• Title/Summary/Keyword: Finite Different Method

Search Result 2,301, Processing Time 0.027 seconds

Analysis of Electromagnetic Scattering by a Resistive Strip Grating with Tapered Resistivity on Dielectric Multilayers (다층 유전체위의 변하는 저항율을 가진 저항띠 격자구조에 의한 전자파 산란 해석)

  • Uei-Joong Yoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.5
    • /
    • pp.495-503
    • /
    • 1997
  • In this paper, the E-polarized electromagnetic scattering problems by a resistive strip grating with tapered resistivity on 3 dielectric layers are analyzed to find out the effects for the tapered resistivity of resistive strip and the relative permittivity and thickness of 3 die- lectric layers by applying the Fourier-Galerkin moment methods. The induced surface current density is expanded in a series of Jacobi-polynomial ${P^{(\chi,\beta)}}_p$(.) of the order $\alpha$= 0 and $\beta$=1 as a kind of orthogonal polyomians, and the tapered resistivity assumes to vary linearly from 0 at one edge to finite resistivity at the other edge. The normalized reflected and transmitted powers are obtained by varying the tapered resistivity and the relative permittivity and thickness of dielectric layers. The sharp variation points are observed when the higher order modes are transferred between propagating and evanescent modes, and in general the local minimum positions occur at less grating period for the more relative permittivity of dielectric layers. It should be noted that the patterns of the normalized reflected and transmitted powers for the tapered resistivity are very much different from those of the uniform resistivity and perfectly conducting cases. The proposed method of this paper cna solve the scattering problems for the tapered resistive, uniform resistive, and PEC strip cases.

  • PDF

Damage Study on the Mechanical Fastening in Laminated Composites (복합적층판(復合積層板)의 기계적(機械的) 체결부(締結部)에 관한 파손연구(破損硏究))

  • Kwan-Hyung,Song
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.27 no.4
    • /
    • pp.58-66
    • /
    • 1990
  • A series of test was performed measuring the failure strength and failure mode of Gr/Pi, $[0^{\circ}/45^{\circ}/90^{\circ}/-45^{\circ}]_s$ laminate containing a single pin loaded hole. The finite element method is applied to calculate the stress distribution in the laminates, then the failure load and the failure mode were predicted by means of the characteristic length. 12 different geometric variations were developed to analyze the effects of the ratio of specimen width to hole diameter (W/d) and ratio of edge distance to hole diameter (L/d). X-Ray of NDE methods were utilized in finding out the initial defects, damage and the fracture mechanism, and SEM(Scanning Electron Microscopes) was used the evaluation of the fracture mechanism and crack propagation around hole under tension pin loading. $[0^{\circ}/45^{\circ}/90^{\circ}/-45^{\circ}]_s$ laminate are found to be most sensitive to W/d but not so influenced by L/d. The failure mode and tensile strength predicted by the model show agreement with experiment data for pin loading bolted jointed test except range of $L/d{\leqq}3$.

  • PDF

Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration (디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동)

  • Park, Jung-Hoon;Choi, Nak-Sam
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.125-132
    • /
    • 2020
  • The polymerization shrinkage behavior of dimethacrylate-based composite (Clearfil AP-X, Kuraray) and silorane-based composite (Filtek P90, 3M ESPE) used for dental composite restorations was measured using digital image correlation method. The stress distribution on the surface of specimen was calculated by finite element analysis with equivalent elastic modulus and was compared with the measured shrinkage distribution. Camera images were monitored by a CCD camera during and after the irradiation of light. As a result of the DIC analysis, a non-uniform shrinkage distribution was observed in both composite resins, and the resin core inside the ring specimen had free flowability, leading to in greater shrinkage strain than the resin/ring interfacial region. It was observed that as the distance from the center of the resin increased, the radial average shrinkage strain decreased. The radial average shrinkage strain during light irradiation occurred to be 33% for P90 and 57% for AP-X of the entire strain at the end of the test. The shrinkage behavior of P90 and AP-X was measured to be significantly different from each other during light irradiation. In the resin near the resin/ring interface, it was confirmed that the tensile strain rapidly formed to increase after light irradiation, causing a tensile stressed, interface weak.

