• 제목/요약/키워드: Finger Tip

검색결과 124건 처리시간 0.021초

A Case of Solitary Glomus Tumor (단발성 사구종양 1례)

  • Cho, Hae-Ook;Shin, Dong-Hoon;Choi, Jong-Soo;Kim, Ki-Hong
    • Journal of Yeungnam Medical Science
    • /
    • 제13권1호
    • /
    • pp.152-157
    • /
    • 1996
  • We report a case of subungual solitary glomus tumor in a 28-year-old female, who has suffered from pain and tenderness of the left 4th finger tip for about 5 years. Simple surgical excision was performed for removal of the tumor mass and for the relief of the subjective symptoms. No recurrence has been observed for 5 months following excision of the tumor.

  • PDF

A Wearable Interface for Tendon-driven Robotic Hand Prosthesis (건구동식 로봇 의수용 착용형 인터페이스)

  • Jung, Sung-Yoon;Park, Chan-Young;Bae, Ju-Hawn;Moon, In-Hyuk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제16권4호
    • /
    • pp.374-380
    • /
    • 2010
  • This paper proposes a wearable interface for a tendon-driven robotic hand prosthesis. The proposed interface is composed of a dataglove to measure finger and wrist joint angle, and a micro-control board with a wireless RF module. The interface is used for posture control of the robotic hand prosthesis. The measured joint angles by the dataglove are transferred to the main controller via the wireless module. The controller works for directly controlling the joint angle of the hand or for recognizing hand postures using a pattern recognition method such as LDA and k-NN. The recognized hand postures in this study are the paper, the rock, the scissors, the precision grasp, and the tip grasp. In experiments, we show the performances of the wearable interface including the pattern recognition method.

Design and PID Control of Myoelectronic Hand considering Human Vibration (인체진동을 고려한 다관절 전동의수의 설계와 PID제어)

  • 장대진;김명회;양현석;백윤수;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.746-751
    • /
    • 2002
  • This purpose of this study was to design the effect of recovering of a hand amputees by myoelectronic hand. It was designed with 2 degree of freedom in tile laboratory. Myoelectronic hand had only one degree of freedom and one movement until now. Also this myoelectronic hand had multi-joint system. Myoelectronic hand data was obtained by measuring hand and data was applied when it was designed myoelectronic hand. PID controll of myoelectronic hand was used to it. Displacement control was applied the first link of finger. Experiment was accomlkished in Tip grasp, power grasp and Hook grasp modes. Displacement controll was good in low frequency. Velocity control was applied to each mode. This myoelectronic hand with a hand amputees could do some jobs such as grasping materials. Further studies were needed to evaluate the effect of a myoelectronic hand with more precise laboratory equipment.

  • PDF

Non-invasive Blood Glucose Measurement by a Portable Near Infrared (NIR) System (휴대용 근적외선 분광분석기를 이용한 비침투 혈당 측정)

  • 강나루;우영아;차봉수;이현철;김효진
    • YAKHAK HOEJI
    • /
    • 제46권5호
    • /
    • pp.331-336
    • /
    • 2002
  • The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector; which was developed by a microchip technology based on the lithography. Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100 ∼ 1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/dL. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near infrared system.

A Stability Effect of Passive Compliance on Active Compliance Control (수동 Compliance가 능동적 Compliance제어의 안정도에 미치는 영향)

  • Chung, Tae-Sang
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • 제39권1호
    • /
    • pp.92-106
    • /
    • 1990
  • Active compliance is often used in the control of robot manipulators for the implementation of complex tasks such as assembly, multi-finger fine motion, legged-vehicle adaptive control,etc. This technique balances the interactive force between the manipulator tip and its working environment with its position and velocity errors to achieve the operation of a damped spring. This paper investigates the effecft of passive compliance on system stability with regard to force feedback implementation for actively compliant motion. Usually it is understood that accurate position control require a stiff system. However, theoretical examination of control experiments on a legged suspension vehicle suggests that, if the control includes discrete-time force feedback, some passive compliance is necessssary at the legs of the vehicle for system stability. This can be an important factor to bl considered in manipulator design and control. A theoretical analysis, numerical simulation, and experimental result, confirming the above conclusion, are introduced in this paper.

