• 제목/요약/키워드: Finger Pressure

검색결과 136건 처리시간 0.026초

압력손실시험을 이용한 막 완결성 평가에서 초기압력 및 UCL 도출인자 민감도 분석 (Sensitivity Analysis of Initial Pressure and Upper Control Limit on the Pressure Decay Test for Membrane Integrity Evaluation)

  • 이주희;홍승관;허현철;이광제;최영준
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.793-800
    • /
    • 2008
  • Recently domestic drinking water industry has recognized membrane-based technology as a promising alternative for water treatment. To ensure successful application of membrane processes, the integrity of membrane systems should be maintained. According to US EPA guidance, the pressure decay test based on the bubble point theory is recommended to detect any membrane defection of which size is close to the smallest diameter of Cryptosporidium oocysts, $3{\mu}m$. Proper implementation of the pressure decay test is greatly affected by initial test pressure, and the interpretation of the test results is associated with upper control limit. This study is conducted to investigate various factors affecting determination of initial test prtessure and upper control limit, including membrane-based parameters such as pore shape correction factor, surface tension and contact angle, and system-based parameters, such as volumetric concentration factor and total volume of system. In this paper, three different hollow fibers were used to perform the pressure decay test. With identical initial test pressure applied, their pressure decay tendency were different from each other. This finding can be explained by the micro-structure disparity of those membranes which is verified by FESEM images of those membranes. More specifically, FESEM images revealed that three hollow fibers have asymmetry, deep finger, shallow finger pore shape, respectively. In addition, sensitivity analysis was conducted on five parameters mentioned above to elucidate their relation to determination of initial test pressure and upper control limit. In case of initial pressure calculation, the pore shape correction factor has the highest value of sensitivity. For upper control limit determination, system factors have greater impact compared to membrane-based parameters.

추나요법이 요부통증에 미치는 효과 - 점혈(点穴)법을 중심으로 - (Effects of Chuna Therapy on the Low Back Pain - Focusing on the Finger Pressure Therapy of Acupuncture Point -)

  • 박형수
    • 한국콘텐츠학회논문지
    • /
    • 제9권9호
    • /
    • pp.243-248
    • /
    • 2009
  • 요통을 주소로 내원한 환자 74명(실험군 37명, 대조군 37명)을 대상으로 추나요법 중 점혈법이 요통환자의 통증감소에 미치는 효과를 알아보기 위하여 시각적 상사척도(VAS)의 도구를 이용하여 전방굴곡, 전방굴곡 후 신전, 좌 우 측방굴곡시 각각의 통증정도를 측정하여 대조군(근피신경전기자극군)과 비교 실험하였다. 수집된 자료는 SPSS WIN 12.0 프로그램으로 이용하여 ANCOVA 검정을 하였다(p<0.05). 통증정도(VAS)는 실험군이 대조군 보다 실험 전 후 감소 정도가 통계적으로 유의한 차이가 있는 것으로 나타났다(p<0.05). 실험군에서의 점혈법 실시 전 후 요통정도를 비교한 결과 전방굴곡에서는 실험군이 1.92정도 통증이 감소하였고, 전방굴곡 후 신전에서는 실험군이 2.22정도 통증이 감소하였으며, 우측굴곡에서는 실험군에서 1.23정도 감소하였고, 좌측굴곡에서는 실험군이 1.21정도 통증이 감소함을 보였다. 즉, 사전 통증정도를 모두 같게 고정을 한 후에 점혈법을 받은 실험군은 근피신경전기자극을 받은 대조군보다 통증정도가 유의하게 감소하였다.

스크류 펌프 디스펜싱 인쇄를 이용한 결정질 실리콘 태양전지 전면전극 제작에 대한 연구 (Study on Front Side Metallization of Crystalline Silicon Solar Cells Using a Screw Pumped Dispenser)

