• Title/Summary/Keyword: Fine aggregate modulus

Search Result 120, Processing Time 0.029 seconds

A Study on the Properties of Quality of Concrete Using Mixed Sand Improved Grading (개량입도 혼합모래를 사용한 콘크리트의 품질특성에 관한 연구)

  • Kim Ki-Hoon;Han Min-Cheoi;Park Koo-Byung;Yoon Gi-Won;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.55-58
    • /
    • 2004
  • This paper investigated the results of quality of concrete using mixed sand with grading adjustment in order to find out the applicability of fine aggregate with bad grading, According to test results, fluidity of concrete with fine level grading river sand was decreased while with coarse level grading crushed sand increased compared with that with medium level grading crushed sand. Use of mixed sand with grading adjustment(MSG) resulted in an improvement in fluidity. Increase in fineness modulus led to an increase in bleeding, For compressive strength, use of MSG increased compressive strength. For drying shrinkage, use of fine level grading river sand resulted in an increasing drying shrinkage due to the larger presence of fine particles, while use of MSG led to a reduction in drying shrinkage

  • PDF

Properties and Repair-Reinforcement of Concrete Introduced Crack (균열이 발생된 콘크리트의 특성 및 보수.보강(구조 및 재료 \circled2))

  • 김영익;윤준노;민정기;김경태;박필우;성찬용
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.284-289
    • /
    • 2000
  • This study is performed to evaluate an the crack properties and repair-reinforcement of concrete introduced crack. Materials used are portland cement, coarse aggregate, fine aggregate, unsaturated polyester resin and fly ash. Specimen is used beam of 76${\times}$76${\times}$412mm for measurement of pulse velocity, dynamic modulus of elasticity and bending strength and is introduced crack artificially. The following conclusions are drawn; Pulse velocity, dynamic modulus of elasticity and bending strength of concrete introduced crack is shown the lower 1.24∼11.91%, 3.42∼17.21% and 38.17∼61.0% than that of the control concrete, respectively. Pulse velocity, dynamic modulus of elasticity and bending strength of concrete repaired and reinforced crack is shown the higher 0.5∼2.60%, 1.57∼3.07% and 28.17∼47.25% than that of the concrete introduced crack and the lower than that of the control concrete, respectively.

  • PDF

A Fundamental Study on the Measurement of Fineness Modulus Using CNN-based Deep Learning Model (CNN기반의 딥러닝 모델을 활용한 잔골재 조립률 예측에 관한 기초적 연구)

  • Lim, Sung-Gyu;Yoon, Jong-Wan;Pack, Tae-Joon;Lee, Han Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.50-51
    • /
    • 2021
  • Recently, as concrete is used in many construction works in Korea, the use of aggregates is also increasing. However, the depletion of aggregate resources is making it difficult to supply and demand high-quality aggregates, and the use of defective aggregates is causing problems such as poor performance such as the liquidity and strength of concrete pouring out in the field. As a result, quality tests such as sieve analysis test is conducted on their own, but this study was conducted to improve time and manpower by using the CNN-based Deep Learning Model for the fineness modulus.

  • PDF

An Experimental Study on the Properties of Concrete Block for Revetment Using Recycled Fine Aggregates (재생 잔골재를 이용한 호안블럭의 재료특성에 관한 실험적 연구)

  • 이명규;윤건호;김도현;이근호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.221-224
    • /
    • 2001
  • In this paper, the properties of concrete using recycled fine aggregate are anlyzed. Five different contents. 0%, 40%, 60%, 80% and 100% of recycled concrete were used for this study. At curing 280days, compressive strength, dry-shrinkage, static modulus of elasticity and poission's ratio have been tested according to replacement ratio of recycled fine aggregates.

