• 제목/요약/키워드: Fin Pitch

검색결과 101건 처리시간 0.02초

광폭 루버 핀이 장착된 핀-관 열교환기의 공기측 전열 성능에 관한 실험적 연구 (An Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fin)

  • 김내현
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.254-262
    • /
    • 2015
  • Heat transfer rate can be increased by increasing the heat transfer area. In this study, wide louver fin-and-tube heat exchangers with $P_t/P_l=1.03$ were tested and compared with louver fin-and-tube heat exchanger with $P_t/P_l=0.6$. Results show that heat transfer capacities of wide louver samples are larger (9.8% at one row, 13.6% at two row and 4.1% at three row) than those of conventional louver samples. Considering the area ratio of 1.78, the increase of heat transfer capacity is rather small, possibly due to the smaller heat transfer coefficient and fin efficiency of the wide louver sample. The j factor of the louver fin was 67% larger at one row, 42% larger at two row and 52% larger at three row. The f factor of the louver fin was 81% larger at one row, 63% larger at two row and 60% larger at three row. The effect of fin pitch on j and f factors are not pronounced and the j factor decreased as the number of tube row increased.

Design Optimization of Pin-Fin Sharp to Enhance Heat Transfer

  • Li, Ping;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.185-190
    • /
    • 2005
  • This work presents a numerical procedure to optimize the elliptic-shaped pin fin arrays to enhance turbulent heat transfer. The response surface method is used as an optimization technique with Reynolds-averaged Navier Stokes analysis of flow and heat transfer. Shear stress transport (SST) turbulence model is used as a turbulence closure. Computational results for average heat transfer rate show a reasonable agreement with the experimental data. Four variables including major axis length, minor axis length, pitch and the pin fin length nondimensionalized by duct height are chosen as design variables. The objective function is defined as a linear combination of heat transfer and friction-loss related terms with weighting factor. D-optimal design is used to reduce the data points, and, with only 28 points, reliable response surface is obtained. Optimum shapes of the pin-fin arrays have been obtained in the range from 0.0 to 0.1 of weighting factor.

  • PDF

마이크로휜 표면과 발열체 기울기에 따른 PE5060의 비등 열전달에 관한 실험적 연구 (An Experimental Study on Boiling Heat Transfer of PF5060 on the Shape and Orientation of Micro-Fin Surfaces)

  • 김윤호;김충;이규정;김용찬
    • 대한기계학회논문집B
    • /
    • 제30권1호
    • /
    • pp.74-81
    • /
    • 2006
  • Experiments to measure the pool boiling heat transfer on the micro-fin surfaces were performed with PF5060. The effects of various orientation and subcooling of heat surface on pool boiling performance were investigated under various heat-flux conditions for plain and micro-fin surfaces. The comparison between the results of this study and those of previous work shows a similar trend at the same conditions. From the results, it is proved that nucleate boiling performance is strongly dependent on the orientation, the micro-fin structure and the subcooling of heat surface. The heat flux on the surface with orientation angles of $45^{\circ}$ and $90^{\circ}$ was larger than that on horizontal surface(${\theta}=0^{\circ}$) at same wall superheat because of the effect of bubble sweeping. The nucleate boiling performance of micro-fin surfaces is enhanced by decreasing the fin size(WxL) and the pitch, respectively. The subcooling makes nucleate boiling performance lower for both micro-fin and plain surfaces.