  • PDF

Arterialized Venous Free Flap at the Insufficient Vascular Recipient Bed in Finger Reconstruction (수지 재건시 불충분한 혈행상태의 수혜부에 시행한 동맥화 정맥 유리 피판술)

  • Lee, Young-Keun;Park, Ki-Tae;Lee, Jun-Mo;Park, Hyuk
    • Archives of Reconstructive Microsurgery
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 2012
  • Purpose: Arterialized venous flap is useful for reconstruction of the traumatic soft tissue defect in fingers, but insufficient circulation of the traumatic fingers makes surgeons annoying to use the flap. We have grafted flaps in 7 fingers with insufficient vascular bed hoping to expanded the category of the flap. Materials and Methods: Arterialized venous flap have transplanted in 7 fingers from March 2008 through February 2010 and followed up for 4 to 16 months(average 7.2 months). They were all male with a mean age at the time of surgery was 33. The main injury was crushing in 4 degloving, contact burn and saw injury was I respectively. Time interval from injury to flap transplantation was average 3.1. weeks(3 days to 6 weeks). Designed flap size ranges from $8cm{\times}3.5cm$to $4cm{\times}3cm$. Vessel type of flap was one artery with two veins were 5 cases and one artey with one vein 2. Flap type was cutaneous in 3, tendocutaneous 2, neurotendocutaneous 1 and neurocutaneous 1. The circulation state of recipient site was avascular in 2 cases, insufficiency 3 and tip avascular 2. Results: Arterialized venous flap was complete survived in 2 cases, partial necrosis(less than 10%) 3 and failed in 2. Conclusion: An arterialized venous free flap could be a useful procedure for reconstruction in soft tissue or combined defect of the finger despite an avascular or insufficient vascular beds if the recipient beds were free from infection.

  • PDF

A Study on the Extraction of Nail's Region from PC-based Hand-Geometry Recognition System Using GA (GA를 이용한 PC 기반 Hand-Geometry 인식시스템의 Nail 영역 추출에 관한 연구)

  • Kim, Young-Tak;Kim, Soo-Jong;Park, Ju-Won;Lee, Sang-Bae
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • 제14권4호
    • /
    • pp.506-511
    • /
    • 2004
  • Biometrics is getting more and more attention in recent years for security and other concerns. So far, only fingerprint recognition has seen limited success for on-line security check, since other biometrics verification and identification systems require more complicated and expensive acquisition interfaces and recognition processes. Hand-Geometry has been used for biometric verification and identification because of its acquisition convenience and good performance for verification and identification performance. Hence, it can be a good candidate for online checks. Therefore, this paper proposes a Hand-Geometry recognition system based on geometrical features of hand. From anatomical point of view, human hand can be characterized by its length, width, thickness, geometrical composition, shapes of the palm, and shape and geometry of the fingers. This paper proposes thirty relevant features for a Hand-Geometry recognition system. However, during experimentation, it was discovered that length measured from the tip of the finger was not a reliable feature. Hence, we propose a new technique based on Genetic Algorithm for extraction of the center of nail bottom, in order to use it for the length feature.

The Effects of Regular Jjimjilbang Exposure on Cold Tolerance in Young and Elderly Females (정기적인 찜질방노출이 청년과 노년 여성의 내한성에 미치는 영향)

  • Choi, Jeong-Wha;Song, Eun-Young;Hwang, Soo-Kyung
    • The Korean Journal of Community Living Science
    • /
    • 제18권4호
    • /
    • pp.599-607
    • /
    • 2007
  • We analyzed the effects of regular Jjimjilbang (Korean sauna) exposure on the cold tolerance in young and elderly females. Subjects were young (n=7) and elderly (n=7) females who had never had Jjimjilbang exposure experience. The Jjimjil training group was exposured in the Jjimjilbang 19 times per week. Jjimjibang exposure was limited to three times per day. Jjimjil activity was taken freely. To prove the effects of the cold tolerance, subjects were exposed to cold air ($12{\pm}1^{\circ}C,\;60{\pm}10%$RH). In these conditions, subjects were exposed for 30 minutes at which time rectal temperature, skin temperatures, clothing microclimate, energy expenditure, blood pressure and subjective sensation were measured. To prove the effects of the local cold tolerance, vascular hunting reaction was observed measuring the finger skin temperature while the left middle finger tip was immersed in cold water of $0^{\circ}C$ for 30 minutes. The results are as follows. According to repeated Jjimjil exposure, rectal temperature changes, peripheral temperature and energy expenditure were increased gradually in the cold climate chamber. Blood pressure, subjective sensation and vascular hunting reactions did not show any significant difference. In conclusion, regular Jjimjilbang exposure has negative effects on the ability of the body to improve its regulation of temperature especially in cold tolerance.