The Determination of the Duration of Electroconvulsive Therapy-Induced Seizure Using Local Standard Deviation of the Electroencephalogram Signal and the Changes of the RR Interval of Electrocardiogram

  • Kim, Eun Young;Yoo, Cheol Seung;Jung, Dong Chung;Yi, Sang Hoon;Chung, In-Won;Kim, Yong Sik;Ahn, Yong Min
    • Korean Journal of Biological Psychiatry
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Objectives In electroconvulsive therapy (ECT) research and practice, the precise determination of seizure duration is important in the evaluation of clinical relevance of the ECT-induced seizure. In this study, we have developed computerized algorithms to assess the duration of ECT-induced seizure. Methods Subjects included 5 males and 6 females, with the mean age of 33.1 years. Total 55 ECT sessions were included in the analysis. We analyzed the standard deviation of a finite block of electroencephalography (EEG) data and the change in the local slope of RR intervals in electrocardiography (ECG) signals during ECT-induced seizure. And then, we compared the calculated seizure durations from EEG recording (EEG algorithm) and ECG recording (ECG algorithm) with values determined by consensus of clinicians based on the recorded EEG (EEG consensus), as a gold standard criterion, in order to testify the computational validity of our algorithms. Results The mean seizure durations calculated by each method were not significantly different in sessions with abrupt flattened postictal suppression and in sessions with non-abrupt flattened postictal suppression. The intraclass correlation coefficients (95% confidence interval) of the three methods (EEG algorithm, ECG algorithm, EEG consensus) were significant in the total sessions [0.79 (0.70-0.86)], the abrupt flattened postictal suppression sessions [0.84 (0.74-0.91)], and the non-abrupt flattened postictal suppression sessions [0.67 (0.45-0.84)]. Correlations between three methods were also statistically significant, regardless of abruptness of transition. Conclusions Our proposed algorithms could reliably measure the duration of ECT-induced seizure, even in sessions with non-abrupt transitions to flat postictal suppression, in which it is typically difficult to determine the seizure duration.

Modeling of the Charge-discharge Behavior of a 12-V Automotive Lead-acid Battery (차량용 12-V 납축전지의 충·방전 모델링)

  • Kim, Ui Seong;Jeon, Sehoon;Jeon, Wonjin;Shin, Chee Burm;Chung, Seung Myun;Kim, Sung Tae
    • Korean Chemical Engineering Research
    • /
    • v.45 no.3
    • /
    • pp.242-248
    • /
    • 2007
  • For an optimal design of automotive electric system, it is important to have a reliable modeling tool to predict the charge-discharge behaviors of the automotive battery. In this work, a two-dimensional modeling was carried out to predict the charge-discharge behaviors of a 12-V automotive lead-acid battery. The model accounted for electrochemical kinetics and ionic mass transfer in a battery cell. In order to validate the modeling, modeling results were compared with the experimental data of the charge-discharge behaviors of a lead-acid battery. The discharge behaviors were measured with three different discharge rates of C/5, C/10, and C/20 at operating temperature of $25^{\circ}C$. The batteries were charged with constant current of 30A until the charging voltage reached to a predetermined value of 14.24 V and then the charging voltage was kept constant. The discharge and charge curves from the measurements and modeling were in good agreement. Based on the modeling, the distributions of the electrical potentials of the solid and solution phases, the porosity of the electrodes, and the current density within the electrodes as well as the acid concentration can be predicted as a function of charge and discharge time.

A Study on Topographic Effects in 2D Resistivity Survey by Numerical and Physical Scale Modeling (수치 및 축소모형실험에 의한 2차원 전기비저항 탐사에서의 지형효과에 관한 연구)

  • Kim Gun-Soo;Cho In-Ky;Kim Ki-Ju
    • Geophysics and Geophysical Exploration
    • /
    • v.6 no.4
    • /
    • pp.165-170
    • /
    • 2003
  • Recently, resistivity surveys have been frequently carried out over the irregular terrain such as mountainous area. Such an irregular terrain itself can produce significant anomalies which may lead to misinterpretations. In this study, topographic effects in resistivity survey were studied using the physical scale modeling as well as the numerical one adopting finite element method. The scale modeling was conducted at a pond, so that we could avoid the edge effect, the inherent problem of the scale modeling conducted in a water tank in laboratory. The modeling experiments for two topographic features, a ridge and a valley with various slope angles, confirmed that the results by the two different modeling techniques coincide with each other fairly well for all the terrain models. These experiments adopting dipole-dipole array showed the distinctive terrain effects, such that a ridge produces a high apparent resistivity anomaly at the ridge center flanked by zones of lower apparent resistivity. On the other hand, a valley produces the opposite anomaly pattern, a central low flanked by highs. As the slope of a terrain model becomes steeper, the terrain-induced anomalies become stronger, and moreover, apparent resistivity can become even negative for the model with extremely high slope angle. All the modeling results led us to the conclusion that terrain effects should be included in the numerical modeling and/or the inversion process to interpret data acquired at the rugged terrain area.