  • PDF

Effect of Aggregate on Mechanical Properties of Ultra-High Strength Concrete Exposed to High Temperature (고온을 받은 초고강도 콘크리트의 역학적 특성에 관한 골재의 영향)

  • Kim, Young-Sun;Choi, Hyoung-Gil;Ohmiya, Yoshifumi;Kim, Gyu-Yong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.4
    • /
    • pp.431-440
    • /
    • 2011
  • Concrete structures exposed to fire produce changes in their internal structure, resulting in their service life reduction due to the deterioration of its strength and performance capacity. The deterioration level are dependent on the temperature, exposure time, concrete mix proportions, aggregate property, and material properties. This study was performed to evaluate the thermal behavior of ultra-high strength concrete for the parameters of water to cement ratio (compressive strength), fine to total aggregate ratio, and maximum coarse aggregate size. At room temperature and $500^{\circ}C$, tests of ultrasonic pulse velocity, resonance frequency, static modulus of elasticity, and compressive strength are performed using ${\varnothing}100{\times}200\;mm$ cylindrical concrete specimens. The results showed that the residual mechanical properties of ultra-high strength concrete heated to $500^{\circ}C$ is influenced by variation of a water to binder ratio, fine to total aggregate ratio, and maximum coarse aggregate size.

Effect of Recycled Fine Aggregate Quality on Strength Properties of Concrete (순환잔골재 품질에 따른 콘크리트의 강도특성)

  • Jeon, Esther;Yun, Hyun-Do;Jang, Yong-Heon;Choi, Ki-Sun;Bae, Kee-Sun;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.609-612
    • /
    • 2008
  • This study investigated effect of recycled fine aggregate quality on strength properties of concrete. Some investigations have been carried out to study the strength properties of recycled aggregate concrete. But these have some limitation due to small-scale test in the laboratory. Therefore concrete using this study were fabricated by ready-mix concrete. Variables were quality of recycled fine aggregate(high and low quality) and replacement ratio of 0%, 30%, 60%, 100%(high quality), 35, 70%(low quality). The change of air content of recycled aggregate concrete were similar to natural aggregate concrete. Replacement ratio of recycled aggregate was not necessarily correlated with compressive strength and modulus of rupture of recycled aggregate concrete.

  • PDF

Fundamental Properties of Lightweight Concrete with Dry Bottom Ash as Fine Aggregate and Burned Artificial Lightweight Aggregate as Coarse Aggregate (건식 바텀애시 경량 잔골재와 소성 인공경량 굵은골재를 사용한 콘크리트의 기초 특성)

  • Choi, Hong-Beom;Kim, Jin-Man
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.267-274
    • /
    • 2018
  • Though the wet bottom ash has been used as a type of lightweight aggregate, dry bottom ash, new type bottom ash from coal combustion power plant, has scarcely researched. It is excellent lightweight aggregate in the view point of construction material. This study is performed to check the applicability of dry bottom ash as a fine aggregate in lightweight aggregate concrete, by analyzing various properties of fresh and hardened concrete. We get results that the slump of concrete is within the target range at less than 75% replacement rate of dry bottom ash, the air content is not affected by the replacement rate of dry bottom ash, the bleeding capacity is less than $0.025cm^3/cm^2$ at 75% under of the replacement rate of dry bottom ash, and the compressive strength of concrete show 90% or more comparing the base mix while initial strength development is a little low. Oven dry unit weight of concrete is reduced by 8.9% when replaced 100% dry bottom ash, and dry shrinkage tends to decrease depending on increase of replacement rate of dry bottom ash. Modulus of elasticity of concrete shows no decease at 50% over of the replacement rate of dry bottom ash, while modulus of elasticity of concrete decreases when the replacement rate increases further. The dry bottom ash, when used as a fine aggregate in lightweight concrete, can be used effectively without any deterioration in quality.

