• 제목/요약/키워드: Fin temperature distribution

검색결과 65건 처리시간 0.026초

내장형 모터와 리니어 모터를 적용한 초고속 수평형 머시닝센터의 열 특성 해석 (Thermal Characteristic Analysis of a High-Speed Horizontal Machining Center with Built-in Motor and Linear Motors)

  • 김석일;조재완
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.416-423
    • /
    • 2004
  • This paper presents the thermal characteristic analysis of a high-speed horizontal machining center with spindle speed of 50,000rpm and feedrate of 120m/fin. The spindle system is designed based on the built-in motor, angular contact ceramic ball bearings, oil-air lubrication and oil-jacket cooling method. The X-axis and Y-axis feeding systems are composed of the linear motors and linear motion guides, and the Z-axis feeding system is composed of the servo-motor, ball screw and linear motion guides. The thermal characteristics such as the temperature distribution, temperature rise, thermal deformation and step response, are estimated based on the finite element model of machining center and the heat generation rates of heat sources related to the machine operation conditions. Especially, the thermal time constant assessed from the step response function is introduced as an index of thermal response characteristics.

  • PDF

통신장비용 앰플리파이어 액체냉각장치 및 냉각유체 분배기의 최적설계 및 성능특성 (Optimum Design of Liquid Cooling Heat Exchangers and Cooling-Fluid Distributors for a Amplifier Cabinet of Telecommunication Equipment)

  • 윤린;김용찬;김현종;최종민;천덕우
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.24-30
    • /
    • 2006
  • Three liquid cooling heat exchangers for cooling of telecommunication equipment were designed and their cooling performances were tested. The liquid cooling heat exchangers had twelve rectangular channels $(5\times3 mm)$ with different flow paths of 1, 4, and 12. Silicon rubber heaters were used to provide heat flux to the test section. Heat input was varied from 75 to 400 W, while flow rate and inlet temperature of working fluid were altered from 1.2 to 4.0 liter/fin and from 15 to 3$30^{\circ}C$, respectively. The 4-path heat exchanger showed lower and more uniform average inner temperatures between heaters and the surface of heat exchanger than those of the others. To obtain optimal distribution of working fluid to each channels of liquid cooling heat exchangers, 2-3-2 and 4-3 type tube distributors were designed, and their distribution performances of working fluid were numerically and experimentally investigated. The distributor of the 2-3-2 type showed superior distribution performance compared with those of the 4-3 type distributor.

착상을 고려한 극저온 질소-대기 열교환기의 해석 (Analysis of a Cryogenic Nitrogen-Ambient Air Heat Exchanger Including Frost Formation)

  • 최권일;장호명
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.825-834
    • /
    • 2000
  • A heat exchanger analysis is performed to investigate the heating characteristics of cryogenic nitrogen by ambient air for the purpose of cryogenic automotive propulsion. The heat exchanger is a concentric triple-passage for supercritical nitrogen, and the radial fins are attached on the outermost tube for the crossflow of ambient air. The temperature distribution is calculated for the nitrogen along the passage, including the real gas properties of nitrogen, the fluid convections and the conductions through the tube walls and the fins. Since the wall temperature of the outer (ambient side) tube is very low in most cases, a heavy frost can be formed on the surface, affecting the heat exchange performance. By the method of the similarity between the heat and the mass transfer of moist air, the frost growth and the time-dependent effectiveness of the heat exchanger are calculated for various operating conditions. It is concluded that the frost formation can augment the heating of nitrogen during the initial period because of the latent heat, then gradually degrades the heat exchange because of the increased thermal resistance. Practical design issues are discussed for the flow rate of nitrogen, the velocity and humidity of ambient air, and the sizes of the fin.

  • PDF

Effects on Refrigerant Maldistribution on the Performance of Evaporator

  • Lee, Jin-Ho;Kim, Chang-Duk;Byun, Ju-Suk;Jang, Tae-Sa
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권2호
    • /
    • pp.107-118
    • /
    • 2005
  • An experimental investigation was made to study two-phase flow distribution in a T-type distributor of slit fin-and-tube heat exchanger using R-22. Experiments were carried out under the conditions of saturation temperature of $5^{\circ}C$ and mass flow rate varying from 0.6 to 1.2kg/min. The inlet air has dry bulb temperature of $27^{\circ}C$, relative humidity of 50% and air velocity varying from 0.63 to 1.71m/s. A comparison was made between the predictions from the previously proposed tube-by-tube method and the present experimental data for the heat transfer rate of evaporator. Results show that $82.5\%$ increase of air velocity is needed for T-type distributor with four outlet branches than that of two outlet branches under the superheat of $5^{\circ}C$, which resulted in increasing of air-side pressure drop of $130\%$ for the former as compared to the latter.