  • PDF

Peripheral Arterial Bypass using Interpositional Vein Graft in the Hypothenar Hammer Syndrome: A Case Report (소지구 망치증후군에서 정맥이식을 이용한 동맥우회술: 증례 보고)

  • Kim, Jeong Hong;Eun, Seok Chan;Heo, Chan Yeong;Baek, Rong Min;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • 제36권1호
    • /
    • pp.89-92
    • /
    • 2009
  • Purpose: The clinical syndrome of unilateral finger ischemia, caused by digital artery occlusions from embolization from the palmar ulnar artery associated with repetitive striking of the palm, has been called the hypothenar hammer syndrome (HHS). We report the case of a man with this unique disease probably caused by manual work. Methods: A 52 - year - old male left - hand dominant manual worker complained of pain and coldness in the left 4,5th finger. On physical examination, there was a tip necrosis and the result of Allen's test was mildly positive(sluggish filling of hand from the ulnar artery). Arteriograms confirmed occlusion of the distal ulnar artery without direct perfusion of the superficial palmar arch and distal digital artery. Surgical bypass with reverse autologous vein grafting was performed between ulnar artery and superficial palmar arch, common digital artery. Results: He had an uneventful postoperative course and has remained asymptomatic for 18 months since discharge. Patency has been confirmed by color doppler with resolution of cold intolerance and successful digital preservation. Conclusion: We introduce very unique pattern of vascular ischemic disease and recommend the arterial bypass with vein interpositional grafting.

Effect of Acupuncture at the LU5(Reinforcement), LU10(Reduction) on the Pulsation Scale of Chon, Gwan and Chuk region using High Resolution Infrared Camera (척택.어제 침자가 고해상도 적외선 카메라로 관찰한 촌구맥 부위의 온도 Pulsation 변화에 미치는 영향 연구)

  • Na, Chang-Su;Jeon, Hyo-Sang;Kim, Jee-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • 제32권2호
    • /
    • pp.127-133
    • /
    • 2011
  • Arteria radialis is a branch of the brachial artery extending down the forearm around the wrist where it closes to skin surface. In the oriental medicine, the skin above arteria radialis has an important role because oriental medicine practitioners put their finger tips on the area, and diagnose patient's health conditions by feeling the pulsation of the arterial contraction. The finger tip diagnostic method relies on subjective decision of the practitioner; and there is a need to develop an objective diagnostic modality. The pulsation of the arterial contraction appears not only a movement on the site but also as temperature fluctuation due to pulsatile feeding of warmer blood. The goal of this study is to demonstrate a feasibility of using an infrared camera quantitatively to detect the temperature fluctuation on the skin. Clinical important three different areas, called chon, gwan, chuk, near a wrist where the arteria radialis reaches close to skin surface are marked with small pieces of surgical tape. A high-speed and high-resolution infrared camera with a 3 cm of field of view measures these areas for 10 second at 200 frames per second with a 320*240 pixel size. The pulsatile temperature fluctuation is calculated after passing a band pass filter to remove any stationary temperature over 10 second. The temperature fluctuation of a healthy male volunteer is measured at a room temperature as a control, and is compared with another measurement performed after 20 minutes staying in a room at a 40 degree Celsius. This comparison is repeated for three times, and indicates that the fluctuation increases after staying 20 minutes in the warm room. This increase becomes smaller when the person stays in the warm room with an acupuncture treatment that decreases body temperature. So that an objective diagnostics on the site may become feasible.