• 제목/요약/키워드: Finite Element (FE)

검색결과 1,859건 처리시간 0.023초

Assessment of cold-formed steel screwed beam-column conections: Experimental tests and numerical simulations

  • Merve Sagiroglu Maali;Mahyar Maali;Zhiyuan Fang;Krishanu Roy
    • Steel and Composite Structures
    • /
    • 제50권5호
    • /
    • pp.515-529
    • /
    • 2024
  • Cold-formed steel (CFS) is a popular choice for construction due to its low cost, durability, sustainability, resistance to high environmental and seismic pressures, and ease of installation. The beam-column connections in residential and medium-rise structures are formed using self-drilling screws that connect two CFS channel sections and a gusset plate. In order to increase the moment capacity of these CFS screwed beam-column connections, stiffeners are often placed on the web area of each single channel. However, there is limited literature on studying the effects of stiffeners on the moment capacity of CFS screwed beam-column connections. Hence, this paper proposes a new test approach for determining the moment capacity of CFS screwed beam-column couplings. This study describes an experimental test programme consisting of eight novel experimental tests. The effect of stiffeners, beam thickness, and gusset plate thickness on the structural behaviour of CFS screwed beam-column connections is investigated. Besides, nonlinear elasto-plastic finite element (FE) models were developed and validated against experimental test data. It found that there was reasonable agreement in terms of moment capacity and failure mode prediction. From the experimental and numerical investigation, it found that the increase in gusset plate or beam thickness and the use of stiffeners have no significant effect on the structural behaviour, moment capacity, or rotational capacity of joints exhibiting the same collapse behaviour; however, the capacity or energy absorption capacities have increased in joints whose failure behaviour varies with increasing thickness or using stiffeners. Besides, the thickness change has little impact on the initial stiffness.

Hole 클린칭을 이용한 고장력강판과 Al6061 이종소재의 접합 (Joining High-Strength Steel and Al6061 Sheet Using Hole Clinching Process)

  • 안남식;이찬주;이정민;고대철;이선봉;김병민
    • 대한기계학회논문집A
    • /
    • 제36권6호
    • /
    • pp.691-698
    • /
    • 2012
  • 일반적인 클린칭 접합공정에서 고장력강과 알루미늄의 이종소재간의 접합시 고장력강의 낮은 연신율과 높은 강도로 인해 클린칭 접합시 파단이 발생하거나 높은 클린칭 접합하중이 요구된다. 이러한 문제점을 해결하기 위해 본 연구에서는 클린칭 접합시 고장력강의 변형없이 알루미늄의 변형만을 이용한 홀 클린칭 접합공정을 개발하였다. 고장력강에 홀가공을 적용하여 고장력강의 변형을 배제하였다. 홀 클린칭 접합의 요구접합강도를 기초로 클린칭 접합의 기하학적 구속량을 결정하였으며, 홀 클린칭 금형의 형상은 성형체적 일정조건을 이용하여 설계하였다. 설계된 클린칭 접합공정의 유효성을 평가하기 위해 유한요소해석을 수행하여, 홀 클린칭 접합이 가능함을 확인하였다. 또한 홀 클린칭 접합의 접합강도는 인장전단시험을 통하여 평가하였다. 홀 클린칭 접합강도는 2.56kN으로 요구접합강도와 비교하여 동등수준 이상의 값을 가짐을 확인하였다.

공간 지반 정보를 활용한 이차원 분지 모델링 기반의 국내 홍성 지역에서의 부지 지진 응답 평가 (Assessment of Seismic Site Response at Hongseong in Korea Based on Two-dimensional Basin Modeling using Spatial Geotechnical Information)

