• 제목/요약/키워드: Fin height

검색결과 143건 처리시간 0.019초

삼각 핀의 해석과 고정된 핀 바닥 높이에 기준한 최적화 (Analysis and Optimization based on the Fixed Fin Base Height for a Triangular Fin)

  • 강형석
    • 신재생에너지
    • /
    • 제3권1호
    • /
    • pp.13-19
    • /
    • 2007
  • A triangular fin with variable fin base thickness and base height is analyzed and optimized for the fixed fin base height using a two-dimensional analytical method. At the middle of the fin length, the variation of the temperature along the fin height is listed. The influences of the fin length, base thickness and base height on the heat loss and fin efficiency are analyzed, The optimum heat loss, corresponding optimum efficiency and optimum fin length as a function of the fin base thickness are presented. The optimum heat loss and optimum fin tip length as a function of the convection characteristic number are represented.

  • PDF

고정된 핀 바닥 높이에 기준한 기하학적 비대칭 사다리꼴 핀의 최적 설계 (Optimum Design of a Geometrically Asymmetric Trapezoidal Fin Based on the Fixed Fin Base Height)

  • 강형석
    • 한국자동차공학회논문집
    • /
    • 제16권6호
    • /
    • pp.81-87
    • /
    • 2008
  • A geometrically asymmetric trapezoidal fin with variable fin base thickness and height is optimized based on the fixed fin base height using a one-dimensional analytic method. The temperature profile along the normalized X position in the fin is presented. For the fixed fin base height, the optimum heat loss, fin length and efficiency as a function of inside fluid convection characteristic number, fin base thickness and height, fin shape factor, convection characteristic numbers ratio and ambient convection characteristic number are represented. One of the results shows that the effect of fin base height and ambient convection characteristic number on the optimum values is remarkable.

대칭 사다리꼴 핀과 비대칭 사다리꼴 핀의 성능 비교 (Comparison of Performance between Symmetric Trapezoidal Fins and Asymmetric Trapezoidal Fins)

  • 강형석
    • 한국자동차공학회논문집
    • /
    • 제24권2호
    • /
    • pp.205-213
    • /
    • 2016
  • Heat loss and fin efficiency of symmetric and asymmetric trapezoidal fins with variable slope of fin's top surface are obtained by using a two-dimensional analytic method. Shapes of symmetric and asymmetric fins are changed from rectangular through trapezoidal to triangular by adjusting the fin shape factor. The ratio of symmetric trapezoidal fin length to asymmetric trapezoidal fin length is presented as a function of fin base height and convection characteristic number. The ratio of symmetric trapezoidal fin efficiency to asymmetric trapezoidal fin efficiency is presented as a function of the fin base height and fin shape factor. One of results shows that asymmetric trapezoidal fin length is shorter than symmetric trapezoidal fin length (i.e., asymmetric trapezoidal fin volume is smaller than symmetric trapezoidal fin volume) for the same heat loss when the fin base height and fin shape factor are the same.

지열시스템의 열교환기에서 원 관 내부 반경이 변하는 환형 핀의 최적화 (Optimization of an Annular Fin with Variable Pipe Inside Radius in the Heat Exchanger of Ground Source System)

  • 강형석
    • 신재생에너지
    • /
    • 제5권1호
    • /
    • pp.40-46
    • /
    • 2009
  • Optimization of a rectangular profile annular fin with variable pipe inside radius is presented. This optimum procedure is based on fixed fin height and is made by using variables separation method. The optimum heat loss, corresponding optimum fin length and optimum fin efficiency are presented as a function of pipe inside radius, fin half height, inside fluid convection characteristic number and ambient convection characteristic number. One of results shows that the optimum fin length increases linearly with increase of pipe inside radius for fixed fin height and fin base radius.

  • PDF

낮은핀관의 액막 증발 촉진에 관한 연구 (Enhancement of thin film evaporation on low-fin tubes)

  • 김내현
    • 설비공학논문집
    • /
    • 제10권6호
    • /
    • pp.674-682
    • /
    • 1998
  • In this study, thin film evaporation of water on low-fin tubes were experimentally investigated. Five low-fin tubes with different fin spacing and fin height were tested. Test range covered 0.146kg/ms $\leq$$\Gamma$$\leq$0.219kg/ms and 10㎾/$\m^2$$\leq$q $\leq$70㎾/$\m^2$. Saturation temperature was loot. Compared with the plain tube, low fin tubes enhanced the water film evaporation from 60% to 100%. Tubes with fin spacing smaller than 2mm and fin height higher than 1mm performed better than tubes with other fin configuration. However, when fin spacing was too small at high film flow or fin height was too high at low film flow, the performance decreased. The heat transfer coefficient slightly increased as the flow rate increased. Correlations are developed based on present data.