Optimal fin planting of splayed multiple cross-sectional pin fin heat sinks using a strength pareto evolutionary algorithm 2

  • Ramphueiphad, Sanchai;Bureerat, Sujin
    • Advances in Computational Design
    • /
    • 제6권1호
    • /
    • pp.31-42
    • /
    • 2021
  • This research aims to demonstrate the optimal geometrical design of splayed multiple cross-sectional pin fin heat sinks (SMCSPFHS), which are a type of side-inlet-side-outlet heat sink (SISOHS). The optimiser strength Pareto evolutionary algorithm2 (SPEA2)is employed to explore a set of Pareto optimalsolutions. Objective functions are the fan pumping power and junction temperature. Function evaluations can be accomplished using computational fluid dynamics(CFD) analysis. Design variablesinclude pin cross-sectional areas, the number of fins, fin pitch, thickness of heatsink base, inlet air speed, fin heights, and fin orientations with respect to the base. Design constraints are defined in such a way as to make a heat sink usable and easy to manufacture. The optimum results obtained from SPEA2 are compared with the straight pin fin design results obtained from hybrid population-based incremental learning and differential evolution (PBIL-DE), SPEA2, and an unrestricted population size evolutionary multiobjective optimisation algorithm (UPSEMOA). The results indicate that the splayed pin-fin design using SPEA2 issuperiorto those reported in the literature.

둥근 웨이브 핀-관 열교환기의 공기 측 전열 성능 (Airside Performance of Fin-and-Tube Heat Exchangers Having Round Wave Fins)

  • 김내현
    • 에너지공학
    • /
    • 제24권4호
    • /
    • pp.105-116
    • /
    • 2015
  • 본 연구에서는 절곡 깊이(1.4 mm)와 절곡 핏치(5.5 mm)가 같은 둥근 웨이브와 각진 웨이브 핀-관 열교환기에 대한 실험을 통하여 절곡 형상이 전열성능에 미치는 영향을 검토하였다. j 인자의 경우 둥근 웨이브 핀이 모든 열수에서 1.2~22% 크고 f 인자는 3열의 경우 8.3~23% 크고 1, 2열의 경우는 -1.0~29% 작다. 둥근 웨이브 핀이 우수한 성능을 보이는 이유로 둥근 웨이브 핀의 경우 각진 웨이브 핀 보다 유동이 핀의 곡면을 잘 따라갈 수 있으므로 골에 존재하는 재순환 영역의 크기가 줄어들기 때문으로 판단된다. 둥근 웨이브 핀의 경우 핀 핏치가 j와 f 인자에 미치는 영향은 크지 않다. 또한 j 인자는 튜브 열수가 증가할수록 감소하는 반면 f 인자는 튜브 열수와 무관하다. 실험 데이터로부터 새로운 상관식을 도출하였다.

나선형 핀튜브 열교환기의 열전달 특성에 관한 실험적 연구 (Experimental Study on the Heat Transfer Characteristics of Spiral Fin-Tube Heat Exchangers)

  • 윤린;김용찬;김슬우;최종민
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.529-535
    • /
    • 2005
  • This study experimentally examines the air-side performance of spiral finned tube heat exchangers. The effects of fin spacing, fin height, and tube alignment were investigated. Reduction of fin spacing decreased the Colburn j factor. However, the effect of fin height on the Colburn j factor was negligible. An increase of tube row decreased the Nusselt number for both staggered and in-line tube alignments. However, the decrease of the Nusselt number for the in-line tube alignment was much more significant than that of the staggered tube alignment. The average Nusselt number of the staggered tube alignment was larger than that of the in-line tube alignment by $10\%$ when the Reynolds number ranged from 300 to 1700. An empirical correlation of the Nusselt number was developed by using geometric parameters of heat exchanger and correction factors. The correction factor considered the effects of tube alignment and number of tube rows on the heat transfer. The proposed correlation yielded a mean deviation of $4\%$ from the present data.

핀-관 열교환기의 표면특성에 따른 착상 거동에 관한 연구 (A study on the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger)

  • 류수길;이관수
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.377-383
    • /
    • 1999
  • In this study, the behavior of frost formation according to surface characteristics in the fin-tube heat exchanger has been examined experimentally. The results show that the thickness of the frost which is attached to the hydrophilic heat exchanger becomes thin and the air pressure drop is smaller than that of bare aluminium heat exchanger However, the frost mass of hydrophilic heat exchanger is more than the bare one. Hence, high density frost is attached to hydrophilic heat exchanger. The sensible and latent heat flux of hydrophilic heat exchanger is bigger than that of bare one, but the increasing amount is very small and the improvement of thermal performance is also very small. The variation of fin-pitch of heat exchanger shows little influence on frost formation and hydrophilic heat exchanger loses its surface characteristics rapidly with increasing relative humidity.

