• Title/Summary/Keyword: Fine motion

Search Result 195, Processing Time 0.03 seconds

The Technologic Consideration of Using for DSA (DSA에 대한 기술적 고찰)

  • Cho, Young-Ki
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.13-20
    • /
    • 1994
  • The paper is on the record of radiography the patients with SIEMENS ANGIOSTAR/POLYTRON S PLUS angiosystem with DSA system in the Chonbuk National University Hospital from October 1993 to June 1994. The results are as follow : 1. Among the total No, 836 case of utilization, angiography are 316(37.8 %), interventional radiography are 256(34.2 %), and dacryocystography and sialography are 168(20/1 %). Therefore non-angiogrlphy procedure are incerasing. 2. The aomunt of contrast material used are half as much as conventional angiovascular system. 3. The amount of film consumed are $10{\sim}15%$ of that of conventional angio vascular system and reduction of procedure time are $40{\sim}50%$. 4. Admitting that dignostic utility is in the utilization by examination region, there should be technological study which deal with fine vessel and motion artifact problem.

  • PDF

Development of the Hovering AUV test-bed and field test

  • Choi, Hyeung-Sik;Cho, Sohyung;Kim, Joon-Young
    • Journal of Advanced Research in Ocean Engineering
    • /
    • v.2 no.1
    • /
    • pp.40-47
    • /
    • 2016
  • This paper describes the design and performance of a hovering AUV constructed at KMOU (Korea Maritime and Ocean University). Before the field test, we analyzed the dynamic performance of the AUV using a simulation program made by Matlab & Simulink. Also, a PID controller was designed to control the thrusters. Using 4 thrusters (2 vertical and 2 horizontal), the AUV could be controlled using dynamic motion with 4-DOF. A simulation and field test were conducted with way-point tracking, maintaining the desired depth. To perform way-point tracking, the AUV can be fine-tuned to the desired heading angle through the LOS (Line Of Sight) method. This paper shows the results of simulation and field tests.

Atmospheric Numerical Simulation for an Assessment of Wind Resource and an Establishment of Wind Map on Land (풍력자원 평가 및 육상바람지도 작성을 위한 고해상도 대기유동장 수치모의)

  • Jung, Woo-Sik;Lee, Hwa-Woon;Kim, Hyun-Goo;Choi, Hyun-Jung;Lee, Soon-Hwan;Kim, Dong-Hyuk;Kim, Min-Jung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.529-531
    • /
    • 2009
  • To construct the wind map for mainland Korea, the well designed atmospheric numerical modeling system was used. Three nest domains were construced with spatial resolutions between $10{\times}10km$ up to the hightest resolution of $1{\times}1km$. Parameterization schemes like MRF(PBL), RRTM(radiation), Grell(cumulus) were chosen since wind data simulated is in better agreement with the observed wind data. High-resolution atmospheric numerical model was applied to simulate the motion of the atmosphere and to produce the wind map around the South Korea. The results of several simulations were improved compare to the past system, because of using the fine geographical data, such as terrain height and land-use data, and the meteorological data assimilation.

  • PDF

A Study on the Atomization and Combustion Characteristics of Air-assisted Injector in MPI Engine (MPI 엔진용 공기 보조 인젝터의 분무 미립화 및 연소 특성에 관한 연구)

  • 서영호;이창석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • The spray characteristics of air-assisted fuel injection and its effects on the engine combustion was investigated in this study. The atomization characteristics of a Bosch fuel injector inserted into the air-assist adapter were measured using particle motion analysis system. Droplet size decreased with air supplied and fine spray with below $60\mu\textrm{m}$ of SMD was acquired under the conditions of air-assist pressure over 0.5bar. The lean combustion performance of a 1.8L DOHC engine equipped with air-assist adapters was tested on the dynamometer. When the assistant air pressure is 1.0bar, lean limit recorded the highest value, and CO, HC emissions were decreased at the pressure over 1.0bar.

  • PDF

Robotic Lateral Compartment Selective Neck Dissection in Well-Differentiated Thyroid Carcinoma (갑상선 분화암에서 로봇을 이용한 측경부 림프절 절제술)

  • Tae, Kyung
    • Korean Journal of Bronchoesophagology
    • /
    • v.17 no.2
    • /
    • pp.83-88
    • /
    • 2011
  • Robotic thyroidectomy has been developed to minimize neck scarring, and several authors have described its feasibility and safety, and have reported surgical outcomes comparable with conventional open thyroidectomy. The da Vinci surgical system robot provides a three-dimensional $10-12{\times}$magnified view of the surgical area. It also provides hand-tremor filtration, fine motion scaling, and precise and multi-articulated hand-like motions. Recently, robotic technology has also been applied to lateral compartment neck dissection in thyroid cancer. We have developed a new novel selective neck dissection procedure by a gasless unilateral axillo-breast (GUAB) approach with a da Vinci Surgical System for well-differentiated thyroid carcinoma to avoid a long visible neck scar. Based on our early experience, robotic selective neck dissection by GUAB approach is a safe, feasible and cosmetically excellent procedure. It can be an alternative to conventional open surgery in the highly selected patients with well-differentiated thyroid carcinoma. The oncologic safety of robotic selective neck dissection should be verified with long-term follow-up data.