  • 선창국
    • 지질공학
    • /
    • 제19권1호
    • /
    • pp.15-23
    • /
    • 2009
  • 지진 시 지반 운동의 증폭과 관련되는 부지 효과는 지하 토사 조건 및 지질 구조에 따라 매우 큰 영향을 받는다. 본 연구에서는 국내 홍성 지역을 대상으로 시추 조사와 현장 탄성파 시험을 포함한 현장 조사 및 지표 부근 지질 정보를 획득하기 위한 부지 답사를 통해 부지 효과를 확인하였다. 홍성 지역은 1978년 계기 지진이 발생한 지역으로서 기반암 상부에 최대 45 m 두께의 풍화 지층이 분포한다. GIS 기법 기반의 지반 정보 시스템을 연구 대상 지역의 공간 지층 구조를 효율적으로 확인하기 위하여 구축하였으며, 이로부터 홍성 지역이 얕고 넓은 분지 형상임을 확인하였다. 홍성 지역의 부지 지진 응답을 평가하기 위하여 대표 단면에 대한 이차원 유한 요소 해석을 수행하였다. 도출된 지진 응답 결과로부터 지반 운동이 기반암 상부 토사층을 톰해 전단파가 전파되면서 증폭되고 분지 형상에 따른 전단파의 상호 작용으로 생성된 표면파로 인해 분지 경계 부근 진동 지속 시간이 증가됨을 확인하였다. 뿐만 아니라, 분지 내의 선정된 토사 부지들에 대해서 추가적인 일차원 유한 요소 지진 응답 해석을 수행하였으며, 본 연구 대상 분지가 매우 얕고 넓음에 따라 분지 경계 부근을 제외하고는 분지 내 대부분의 위치에서 이차원 지진 응답과 유사한 결과를 보였다.

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

Structural performance evaluation of a steel-plate girder bridge using ambient acceleration measurements

  • Yi, Jin-Hak;Cho, Soojin;Koo, Ki-Young;Yun, Chung-Bang;Kim, Jeong-Tae;Lee, Chang-Geun;Lee, Won-Tae
    • Smart Structures and Systems
    • /
    • 제3권3호
    • /
    • pp.281-298
    • /
    • 2007
  • The load carrying capacity of a bridge needs to be properly assessed to operate the bridge safely and maintain it efficiently. For the evaluation of load carrying capacity considering the current state of a bridge, static and quasi-static loading tests with weight-controlled heavy trucks have been conventionally utilized. In these tests, the deflection (or strain) of the structural members loaded by the controlled vehicles are measured and analyzed. Using the measured data, deflection (or strain) correction factor and impact correction factor are calculated. These correction factors are used in the enhancement of the load carrying capacity of a bridge, reflecting the real state of a bridge. However, full or partial control of the traffic during the tests and difficulties during the installment of displacement transducers or strain gauges may cause not only inconvenience to the traffic but also the increase of the logistics cost and time. To overcome these difficulties, an alternative method is proposed using an excited response part of full measured ambient acceleration data by ordinary traffic on a bridge without traffic control. Based on the modal properties extracted from the ambient vibration data, the initial finite element (FE) model of a bridge can be updated to represent the current real state of a bridge. Using the updated FE model, the deflection of a bridge akin to the real value can be easily obtained without measuring the real deflection. Impact factors are obtained from pseudo-deflection, which is obtained by double-integration of the acceleration data with removal of the linear components on the acceleration data. For validation, a series of tests were carried out on a steel plategirder bridge of an expressway in Korea in four different seasons, and the evaluated load carrying capacities of the bridge by the proposed method are compared with the result obtained by the conventional load test method.

앵커지지 흙막이 벽체의 합리적인 3차원 수치해석기법 적용에 관한 연구 (A Study on the Rational Application of 3D Numerical Analysis for Anchored Earth Retaining Wall)

