• 제목/요약/키워드: Fin systems

검색결과 146건 처리시간 0.031초

CADET를 이용한 가로방향 힘의 Saturation에 대한 미사일의 성능해석 (Covariance analysis describing function technique for missile performance)

  • 김진호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.456-459
    • /
    • 1993
  • CADET is used to analyze the performance of the missile. Miss distance is calculated for a given lateral fin force saturation level due to the aerodynamic characteristics, target acceleration, and glint and fading noises which is assumed as Gaussian noises. As .alpha.-.betha. filter is studied to attenuate the noises, the results are compared with those of without filter. For the easy simulation, the transfer function of a discrete .alpha.-.betha. filter is converted into the continuous model. Simulation results show that the results of CADET simulation is similar to those of Monte-Carlo simulation. Moreover CADET is the better in computing time demand.

  • PDF

아음속 유동에서의 발사체의 공력특성에 관한 실험 연구 (Experimental study on aerodynamic characteristics of launcher at subsonic speed)

  • 노오현;이동호;김원욱;김철완
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.608-613
    • /
    • 1988
  • Subsonic aerodynamic force and moment characteristics have been determined for parametric groups of launchers. Geometric variables considered in the experimental study were body length, nose planform, fin planform (body-alone contained), number of stage and existence of extrnal booster, All data were obtained for angles of attack from 0 to 27 deg in 3-deg. increments.

  • PDF

LQG 설계에 의한 시선지령 유도루우프의 구성 (Command to line of sight guidance loop based on LQG design)

  • 장상근;유준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.567-571
    • /
    • 1992
  • A guidance loop of the missile system which uses a command to line of sight(CLOS) guidance law is designed based on LQG theory. In the environment of the severe tracking system noise, the system requires small aerodynamic control fin travel and small miss distance simultaneously. Results from a sample airframe shows good performance against a randomly maneuvering target.

  • PDF

Design of air-cooled waste heat removal system with string type direct contact heat exchanger and investigation of oil film instability

  • Moon, Jangsik;Jeong, Yong Hoon;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.734-741
    • /
    • 2020
  • A new air-cooled waste heat removal system with a direct contact heat exchanger was designed for SMRs requiring 200 MW of waste heat removal. Conventional air-cooled systems use fin structure causing high thermal resistance; therefore, a large cooling tower is required. The new design replaces the fin structure with a vertical string type direct contact heat exchanger which has the most effective performance among tested heat exchangers in a previous study. The design results showed that the new system requires a cooling tower 50% smaller than that of the conventional system. However, droplet formation on a falling film along a string caused by Rayleigh-Plateau instability decreases heat removal performance of the new system. Analysis of Rayleigh-Plateau instability considering drag force on the falling film surface was developed. The analysis results showed that the instability can be prevented by providing thick string. The instability is prevented when the string radius exceeds the capillary length of liquid by a factor of 0.257 under stagnant air and 0.260 under 5 m/s air velocity.

Histology and Morphometries of the Epidermis of the Fins and Sucking Disc of the Mudskipper, Periophthalmus modestus (Pisces, Gobiidae)

  • Park, Jong-Young;Kim, Ik-Soo;Lee, Yong-Joo;Kim, So-Young
    • Animal cells and systems
    • /
    • 제8권2호
    • /
    • pp.111-115
    • /
    • 2004
  • The epidermis of the mudskipper, Periophthalmus modestus, consists of three layers- the outermost layer, middle layer and stratum germinativum. Extensive fine blood capillaries are present near the superficial layer of epidermis and outermost layer in five fins and a sucking disc. The diffusion distance between the vascular capillaries and the surface of epidermis ranged from 3.6 to 10.9${\mu}$m: 3.6 ${\mu}$m in the sucking disc, 10.9 ${\mu}$m in the anal fin and 4.6 to 5.0 ${\mu}$m in the two dorsal fins. Rate of the surface area of respiratory epithelium, the surface area of the fine blood capillaries occupied per surface area of epidermis in 0.1mm, is 3.7 to 4.4% in two dorsal fins and 1.1% in the anal fin. The middle layer is simpler in structure consisting of small or voluminous cells swollen by epidermal cells, and this layer appeared web-like. Well-developed lymphatic spaces containing lymphocytes existed in the stratum germinativum. The five fins and sucking disc had no epidermal glands.

건식온돌시스템의 전열특성 및 방열성능에 관한 이론적 분석 (Theoretical Analysis on Heat Transfer Characteristics and Heat Flux Performance in Ondol Systems of Dried Type)

  • 장용성;유기형;조동우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.176-181
    • /
    • 2007
  • This study aims to evaluate theoretically heat transfer characteristics and heat flux performance in ondol system of dried type is composed of panel of ceramics to improve of thermal conductivity and fin to expand heat. To this end, we analyzed effect of design factors(temperature of hot water, set temperature of room and thermal conductivity of finishing materials) in ondol system of dried type by heat transfer analysis. The main results of this study are summarized as follows; The deviation of heat flux and temperature was reduced by heat expansion from fin decreasing heat loss generated in air layer. The temperature and heat flux in upper finishing materials surface linearly increased according to temperature increment of hot water, but the temperature distribution in upper surface was assessed uneven. The greater heat resistance value of upper finishing materials, the deviation of maximum temperature and minimum temperature was decreased. Also, we suggested a basic design data about ondol system of dried type through an analysis of simulation results on heat transfer characteristics and heat flux performance.