  • 정혜욱;신동윤
    • 대한기계학회논문집B
    • /
    • 제41권5호
    • /
    • pp.365-372
    • /
    • 2017
  • 결정질 실리콘 태양전지의 전면전극은 수광면적을 극대화하면서도 전기적 저항을 최소화하기 위하여 미세하면서도 높은 종횡비로 형성되어야 한다. 기존의 전면전극 형성공정은 스크린 인쇄가 이용되었으나, 스크린 제판 개구부의 선폭보다 인쇄된 전극의 선폭이 1.3~2.2 배 넓게 형성되는 문제 때문에 $40{\mu}m$ 급 미만의 미세전극을 형성하기 위해서는 스크린 제판의 개구부는 $30{\mu}m$ 이하여야 한다. 그러나, 개구부가 미세화될수록 인쇄압력의 증가, 실버 페이스트 전이 불량률 상승 및 메쉬 마크로 인한 전극의 전기적 저항 상승과 같은 문제들이 발생한다. 본 연구에서는 스크린 인쇄를 대체하기 위한 차세대 인쇄방식으로서 스크류 펌프방식의 디스펜싱 인쇄를 소개하고, 기존 인쇄방식과 차별화되는 점들에 대해 논의하도록 한다.

접촉력 및 미끄러짐을 감지 가능한 촉각 센서의 개발 (Development of Tactile Sensor for Detecting Contact Force and Slip)

  • 최병준;강성철;최혁렬
    • 대한기계학회논문집A
    • /
    • 제30권4호
    • /
    • pp.364-372
    • /
    • 2006
  • In this paper, we present a finger tip tactile sensor which can detect contact normal force as well as slip. The sensor is made up of two different materials, such as polyvinylidene fluoride (PVDF) known as piezoelectric polymer, and pressure variable resistor ink. In order to detect slip on the surface of the object, two PVDF strips are arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, a tactile sensing system is developed, which includes miniaturized charge amplifier to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

Development of Fingertip Tactile Sensor for Detecting Normal Force and Slip

  • Choi, Byung-June;Kang, Sung-Chul;Choi, Hyouk-Ryeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1808-1813
    • /
    • 2005
  • In this paper, we present the finger tip tactile sensor which can detect contact normal force as well as slip. The developed sensor is made of two different materials, such as polyvinylidene fluoride(PVDF) that is known as piezoelectric polymer and pressure variable resistor ink. In order to detect slip to surface of object, a PVDF strip is arranged along the normal direction in the robot finger tip and the thumb tip. The surface electrode of the PVDF strip is fabricated using silk-screening technique with silver paste. Also a thin flexible force sensor is fabricated in the form of a matrix using pressure variable resistor ink in order to sense the static force. The developed tactile sensor is physically flexible and it can be deformed three-dimensionally to any shape so that it can be placed on anywhere on the curved surface. In addition, we developed a tactile sensing system by miniaturizing the charge amplifier, in order to amplify the small signal from the sensor, and the fast signal processing unit. The sensor system is evaluated experimentally and its effectiveness is validated.

  • PDF

20대 남성의 아래팔 손목 건영역과 근육영역 가압이 손가락 혈류속도에 미치는 효과 (Effects of Pressurization on Finger's Blood Velocity of Tendon and Muscle Areas in Forearm of 20's male)

  • 김남임;홍경희
    • 한국의류산업학회지
    • /
    • 제21권4호
    • /
    • pp.488-496
    • /
    • 2019
  • This study investigated if the proper pressure level on the wrist tendon area and muscle area of the lower arm are within the same range by examining the responses of blood flow and subjective evaluation. Subjects consisted of 18 males in their 20s, and the experimental bands were custom-made by applying size measurements of each subject. In the experiment, a total of 5 steps were selected by reducing 10 (Step 1) to 50 (Step 5)% from the original body size in the circumferential direction. Blood flow was measured with a sensor attached to the tip of the finger inside the right hand while sitting in a chair for 15 minutes. Blood velocity began to increase (0.82 kPa) when the wrist circumference around tendon area was reduced by 20% (Step 2) and reached its maximum (1.72 kPa) at Step 4. However, the preferred subjective pressure was 1.36 kPa, which was less than the maximum pressure value of 1.72 kPa for Step 4. Blood velocity began to increase when pressure on the muscle area was 1.38 kPa and reached its maximum at 2.16 kPa; however, the most preferred clothing pressure was 1.71 kPa. The results of this study showed that the appropriate pressure level was higher in the muscle area than in the wrist tendon of the lower arm and indicated that graduated compression is favorable.