  • 정상섬;심재욱;이성준
    • 한국지반공학회논문집
    • /
    • 제32권4호
    • /
    • pp.29-39
    • /
    • 2016
  • 본 연구에서는 경사지층에 설치된 앵커지지 흙막이 벽체의 거동분석에 있어서 2차원 및 3차원 유한요소해석을 이용하여 굴착심도(H), 굴착폭(L) 및 지반조건의 영향에 따른 수치해석방법의 정확성 및 적용성에 대하여 비교분석하였다. 폐합단면이 아닌 선형방향으로 설치된 흙막이 벽체의 굴착면을 따라서 지층의 변화가 급격한 구간에서 2개의 단면을 선정하여 2차원 유한요소해석을 수행하였으며, 이 2개의 단면을 포함하는 전체 구간의 3차원 유한요소해석을 수행하여 그 결과를 현장계측결과 및 탄소성해석결과와 비교분석하였다. 또한, 3차원 유한요소해석시 굴착심도(H)와 굴착폭(L)의 변화가 흙막이 벽체의 거동에 미치는 영향을 평가하기 위하여 굴착심도와 굴착폭을 변화시켜 해석을 수행하였다. 경사지층에 설치된 앵커지지 흙막이 벽체의 거동분석을 위한 2차원 및 3차원 유한요소 해석 결과, 굴착면을 따라서 길이방향 지반조건 변화의 영향을 3차원 수치해석을 통하여 확인할 수 있었으며, 2차원 해석과 3차원 해석은 지반조건 및 굴착심도에 따라 차이가 있음을 알 수 있었다. 해석대상 지반이 암반이 지배적인 조건인 경우 2차원 및 3차원 수치해석 결과는 모두 실측값과 유사한 결과를 나타냈다. 그러나 암반에 비해 강성이 낮은 토사지반이 지배적인 조건에 있어서 일정심도(20m) 이상의 고심도 지반굴착에 따른 흙막이 벽체의 거동분석 시 2차원 해석결과와 3차원 해석결과는 큰 차이를 나타내고 있었다. 또한 굴착폭(L)의 변화에 따른 거동분석 결과, 보다 정확한 3차원 수치 해석을 위해서 굴착폭(L)의 해석영역을 일정범위(굴착심도의 2배) 이상으로 설정하는 것이 적합할 것으로 판단된다. 이와 같이 흙막이 벽체의 거동분석 및 안정성 검토시에는 지반의 기하학적인 비대칭성과 3차원 구조로 설치되는 흙막이 벽체 및 지보재의 특성을 고려한 3차원 수치해석 기법의 적용이 적절함을 알 수 있었다.

SMART 원자로 제어봉 구동 장치의 동특성해석 (Dynamic Characteristics on the CRDM of SMART Reactor)

  • 이장원;조상순;김동옥;박진석;이원재
    • 대한기계학회논문집A
    • /
    • 제34권8호
    • /
    • pp.1105-1111
    • /
    • 2010
  • 한국원자력연구원은 전력생산과 해수담수화를 동시에 수행하고 친환경적인 SMART 원자로를 개발하였다. SMART 원자로의 여러 구조물 중에 제어봉 구동 장치(CRDM)는 제어봉의 삽입 량을 조절하여 원자로의 출력을 조정하고 비상시 제어봉을 긴급 삽입하여 원자로를 정지시키기 위한 기기이다. 본 연구의 목적은 제어봉 구동 장치의 구조적 건전성을 확보하기 위해서 동특성해석을 수행하는 것이다. 또한 향후 내진해석에 활용될 단순모델의 활용을 위해 상세모델과의 비교, 검증을 수행하였다. 해석은 유한요소 해석기법을 활용하였고 상용해석 프로그램인 ABAQUS 와 ANSYS V12 를 사용하였다. 유한요소 해석모델은 상세모델인 3-D Solid 모델과 단순모델인 Beam 모델을 작성하여 비교하였고 추가로 단순모델을 오일러 보인 Beam4 요소와 티모센코 보인 Beam188 요소로 작성하여 비교 검토하였다. 향후 SMART 원자로집합체의 단순모델을 작성하여 내진해석 등 다양한 해석에 활용될 계획이므로 단순모델은 상세모델과의 오차를 줄이기 위해서 모델 보정(model updating)이 수행되었다.

고장력 볼트 기둥-기초 연결부의 강도특성에 관한 해석적 연구 (An Analytical Study on the Strength Behavior of Column-Foundation Connection with High Tension Bolts)

