이태원
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.150-157
    • /
    • 2003
  • In this paper, the large deformation of hollow silicon rubber gasket is treated. The frictional contact occurs between groove and the outer part of hollow gasket, and the frictional self-contact exists in the inner parts of hollow gasket. The silicon rubber has the nonlinear elastic behavior and its material property is approximately incompressible. Hence, the stress analysis requires an existence of a strain energy function, which is usually defined in terms of invariants or stretch ratio such as generalized Mooney-Rivlin and Ogden model. Considering large compressive deformation and friction, Mooney-Rivlin 3rd model and Coulomb's friction model are assumed. The numerical analysis is obtained by the commercial finite element program MARC. But, due to large deformation, the elements degenerate in the inner parts of hollow gasket. This means that the analysis of subsequent increments is carried out with a very poor mesh. In order to continue the analysis with a sufficient accuracy, it is necessary to use new finite element modeling by remesh. Experiments are also performed to show the validity of present method. As a conclusion, numerical results by this research have good agreements with experiments.

3차원 유한요소법을 이용한 교정용 마이크로임플란트 식립 시의 피질골 스트레인 해석 (Cortical bone strain during the placement of orthodontic microimplant studied by 3D finite element analysis)

  • 남옥현;유원재;경희문
    • 대한치과교정학회지
    • /
    • 제38권4호
    • /
    • pp.228-239
    • /
    • 2008
  • 식립 후 힘의 부하가 조기에 이루어지는 마이크로임플란트의 경우 식립 시의 골응력 혹은 스트레인의 관리가 그 안정성에 있어 중요한 요인으로 작용할 수 있다. 이에 본 연구에서는 3D 유한요소법을 사용하여 교정용 마이크로임플란트 식립 시 피질골에 발생하는 응력(스트레인)을 해석하였다. 0.9 mm 직경으로 미리 드릴링한 1mm 두께 피질골에 마이크로임플란트(AbsoAnchor SH1312-7, Dentos, Daegu, Korea)가 식립되는 전체 과정(10회전, 식립 깊이 5 mm)의 모사를 위해 총 1,800 step의 유한요소해석을 실시하였다. 식립 진행과 더불어 생기는 나사산 주위 피질골의 기하학적 형상변화를 유한요소해석에 반영하기 위하여 지속적인 remesh를 실행하였으며, 빠른 수렴을 위해 마이크로임플란트는 강체로, 피질골은 강소성체로 모델링하였다. 해석 결과, 마이크로임플란트 식립 시 피질골에 발생되는 스트레인은 임플란트 주위골 전체에서 정상적인 골개형을 위한 한계치로 보고되고 있는 $4,000\;{\mu}$-strain을 상회하였고, 나사산 첨부 인접골에서는 스트레인이 100% 이상에 달하였다. 계산된 피질골 식립토오크는 약 1.2 Ncm 정도로 가토 경골에 동일 모델의 마이크로임플란트을 식립하며 측정한 값에 약간 미달하였으나 근접한 수치를 보였다. 본 연구를 통해, 마이크로임플란트의 식립과정을 3D 유한요소법으로 재현할 수 있음을 확인하였고, 또한 마이크로임플란트 식립에 의해 피질골에 발생하는 스트레인 크기는 생리적인 골개형을 저해할 수 있는 수준임을 확인할 수 있었다.

들로네이-보로노이 삼각요소생성기법에 있어서 인접성유지와 요소재생성과정을 위한 단순알고리즘 연구 (A SIMPLE ALFORITHM FOR MAINTAINING ACJACENCY AND REMESHENG PROECSS IN DELAUNAY-VORONOII TRIANGULATION)

  • 송영준
    • 전산구조공학
    • /
    • 제6권3호
    • /
    • pp.99-112
    • /
    • 1993
  • 유한요소생성기법중 삼각요소를 생성하는 들로네이-보로노이 기법은 반복되는 국지적 요소재편을 통하여 요소망을 완성하는 기법으로 적응유한요소법의 적용에 이점이 되고 있다. 이 방법의 요체는 재편대상이 되는 요소군의 형성과 이를 대체하는 요소생산의 과정이다. 이를 간편하게 해결하는 방법으로 요소의 인접성을 나타내는 행렬을 새로이 도입하고 이에 따르는 단순 알고리즘을 제시하여 일반 PC급 이용자들도 본 요소생성기법을 이용한 적응유한요소해석의 실질적인 적용가능성을 제고하였다.