  • PDF

효과적인 패널 냉각을 위한 대향류형 냉각장치의 개발 (A Development of Counter Flow Type of Cooling System for Effective Panel Cooling)

  • 이중순
    • 한국산학기술학회논문지
    • /
    • 제11권3호
    • /
    • pp.802-807
    • /
    • 2010
  • 산업용 컴퓨터를 포한한 다양한 형태의 공작기계나 자동화 시스템의 배전반이나 제어 패널을 고효율적으로 냉각시킬 수 있는 시스템은 매우 중요한 요소이다. 따라서 이러한 냉각장치는 산업용 로봇, 수치제어 공작기계 등과 같은, 다양한 산업용 시스템에 널리 사용되고 있다. 본 연구에서는 패널 내부를 순환하는 공기를 강제적으로 유동시키는 냉각방식을 채택하여 효과적인 패널 냉각을 위한 대향류형 냉각장치를 개발하였다. 본 연구를 통하여 효과적인 냉각장치를 위한 핀 어셈블리를 개발하여 제어용 패널에 적용한 결과, 기존의 시스템에 비하여 냉각 성능과 열교환율이 개선된 결과를 확인할 수 있었다. 연구에 적용된 상용의 시스템에 비해 공기의 유동량은 약 20% 정도 증가하는 현상을 보였고, 열교환량은 약 2배 이상 증가하는 현상을 확인할 수 있었다.

자동차용 에어컨의 마이크로채널 응축기의 수치적 모델 개발 (Numerical Model Development of a Microchannel Condenser for Mobile Air-Conditioning Systems)

  • 쉐흐리야 이샤크;나비드 울라;최준호;김만회
    • 한국수소및신에너지학회논문집
    • /
    • 제33권4호
    • /
    • pp.430-436
    • /
    • 2022
  • This paper presents the numerical model development of a microchannel heat exchanger in mobile air-conditioning and heat pump applications. The model has been developed based on the effectiveness-NTU method using a segment-by-segment modeling approach. State-of-art correlations are used for refrigerant- and air-side heat transfer coefficients and pressure drops. The calculated heat condenser capacities are in good agreement with experimental data, with an average difference of 1.86%. The current model can be used for microchannel condenser simulations under various operating conditions. It is anticipated to improve productivity in designing and optimizing microchannel heat exchangers with folded louver fin geometry.

Automated measurement and analysis of sidewall roughness using three-dimensional atomic force microscopy

  • Su‑Been Yoo;Seong‑Hun Yun;Ah‑Jin Jo;Sang‑Joon Cho;Haneol Cho;Jun‑Ho Lee;Byoung‑Woon Ahn
    • Applied Microscopy
    • /
    • 제52권
    • /
    • pp.1.1-1.8
    • /
    • 2022
  • As semiconductor device architecture develops, from planar field-effect transistors (FET) to FinFET and gate-all-around (GAA), there is an increased need to measure 3D structure sidewalls precisely. Here, we present a 3-Dimensional Atomic Force Microscope (3D-AFM), a powerful 3D metrology tool to measure the sidewall roughness (SWR) of vertical and undercut structures. First, we measured three different dies repeatedly to calculate reproducibility in die level. Reproducible results were derived with a relative standard deviation under 2%. Second, we measured 13 different dies, including the center and edge of the wafer, to analyze SWR distribution in wafer level and reliable results were measured. All analysis was performed using a novel algorithm, including auto fattening, sidewall detection, and SWR calculation. In addition, SWR automatic analysis software was implemented to reduce analysis time and to provide standard analysis. The results suggest that our 3D-AFM, based on the tilted Z scanner, will enable an advanced methodology for automated 3D measurement and analysis.

배기 열 회수 열교환기 형식이 디젤 엔진 성능에 미치는 영향 (The effect of heat exchanger type for exhaust heat recovery system on diesel engine performance)

  • 김철정;최병철;박권하
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권6호
    • /
    • pp.639-647
    • /
    • 2014
  • 지구 온난화와 화석 연료 고갈로 인해 $CO_2$ 저감과 효율 상승을 동시에 만족하는 기술 개발이 요구된다. 배기 열 회수 기술은 두 가지를 모두 만족할 수 있는 대표적인 기술이다. 본 연구는 배기 열 회수 장치를 위한 세 가지 형식의 증발기용 열교환기를 배기관에 설치하여 실험 및 분석하였다. 고속최대부하에서 판형 열교환기의 배압이 가장 높아지고 실린더 최고 압력이 낮아지며 일산화탄소 배출량도 증가하였다. 또한 고속에서 배압이 2배 이상 증가하며 연료소비율이 2% 증가되어 열교환기 중 가장 높은 증가량을 나타내었다. 핀 튜브 열교환기는 전반적으로 배기 배출물이 적게 배출되고 연료소비율도 가장 적게 나타났다. 쉘 앤 튜브는 판형과 핀 튜브 성능의 중간정도이다. 엔진에 미치는 영향으로만 판단할 때 핀 튜브 열교환기가 배기 열 회수에 가장 적합한 열교환기로 판단된다.