  • 황동아;황원섭;함준수;정진일
    • 한국강구조학회 논문집
    • /
    • 제28권2호
    • /
    • pp.121-128
    • /
    • 2016
  • 고장력 볼트를 적용한 원형단면 콘크리트 충전 강재 기둥-기초 연결부의 합리적인 설계범위를 제안하기 위하여 축하중과 수평하중을 동시에 받는 기둥-기초 연결부의 전반적인 구조적 거동과 설계변수에 따른 거동특성을 상용 유한요소해석 프로그램인 ABAQUS를 이용하여 해석적으로 검토하였다. 이를 위해 앵커볼트를 고장력 볼트로 대신하는 선행연구의 실험을 토대로 수치해석을 실시하였으며, 해석방법의 타당성을 검증하였다. 또한 현행 설계기준을 분석하여 기둥-기초 연결부 거동에 영향을 미치는 설계변수(앵커의 묻힘깊이, 앵커의 강종, 리브의 높이, 리브의 두께)를 선정하였으며, 설계변수에 따른 기둥-기초 연결부의 거동특성을 비교 분석하였다. 일반 앵커에 비해 고장력 볼트를 적용하는 것이 기둥-기초 연결부의 거동에 유리한 것으로 나타났으며, 고장력 볼트의 최소 묻힘깊이는 기둥 직경(D)을 기준으로 0.5D이상으로 설계하는 것이 합리적이라고 판단된다. 리브의 높이는 0.5D이상, 리브의 두께는 베이스플레이트 두께($t_b$)를 기준으로 $0.4t_b$이상으로 설계하는 것이 합리적이라고 판단된다.

중심가새골조의 순단면 파단에 관한 해석적 연구 (Analytical Study of Net Section Fracture in Special Concentrically Braced Frames)

  • 유정한
    • 한국강구조학회 논문집
    • /
    • 제21권1호
    • /
    • pp.63-70
    • /
    • 2009
  • 파괴모드는 저항력과 비탄성 변형 능력의 저하를 일으키는 균열이나 파단으로 귀결된다. 특수중심가새골조의 잠재적 파괴모드는 가새의 균열이나 파단, 가새나 거싯 플레이트의 순단면 파단, 거싯 플레이트용접의 균열, 볼트의 전단균열, 블록전단파단, 그리고 거싯 플레이트의 좌굴 등을 포함하고 있다. HSS 튜브가새는 특수중심가새골조에 자주 사용되고, 가새의 순단면 파단은 거싯 플레이트가 가새로 삽입되는 홈의 끝부분에 가새의 순단면을 통해 발생한다. 이 파괴모드는 인장파괴모드로 분류되고 급격한 강도저하와 취성적인 거동을 보인다. AISC 디자인 규준에선 순단면 보강을 요구하고 있다 (AISC 2001). 이 논문에서, 순단면 보강의 필요성에 대해 논의한다. 먼저, 미국 버클리대학교에서 수행됐던 순단면 파단실험을 유한요소모델을 이용한 이 실험의 모델링을 통해 소개한다. 실제 골조에서의 순단면 파단의 가능성을 조사하기 위해, 홈이 있는 중심가새골조를 유한요소법을 이용 모델링 하고, 인장지배의 근거리지진 이력을 적용시킨다. 이는 이력이 순단면 파단의 가장 중요한 인자라는 이전 해석 결과에서 기인한 것이다. 순단면 보강의 필요성과 인장지배의 근거리지진 이력의 영향에 대해 조사한다.

원자로 상부헤드 제어봉구동장치 관통노즐 형상이 J-Groove 용접잔류응력에 미치는 영향 (Effects of Geometry of Reactor Pressure Vessel Upper Head Control Rod Drive Mechanism Penetration Nozzles on J-Groove Weld Residual Stress)

  • 김주희;김윤재;이성호;허남용;배홍열;오창영;김지수;박흥배;이승건;김종성;허남수
    • 대한기계학회논문집A
    • /
    • 제35권10호
    • /
    • pp.1337-1345
    • /
    • 2011
  • 가압경수로형 원자로의 원자로압력용기 상부헤드에는 많은 제어봉구동장치(CRDM) 노즐이 분포한다. 최근 10 여 년 동안 제어봉구동장치 alloy 600 CRDM 노즐에서 균열 발생 사례가 증가하고 있으며, 이는 용접과 연관성이 매우 깊은 것으로 알려져 있다. CRDM 노즐에서 발생하는 축 및 원주방향 균열은 유럽과 미국의 원자력 발전소에서 발견되었으며, 사고의 원인은 용접 잔류응력 및 작용하중에 기인하는 일차수응력부식균열(PWSCC)임이 확인되었다. 이러한 이유로 본 연구에서는 유한요소해석을 통해 한국형 원자로의 CRDM 관통 노즐 용접부를 대상으로 용접 잔류응력을 예측하였으며, 특히, 관통노즐의 위치와 형상, 용접부 필렛 형상 및 인접노즐 용접에 의한 영향을 분석하였다.