  • PDF

설계조건에 따른 핀-튜브 증발기의 열전달 특성 (Heat Transfer Characteristics on Design Conditions of Finned-Tube Evaporators)

  • 강희정;이윤수;권영철;장근선;김영재
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.46-54
    • /
    • 2002
  • To investigate the design effects of a heat exchanger on a tube type, a tube circuit and a fin pitch, an experimental study on the heat transfer characteristics of finned- tube evaporators was performed. The refrigerant was R-22. A refrigerant loop was established to measure the heat transfer rate, the air heat transfer coefficient. The experimental results showed that the heat transfer characteristics of the evaporators were affected by the design parameters. And the heat transfer rate of the slit fin was better about 25%, compared to those of the louver fin. In the present experimental range, the heat transfer performance with the straight tube circuit was more remarkable than that of the zigzag tube circuit, as seen from temperature variations of the evaporator exit. $\jmath$-factor on the tube type, the tube circuit and the fin pinch decreased, as increasing Reynolds number.

Heat Transfer and Pressure Drop Characteristics of Plain Finned Heat Exchangers Having 5.0 mm Tubes

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Oh, Wang-Ku;Choi, Yong-Hwa;Gaku, Hayase
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권1호
    • /
    • pp.9-14
    • /
    • 2008
  • In this study, pressure drop and heat transfer characteristics of plain finned heat exchangers having 5.0 mm diameter (fin collar 5.3 mm) tubes were investigated. Six samples having different fin pitches (1.1 to 1.3 mm) and tube rows (1 and 2 row) were tested. The fin pitch had a negligible effect on j and f factors. Both j and f factors decreased as the number of tube row increased, although the difference was not significant for the f factor. When compared with the j and f factors of the samples having 7.3 mm diameter tubes, the present j and f factors yielded lower values. However, the j/f ratio was larger at low Reynolds numbers. Possible reasoning is provided from the flow pattern consideration. Comparison with existing correlations were made.

낮은 핀관의 형상이 LiBr 수용액의 풀 비등에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of Low Fin Tube Geometry on Pool Boiling of a LiBr Solution)

  • 김내현
    • 대한기계학회논문집B
    • /
    • 제39권7호
    • /
    • pp.591-598
    • /
    • 2015
  • 본 연구에서는 핀 핏치와 핀 높이가 다른 7종류의 낮은 핀관에 대하여 LiBr 농도 0%.~50%, 열유속 $20kW/m^2{\sim}40kW/m^2$, 포화압력 7.38kPa~101.3kPa에서 풀 비등 실험을 수행하였다. 실험 범위에서 최적 낮은 핀관 형상은 핀 핏치 26fpi, 핀 높이 1.8mm로 나타났다. 핀 핏치가 너무 넓으면 전열 면적이 감소하고 핀 핏치가 너무 좁으면 기포의 성장 및 이탈이 원활하지 못하게 되어 최적 핀 핏치가 존재한다. 포화압력이 낮아질수록, LiBr 농도가 증가할수록 열전달계수는 감소하였다. 이는 포화압력이 낮아질수록 기포의 이탈직경은 증가하고 이탈 빈도는 감소하기 때문이다. 또한 LiBr 농도가 증가하면 포화온도는 증가하고 물질확산율은 감소하는데 이에 따라 기포의 성장속도가 감소하고 따라서 열전달계수가 감소하게 된다. 낮은 핀관의 열전달계수는 모든 포화압력과 농도에서 평활관의 열전달계수보다 크게 나타났다. 본 실험자료를 기반으로 상관식을 제시하였다.