Fresh and hardened properties of rubberized concrete using fine rubber and silpozz

  • Padhi, S.;Panda, K.C.
    • Advances in concrete construction
    • /
    • v.4 no.1
    • /
    • pp.49-69
    • /
    • 2016
  • This work investigates the mechanical properties of conventional concrete (CC) and self compacting concrete (SCC) using fine rubber and silpozz were accompanied by a comparative study between conventional rubberized concrete (CRC) and self compacting rubberized concrete (SCRC). Fine rubber (FR) from scrap tires has replaced the fine aggregate (FA) and Silpozz has been used as a replacement of cement at the proportions of 5, 10 and 15%. Silpozz as a partial replacement of cement in addition of superplasticiser (SP) increases the strength of concrete. Fresh concrete properties such as slump test, compaction factor test for CRC, whereas for SCRC slump flow, $T_{500}$, V-funnel, L-box, U-box, J-ring tests were conducted along with the hardened properties tests like compressive, split tensile and flexural strength test at 7, 28 and 90 days of curing. The durability and microstructural behavior for both CRC and SCRC were investigated. FR used in the present study is 4.75 mm passing with fineness modulus 4.74.M30 grade concrete is used with a mix proportion of 1:1.44:2.91 and w/c ratio as 0.43. The results indicate that as FR quantity increases, workability of both CRC and SCRC decreases. The results also show that the replacement of natural fine aggregate (NFA) with FR particles decreases the compressive strength with the increase of flexural strength observed upto 5% replacement of FR. Also replacement of cement with silpozz resulted enhancement of strength in SCRC.

An Effect on the Properties of High Flowing Concrete by Materials Variations-Focused on Inchon LNG Receiving Terminal #213,214 Tanks- (사용재료의 품질변동이 고유동콘크리트의 특성에 미치는 영향-인천 LNG 인수기지 #213,214-TK를 중심으로-)

  • 권영호;김무한
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 2000
  • This research investigates experimentally an effect on the properties of the high flowing concrete to be poured in the under-ground slurry wall of Inchon LNG receiving terminal(#213,214-TK) according to variations of concrete materials. Variables for sensitivity test were selected items as followings. 1) Concrete temperature (3cases), 2) Unit water (5cases), 3) Fineness modulus of fine aggregate (5cases), 4) Particle size of lime stone powder (3cases), 5) Replacement ratio of blast-furnace slag (4cases) and 6) Addition ratio of high range water reducing agent (5cases). And fresh conditions of the super flowing concrete should be satisfied with required range including slump flow(65$\pm$5cm), 50cm reaching time of flow(4~10sec), V-lot flowing time(10~ 20sec), U-box height(min. 300mm) and air content(4$\pm$1%). As results for sensitivity test, considered flow-ability, self-compaction and segregation resistance of the high flowing concrete, material variations and conditions of fresh concrete should be satisfied with the range as follwings. 1) Concrete temperature are 10~2$0^{\circ}C$(below 3$0^{\circ}C$), 2) Surface moisture of fine aggregate is within $\pm$ 0.6%, 3) Fineness modulus of fine aggregate is 2.6$\pm$0.2, 4)Replacement ratio of blast-furnace slag is 45~50% and 5) Addition ratio of high range water reducing agent is within 1%. Based on the specification for quality control, we successfully finished concrete pouring on the under-ground slurry wall having 75,000㎥(#213,214-TK) and accumulated real date in site.

A Study on the Properties of Concrete Substituting Copper Slag for Fine Aggregate (잔골재를 동슬래그로 대체한 콘크리트의 특성 연구)

  • Bae, Ju Seong;Kim, Nam Wook;Ko, Sang Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.151-158
    • /
    • 2007
  • The recent government policy for environment is pursuing for a circular waste control system not only to reduce waste as much as possible but also to vigorously use the already produced waste. Copper slag has a higher fineness modulus and a greater specific gravity than natural aggregate. but when the substitutive ratio of fine aggregate is higher than 30%, material segregation occurs by bleeding. Thus, in this study, the strength and the physical properties were tested for the specimens manufactured by varying the types of admixtures, and the substitutive ratio of copper slag to suppress material segregation occurring due to the bleeding of concrete using copper slag as the substitutive material of fine aggregate and to find the adequate substitutive ratio of copper slag.