  • PDF

Comparative analysis of sectioned-body morphometric characteristics of diploid and triploid marine medaka, Oryzias dancena

  • Park, In-Seok
    • 환경생물
    • /
    • 제38권1호
    • /
    • pp.137-145
    • /
    • 2020
  • The sectioned-body morphometric characteristics of the diploid and triploid marine medaka, Oryzias dancena, of both sexes were examined to collect basic data on the significant differences between the diploid and triploid fish. Significant differences between the diploid and triploid fish in both sexes were observed in the body circumference anterior to the base of the pelvic fin, the body circumference anterior to the base of the anal fin, the body circumference anterior to the base of the dorsal fin, the area anterior to the base of the pelvic fin, the area anterior to the base of the anal fin, the area anterior to the base of the dorsal fin, the total height anterior to the base of the pelvic fin, the total height anterior to the base of the anal fin, the height anterior to the base of the pelvic fin, the height anterior to the base of the anal fin, the width anterior to the base of the anal fin, the belly thickness II anterior to the base of the anal fin, section shape 2-1, and section shape 4-1 (p<0.05). These measurements were greater in the triploid marine medaka of both sexes than those in the diploid marine medaka of both sexes, and they were also greater in the male diploid and triploid marine medaka than those in the corresponding female fish. Therefore, the sectioned-body morphometric dimensions were greater in the triploid males than those in the triploid females and the diploid fish in this study.

고정된 핀 바닥 높이에 기준한 비대칭 사다리꼴 핀의 최적화 (Optimization of an Asymmetric Trapezoidal Fin Based on the Fixed Fin Base Height)

  • 송년주;강형석
    • 한국추진공학회지
    • /
    • 제16권1호
    • /
    • pp.45-54
    • /
    • 2012
  • 위 측면 표면 기울기가 변화하는 비대칭 사다리꼴 핀의 최적화가 2차원 해석적 방법을 사용하여 수행된다. 고정된 핀 바닥 높이에 대하여 최적 열손실, 핀 길이 그리고 유용도가 내부유체 대류특성계수, 핀 바닥 두께, 핀 바닥 높이, 핀 형상계수 그리고 주위 대류특성계수의 함수로 나타내어진다. 이러한 최적화 절차를 위해서 핀으로부터의 최대 열손실 값의 95%를 최적 열손실 값으로 정의하였다. 결과 중 하나는 최적 열 손실과 유용도는 핀 형상계수의 변화에 독립적으로 보이는 반면 최적 핀 길이는 핀 형상계수가 증가함에 따라 거의 선형적으로 감소함을 보여주고 있다.

역 사다리꼴 핀의 최적화에 미치는 내 외 유체의 영향 (The Effect of Inside and Outside Fluids on the Optimization of a Reversed Trapezoidal Fin)

  • 강형석
    • 한국추진공학회지
    • /
    • 제11권5호
    • /
    • pp.14-22
    • /
    • 2007
  • 측면 표면 기울기가 변화하는 역 사다리꼴 핀이 2차원 해석적 방법을 사용하여 최적화된다. 핀 바닥 경계조건을 위해서, 내부유체로부터 내벽까지의 대류와 내벽부터 핀 바닥까지의 전도가 고려된다. 핀 끝 면으로부터의 열손실은 무시되지 않는다. 실제적인 핀 길이에서의 최대 열손실, 그 최대 열손실이 발생할 때의 최적의 효율, 핀 길이 그리고 핀 바닥 높이가 핀 내 외부의 대류특성계수의 함수로 나타내어진다. 결과 중 하나는 핀 바닥 높이에 대한 핀 끝 높이의 비가 커질수록 최적의 핀 형상은 두껍고 짧아지는 형상이 됨을 보여준다.

ANALYSIS OF A REVERSED TRAPEZOIDAL FIN USING A 2-D ANALYTIC METHOD

  • Kang, H.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제14권3호
    • /
    • pp.151-161
    • /
    • 2010
  • A reversed trapezoidal fin is analyzed using a two-dimensional analytical method. Heat loss from the reversed trapezoidal fin is presented as a function of the fin shape factor, fin base thickness and the fin base height. The relationship between the fin tip length and the convection characteristic number as well as that between the fin tip length and the fin base height for equal amounts of heat loss are analyzed. Also the relationship between the fin base thickness and the fin shape factor for equal amount of heat loss is presented. One of the results shows that the heat loss decreases linearly with the increase of the fin shape factor.

사각 핀의 절연된 핀 끝과 비 절연 핀 끝의 비교 (Comparison of Insulated Fin Tip and Non-insulated Fin Tip for a Rectangular Fin)

  • 강형석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2414-2419
    • /
    • 2007
  • A rectangular fin with variable fin height, fin length and surrounding temperature is analyzed using a one-dimensional analytical method. Both the heat loss from a rectangular fin with non-insulated fin tip and that with insulated fin tip are presented as a function of the fin height, fin tip length and the convection characteristic number. The relative error in the heat loss of these two cases is also given as a function of the same variables. One of the results shows that the trend of heat loss for both cases with the variation of given variables is similar even though the relative error increases as the shape of the fin becomes shorter and fatter.

  • PDF