30W급 LED 투광등 설치각도에 따른 히트싱크 온도분포에 관한 연구 (A Study on Heatsink Temperature Distribution according to the Installation Angle of a 30W LED Floodlight)

  • 이영호;이중섭;정한식
    • 한국기계가공학회지
    • /
    • 제18권8호
    • /
    • pp.24-30
    • /
    • 2019
  • This study investigated the heat dissipation characteristics of a heat-sensitive LED. The results of the empirical test showed that the best temperature intensification was found at 90 with 15-fins, and the heatsink installed perpendicular to the direction of the flow of air was directly connected to the air in the largest heat shield area, leading to the best cooling, and the number of fin also resulted increase in the heat discharge area, resulting in the largest cooling action with 15 fins. It was found that the rate of air flow changed in the range of 1.5m/s to 2.5m/s, but only by a deviation of about $2^{\circ}C$ to $3^{\circ}C$ from the current state of 15 fins at 2.5m/s, and the rate of air flow increased, but the performance of the heat release was not significantly increased. As a result wind speed with minimum air flow conditions of 1.5m/s can greatly contribute to the heat dissipation performance.

유한 요소법을 이용한 히트싱크의 성능평가를 위한 열해석 연구 (Thermal Analysis of the Heat Sink Performance using FEM)

  • 이봉구;이민
    • 한국산학기술학회논문지
    • /
    • 제15권9호
    • /
    • pp.5467-5473
    • /
    • 2014
  • 최근 전자 및 기계부품 기술의 발전으로 전자 장비는 더욱 고성능화, 소형화, 다기능화 되면서 시스템 내부에 발생하는 발열부의 온도를 제어하기 위해 히트싱크가 사용된다. 본 연구에서는 내부 터널 구조의 2가지 형상의 히트싱크의 열 성능평가를 유한요소 프로그램인 ANSYS를 이용하여 수치해석 하였다. 수치해석은 자연대류 상태에서의 열 성능을 수치해석으로 비교 분석하여 냉각핀 형상에 따른 열 성능을 평가하였다. 또한 시간에 따른 열전달 특성과 온도분표의 해석결과를 기초로 하여 히트싱크의 성능평가를 예측하였다. 수치해석의 결과, 형상 A 히트싱크가 형상 B의 히트싱크보다 열 전달율이 자연대류에서 약 70% 향상되었다.

열사이클을 적용한 고온 조건 콘크리트 블록의 열용량 특성 (Thermal Energy Capacity of Concrete Blocks Subjected to High-Temperature Thermal Cycling)

  • 양인환;박지훈
    • 한국건설순환자원학회논문집
    • /
    • 제8권4호
    • /
    • pp.571-580
    • /
    • 2020
  • 본 연구에서는 열에너지 저장시스템의 중요한 요소인 저장 매체에 관한 연구를 수행하였다. 열에너지 저장 매체로써 콘크리트는 열적 및 역학적 특성이 우수하며 저렴한 비용으로 인해 다양한 이점을 갖는다. 또한, 강섬유가 혼입된 초고강도 콘크리트는 고인성 및 고강도 특성으로 인해 고온 노출에 우수한 내구성을 나타내며, 강섬유의 높은 열전도율은 축열 및 방열에 유리한 영향을 미친다. 초고강도 콘크리트의 온도분포 특성을 파악하기 위하여 콘크리트 블록을 제작하고 일정한 열사이클을 적용하여 가열실험을 수행하였다. 열유체 흐름에 의한 열전달을 위하여 열전달 파이프를 콘크리트 블록 중심부에 매립하였다. 또한, 열전달 파이프 형상에 따른 온도분포 특성을 비교하기 위하여 핀의 유무에 따라 원형 파이프 및 종방향 핀 부착 파이프를 설정하였다. 열사이클에 따른 온도분포 특성을 분석하고, 이를 토대로 시간에 따른 열에너지 및 누적 열에너지를 산정하여 비교 분석하였다. 열사이클이 반복될수록 강섬유 혼입 초고강도 콘크리트는 고온에 대하여 안정화를 나타내었다. 또한, 온도분포 및 열에너지 산정 결과를 통해 축열 성능을 보유한 것으로 판단되며, 열에너지 저장 매체 역할을 수행할 수 있는 재료로 기대된다.