Reconstruction of High-Pressure Paint Gun Injection Injured Finger Using Free Flaps with T-Shaped Pedicles and Multiple Venous Anastomoses

  • Lee, Jun Beom;Choi, Hwan Jun;Kim, Jun Hyuk;Cheon, Nam Ju;Lee, Young Man
    • Archives of Reconstructive Microsurgery
    • /
    • 제24권2호
    • /
    • pp.75-78
    • /
    • 2015
  • High-pressure (HP) injection injury to the upper extremity often causes a very serious clinical problem, leading to poor outcomes, including amputation, so that a true surgical emergency is required. The outcomes can be improved with emergent wide surgical debridement. However the diagnosis of these injuries is often delayed due to underestimated evaluation at first appearance and lack of common knowledge of the seriousness of this injury. The type and pressure of the infecting material is an important factor in prognosis and organic solvents infected pressure injury can cause poor outcome and increased amputation rate. In this case, we report on reconstruction of HP oil-based paint injection injuries of the finger using T-shaped pedicles and multiple venous anastomoses. In this concept, arterial flow can be maintained by the reverse flow of distal anastomosis when there is difficulty with the proximal anastomosis. And venous flow can be preserved by deep and superficial vein anastomosis. This concept has various advantages including preserving patency of the pedicle in chronic vasculopathy or trauma cases and maintaining the arterial flow by the reverse flow of distal anastomosis and can improve the free flap survival by a two vascular anastomosis system.

결정질 실리콘 태양전지의 전극 종횡비 개선과 전극 간 간격이 효율에 미치는 영향 분석 (The Analysis on the Effect of Improving Aspect Ratio and Electrode Spacing of the Crystalline Silicon Solar Cell)

  • 김민영;박주억;조해성;김대성;변성균;임동건
    • 한국전기전자재료학회논문지
    • /
    • 제27권4호
    • /
    • pp.209-216
    • /
    • 2014
  • The screen printed technique is one of the electrode forming technologies for crystalline silicon solar cell. It has the advantage that can raise the production efficiency due to simple process. The electrode technology is the core process because the electrode feature is given a substantial factor (for solar cell efficiency). In this paper, we tried to change conditions such as squeegee angle $55{\sim}75^{\circ}$, snap off 0.5~1.75 mm, printing pressure 0.6~0.3 MPa and 1.6~2.0 mm finger spacing. As a result, the screen printing process showed an improved performance with an increased height higher finger height. Optimization of fabrication process has achieved 17.48% efficiency at screen mesh of 1.6 mm finger spacing.

A Secure Authentication Method for Smart Phone based on User's Behaviour and Habits

  • Lee, Geum-Boon
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권9호
    • /
    • pp.65-71
    • /
    • 2017
  • This paper proposes a smart phone authentication method based on user's behavior and habit that is an authentication method against shoulder surfing attack and brute force attack. As smart phones evolve not only storage of personal data but also a key means of financial services, the importance of personal information security in smart phones is growing. When user authentication of smart phone, pattern authentication method is simple to use and memorize, but it is prone to leak and vulnerable to attack. Using the features of the smart phone pattern method of the user, the pressure applied when touching the touch pad with the finger, the size of the area touching the finger, and the time of completing the pattern are used as feature vectors and applied to user authentication security. First, a smart phone user models and stores three parameter values as prototypes for each section of the pattern. Then, when a new authentication request is made, the feature vector of the input pattern is obtained and compared with the stored model to decide whether to approve the access to the smart phone. The experimental results confirm that the proposed technique shows a robust authentication security using subjective data of smart phone user based on habits and behaviors.

고무 도뇨관을 이용한 간단한 수지 지혈대 (A Tunable Digital Tourniquet Using Nelaton Catheter)

  • 김상화;임영민;정성노;권호
    • Archives of Plastic Surgery
    • /
    • 제35권6호
    • /
    • pp.759-761
    • /
    • 2008
  • Purpose: Surgery on digit requires a clear, bloodless field and it can be achieved by using a tourniquet. Several type of tourniquet have been used including Penrose drains and sterile glove with hemostat. We present a simple digital tourniquet using nelaton catheter, which is easily available, inexpensive, easy-to-apply, and effective for digital surgery. Methods: We made a small incision on the opposite side of an opening at the tip of nelaton catheter. Then the other tip of nelaton catheter is passed through the incision to form a ring. Nelaton catheter is placed aournd the base of the injured finger, making a tight circle to desired pressure. Results: A simple tourniquet using nelaton catheter effectively achieves a bloodless field and allows fine control of the pressure for digital surgery. Conclusion: We present a sismple digital tourniquet using nelaton catheter, which is easily available, inexpensive, tunable, and available for more than one finger.