Assessment of Equivalent Heights of Soil for the Lateral Earth Pressure Against Retaining Walls Due to Design Truck Load (표준트럭하중에 의해 옹벽에 작용하는 수평토압의 등가높이 산정)

  • Kim, Duhwan;Jin, Hyunsik;Seo, Seunghwan;Park, Jaehyun;Kim, Dongwook;Chung, Moonkyung
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.119-128
    • /
    • 2018
  • Limit state design has been implemented in Korea since 2015; however, there exists no specification of lateral load determination on retaining wall due to the Korean standard traffic load on retaining wall's backfill surface. The lateral load from traffic depends on lane number, standard truck's axle loads and locations, loading distance from the inner wall. The concept of equivalent height of soil accounting for traffic loadings is typically used for design of retaining walls to quantify the traffic loads transmitted to the inner wall faces. Due to the different characteristics of the standard design trucks between Korea and US (AASHTO), the direct use of the guidelines from AASHTO LRFD leads to incorrect estimation of traffic load effects on retaining walls. This paper presents the results of evaluation of equivalent height of soil to reflect the Korean standard truck, based on the findings from analytical solutions using Bounessq's theory and numerical assessment using 2D finite element method. Consequently, it was found that the equivalent heights of soil from the Korean standard truck load were lower for lower retaining wall height.

An Aerodynamic Modeling and Simulation of a Folding Tandem Wing Type Aerial Launching UAV (접이식 직렬날개형 공중투하 무인비행체의 공력 모델링 및 시뮬레이션)

  • Lee, Seungjin;Lee, Jungmin;Ahn, Jeongwoo;Park, Jinyong
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.4
    • /
    • pp.19-26
    • /
    • 2018
  • The aerial launching UAV(Unmanned Aerial Vehicle) mainly uses a set of folding tandem wings to maximize flight performance and minimize the space required for mounting in a mothership. This folding tandem wing has a unique aerodynamic problem that is different from the general type of fixed wing aircraft, such as the rear wing interference problem caused by the wing of the front wing wake and vortex, and the imbalance of the pivot moment applied to the front and rear wings when the wing is deployed. In this paper, we have modeled and simulated various cases through computational fluid dynamics based on the finite volume method and analyzed various aerodynamic phenomena of the tandem wing type aircraft. We find that the front wing shall be installed higher than the rear for minimizing the wake influence and the rear wing can be deployed faster than the front because of the pivot moment due to aerodynamic forces. Also, considering the pivot moment due to aerodynamic force, the rear wing can be deployed much faster than the front wing. Therefore, it is necessary to consider it when developing the wing deploy mechanism.

Estimation of Structural Safety for PolyEthylene (PE) Floating Platforms with API & AISC Standards (API & AISC 기준을 적용한 PolyEthylene (PE) 부유식 플랫폼의 구조 안전성 검토)

  • Seo, Kwang-Cheol;Nam, Taek-Kun;Park, Joo-Shin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.2
    • /
    • pp.237-243
    • /
    • 2019
  • Floating platforms made of PE (PolyEthylene) are often located in shallows of seas, rivers or lakes. They are widely used for marine pensions, marine pontoons, marine bridges, etc. These products are characterized by good flexibility, recyclability, chemical resistance and weatherability with corrosion resistance. Existing PE floating platforms have a simple structure in which one pipe is fastened to one bracket, but this has limited application, even if a user modifies the arrangement. Therefore, we developed a structure that allows buoyancy pipes of various sizes to be fastened to one bracket and verified the structural safety of the product using the finite element method. From the results of structural analysis for buoyancy pipes of different diameters, the maximum stress ratio was 0.78 compared with allowable criteria of 1.0, which represented sufficient safety for a model with 500 mm diameter pipes. Based on the results of this study, further research to evaluate the structural safety of various floating platforms can be carried out in the further; it will also be necessary to establish related evaluation criteria.

Numerical Analysis of Effect of Waveform Micropile on Foundation Underpinning During Building Vertical Extension Remodeling (수치해석을 통한 수직증축 리모델링시 파형 마이크로파일의 보강효과 분석)

  • Wang, Cheng-Can;Jang, Youngeun;Kim, Seok-Jung;Han, Jin-Tae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.39 no.2
    • /
    • pp.335-344
    • /
    • 2019
  • Micropiles are widely used for foundation underpinning to enhance bearing capacity and reduce settlement of existing foundation. In this study, the main objective is to evaluate underpinning performance of a newly developed micropile called waveform micropile for foundation underpinning during vertical extension. Finite element method (FEM) was used to evaluate the underpinning performance of waveform micropile in terms of load-settlement response of underpinned foundation and load sharing behavior. For comparison, underpinning effects of three conventional micropiles with different lengths were also discussed in this study. Numerical results of load-settlement response for single pile demonstrated that bearing capacity and axial stiffness of waveform micropiles were higher than those of conventional micropiles because of the effect of shear keys of waveform micropiles. When additional loads 20 %, which is according to design loads of the vertical extension, were applied to the underpinned foundation, load sharing capacity of waveform micropile was 40 % higher than conventional micropile at the same size. The waveform micropile also showed better underpinning performance than the conventional micropile of length 1~1.5 times of waveform micropile.