  • PDF

레이저 유리 접합 공정의 유한요소해석 (Finite Element Analysis of Laser Class Bonding Process)

  • 홍석관;강정진;변철웅
    • 한국레이저가공학회지
    • /
    • 제11권3호
    • /
    • pp.10-15
    • /
    • 2008
  • This study is aimed to analyse the laser glass bonding process numerically. Due to the viscoelastic behaviour of glass, the extremely large deformation of the frit seal is resulted continuously over the transition temperature, so that the thermal boundary condition be changed in the entire calculation process. The commercial FEM algorithm is restrictively able to remesh the large geometrical boundary shape and to adapt the boundary conditions simultaneously. According to our manual adaptation of increasing the laser line intensity to 700 mW/mm, it is possible to estimate the thermal glass bonding process under the fracture stress in principle. But it should be studied further in the case of high laser line intensity.

  • PDF

Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석 (Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant)

  • 박진서;유원재;경희문;권오원
    • 대한치과교정학회지
    • /
    • 제39권4호
    • /
    • pp.203-212
    • /
    • 2009
  • 골밀도가 높고 두꺼운 피질골에 마이크로임플란트를 self-drilling 방식으로 식립하는 경우 과도한 수준의 골부하 (bone loading)가 발생할 위험이 있으며 이는 인접골의 정상적인 골개형(bone remodeling)에 장애를 초래할 수 있다. 이에, 본 연구에서는 유한요소해석으로 두께 1.0 mm의 피질골에 Absoanchor SH1312-7 마이크로임플란트((주)덴토스, 대구, 대한민국)가 self-drilling 방식으로 식립되는 과정(10회전, 식립깊이 5 mm)을 모사(simulation)하였으며 식립 단계별로 피질골에 발생되는 스트레인을 조사하였다. 식립중 마이크로임플란트 첨부의 절삭연(cutting flute)에 의한 골삭제로 생기는 나사길(threaded groove)의 치수를 얻기 위하여 가토 경골에 마이크로임플란트를 식립/제거한 후 Micro CT (Explore Locus RS, GE Healthcare, Ontario, Canada)를 이용하여 기하형상을 측정하였으며 이를 치밀골의 유한요소모델에 반영하였다. 해석결과, 치밀골에 발생되는 스트레인은 임플란트 식립깊이에 따라 증가하였고, 초기단계에서 나사산에 인접한 골에 국한되던 과부하 부위(스트레인이 4,000${\mu}$-strain을 상회하는 영역)가 식립깊이 증가에 따라 인접골 전체, 즉 나사산 인접부는 물론 골(valley) 부위에 접하는 모든 영역으로 확장되었다. 본 연구를 통해, self-drilling 방식으로 마이크로임플란트를 식립할 때 치밀골에 발생하는 스트레인 크기는 생리적인 골개형을 저해할 수 있는 수준임을 확인할 수 있었다.

p-Version 유한요소법에 의한 형상 최적화설계 (Shape Optimal Design by P-version of Finite Element Method)

  • 김행준;우광성
    • 대한토목학회논문집
    • /
    • 제14권4호
    • /
    • pp.729-740
    • /
    • 1994
  • h-version 유한요소법에 근거를 둔 형상최적화 설계에서는 초기모델의 기하형상에 대한 이상적인 체눈설계가 최종해석시에는 적합하지 않을 수 있게 된다. 그러므로, 최적화의 반복단계마다 모델의 단변형상에 대한 새로운 체눈설계가 필요하게 된다. 그러나 p-version 유한요소법은 형상최적화 문제 해석을 위한 매우 매력적인 대안으로 제시될 수 있다 p-version 유한요소법은 h-version 유한요소법과 비교하여 다음과 같은 큰 장점을 갖고 있다. 첫째로, 보간함수의 차수가 3차이상이 되면 요소의 찌그러진 형상에 대한 유한요소 해에 별 영향을 미치지 않는다. 둘째로, 심지어 응력특이 문제도 h-version에 비해 p-version은 적절한 체눈설계를 하게되면 훨씬 효율적이다. 셋째로, 초지 체눈설계와 최종 체눈설계가 동일하므로 반복단계마다 새롭게 체눈설계를 할 필요가 없어진다. Bezier의 곡선보간법, 경사투사법과 적분형 르장드르 다항식에 기초를 둔 2차원 형상최적화를 위한 p-version 모델이 제시되었다. 수치해석 경과는 p-version 소프트웨어인 RASNA를 사용하여 수행되었다.

  • PDF