  • PDF

Simultaneous Positioning and Vibration Control of Chip Mounter with Structural Flexibility (칩마운터 구조물의 유연성을 고려한 위치와 진동 동시 제어)

  • Kang, Min Sig
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.1
    • /
    • pp.53-59
    • /
    • 2013
  • Chip mounter which is used to pick chips from the pre-specified position and place them on the target location of PCB is an essential device in semiconductor and LCD industries. Quick and high precision positioning is the key technology needed to increase productivity of chip mounters. As increasing acceleration and deceleration of placing motion, structural vibration induced from inertial reactive force and flexibility of mounter structure becomes a serious problem degrading positioning accuracy. Motivated from these, this paper proposed a new control design algorithm which combines a mounter structure acceleration feedforward compensation and an extended sliding mode control for fine positioning and suppression of structural vibration, simultaneously. The feasibility of the proposed control design was verified along with some simulation results.

A Study on Rendezvous Point between the Mobile Robot and Predicted Moving Objects (경로예측이 가능한 이동물체와 이동로봇간의 Rendezvous Point에 관한 연구)

  • Youn, Jung-Hoon;Lee, Kee-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.84-86
    • /
    • 2001
  • A new navigation method is developed and implemented for mobile robot. The mobile robot navigation problem has traditionally been decomposed into the path planning and path following. Unlike tracking-based system, which minimize intercept time and moved mobile robot distance for optimal rendezvous point selection. To research of random moving object uses algorithm of Adaptive Control using Auto-regressive Model. A fine motion tracking object's trajectory is predicted of Auto-regressive Algorithm. Thus, the mobile robot can travel faster than the target wi thin the robot's workspace. The can select optimal rendezvous point of various intercept time.

  • PDF

A study on multi degrees of freedom fine motion measurement for milli-structure (밀리구조물의 다자유도 미세 변위 측정법에 대한 연구)

  • 배의원;김종안;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.39-42
    • /
    • 2000
  • Cutrent technological development toward miniaturization requires smaller components. These components usually generate complex multi-DOF motions other than simple 1-DOF motlon. Therefore it is essential to develop measurement methodology for 6-DOF motions. In this paper, a new 6-DOF measurement system for milli-struchlre is presented. This methodology basically employs the Optical Beam Deflection Method (OBDM) with a diffraction grating. A laser beam is emitted toward the difliaction grating which could be attached on the surface of a milli-structue and the incident ray is dif'||'&'||'acted in several directions. Among these difliacted beams, $0^{th}$ and $\pm$ $1^{th}4" order difkicted rays are detected by 4 Quadrant Photodiodes. From coordinate values fram each detector, we can get information for 6-DOF motions with lineariration method, Required resolutions for milli-struchue measurement are suh-micrometer in translation and arcsec in rotation. Experimental results indicate that proposed system has possibility to satisfy this requirement.

  • PDF

Study of Dual Servo System for Measurement System of Mechanical Property (재료의 기계적 물성측정 시험장치를 위한 이중서보 시스템에 관한 연구)

  • 최현석;송치우;한창수;이형욱;최태훈;이낙규;나경환
    • Journal of the Semiconductor & Display Technology
    • /
    • v.2 no.2
    • /
    • pp.31-37
    • /
    • 2003
  • This paper presents a measurement system of mechanical property using dual servo system. There are many kinds of method to measure material properties such as tensile test, indention and bending test. It is highly required to measure the properties of nano-sized material and structure. However, It is need more accurate measurement system, more stable and frequency response than conventional test. In this paper, we designed the dual servo system for a measuring instrument The dual servo system consisting of a coarse stage and a fine motion stage with VCM and PZT is proposed. Mechanical mechanism is designed with the leaf spring type of flexure hinge joint. Lead compensator is applied to this control system, and is designed by PQ method.

  • PDF

Robotic Microsurgery Optimization

  • Brahmbhatt, Jamin V.;Gudeloglu, Ahmet;Liverneaux, Philippe;Parekattil, Sijo J.
    • Archives of Plastic Surgery
    • /
    • v.41 no.3
    • /
    • pp.225-230
    • /
    • 2014
  • The increased application of the da Vinci robotic platform (Intuitive Surgical Inc.) for microsurgery has led to the development of new adjunctive surgical instrumentation. In microsurgery, the robotic platform can provide high definition $12{\times}-15{\times}$ digital magnification, broader range of motion, fine instrument handling with decreased tremor, reduced surgeon fatigue, and improved surgical productivity. This paper presents novel adjunctive tools that provide enhanced optical magnification, micro-Doppler sensing of vessels down to a 1-mm size, vein mapping capabilities, hydro-dissection, micro-ablation technology (with minimal thermal spread-$CO_2$ laser technology), and confocal microscopy to provide imaging at a cellular level. Microsurgical outcomes from the use of these tools in the management of patients with infertility and chronic groin and testicular pain are reviewed. All these instruments have been adapted for the robotic console and enhance the robot-assisted microsurgery experience. As the popularity of robot-assisted microsurgery grows, so will its breadth of instrumentation.