착상조건에서 R134a와 R1234yf를 적용한 핀-관 형태의 증발기 성능 비교 (Performance Comparison of Fin-Tube Type Evaporator using R134a and R1234yf under the Frost Condition)

  • 신윤찬;김진현;조홍현
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5795-5801
    • /
    • 2015
  • 식생활의 향상 및 다양화로 신선한 제품에 대한 요구가 증가하고 있으며, 이에 따라 냉장 및 냉동식품의 저온유통 또한 점차 증가되고 있다. 현재 냉동산업에는 주로 R134a 냉매가 사용되고 있으며 GWP(Global Warming Potential)가 1300으로써 매우 높아 지구온난화에 영향을 미친다. 이를 대체하기 위한 냉매로써 R1234yf 냉매가 있으며, GWP는 4로써 매우 낮다. 냉동탑차 냉장시스템에 사용되는 증발기는 저온조건에서 작동되기 때문에 서리가 형성되어 시스템의 성능을 급격히 감소시킨다. 따라서, 본 연구에서 R134a와 R1234yf 냉매를 작동유체로 사용한 증발기의 성능을 착상조건 하에서 다양한 운전조건으로 분석하였다. 해석결과, 서리성장 조건에서 공기측 입구온도, 상대습도, 증발온도 변화에 대하여 R134a 증발기의 성능이 R1234yf 증발기보다 더욱 민감하게 나타났으며 서리의 성장 또한 R134a 증발기가 더 크게 나타났다.

$CO_{2}$이용 열펌프의 실외열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Outdoor Heat Exchanger for Heat Pump Using $CO_{2}$)

  • 장영수;이민규;안영산;김영일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2005
  • The purpose of this study is to investigate the performance of outdoor heat exchanger for heat pump using carbon dioxide. Two types of fin and tube heat exchangers (2 rows for type A and 3 rows for B) are tested. Both heat exchangers have counter-cross flow and 1-circuit arrangement. Test results such as heat transfer rate, pressure drop characteristics and temperature distribution in the heat exchanger are shown with respect to mass flow rate of refrigerant and frontal air velocity For cooling mode, the minimum temperature difference between air and refrigerant of type B is smaller than that of type A by $1^{circ}C$, but the pressure loss of air side is much higher for type B by $29\%$. It is found that a large temperature gradient of carbon dioxide during gas cooling Process Promotes thermal conduction through tube wall and fins which results in degradation of heat transfer performance. For heating mode operation, type B heat exchanger shows higher heat transfer performance compared to type A. However, because pressure loss of refrigerant side of type B is much greater than that of type A, the refrigerant outlet pressure of type B becomes lower than that of type A.

낙동강 수계 위천에 서식하는 큰납지리(Acheilognathus macropterus) (Pisces : Cyprinidae)의 초기생활사 (Early Life History of Acheilognathus macropterus (Pisces:Cyprinidae) in the Wicheon Stream of Nakdonggang River)

  • 박재민;한경호
    • 한국수산과학회지
    • /
    • 제56권5호
    • /
    • pp.676-683
    • /
    • 2023
  • The development of the egg, larvae, and juveniles of Acheilognathus macropterus from the Wicheon stream of Nakdonggang River was investigated for early life history characteristics. The fish used in the study were collected from Wicheon stream located in Bian-myeon, Uiseong-gun, Gyeongsangbuk-do. The fertilized egg was 1.88±0.09 mm (n=30) in long diameter and 1.34±0.06 mm (n=30) in short diameter. After fertilization at a water temperature of 20℃, the egg took 31 h and 40 min to hatch. Newly hatched larvae had an average total length of 3.92±0.13 mm (n=30) and possessed a yolk sac the mouth and anus were not developed. Twenty days after hatching, the postflexion larvae had an average total length of 8.08±0.29 mm (n=30), with the tail tip fully bent at 45° and began feeding. Thirty-three days after hatching, the number of fin stems reached an integer with an average total length of 15.0±1.08 mm (n=30). In this study, differences in the egg size, hatching time, melanophore development period, and distribution location were confirmed between A. macropterus and allied species.