• Title/Summary/Keyword: Filtration pressure

Search Result 356, Processing Time 0.318 seconds

The Role of pd in the Unified Theory on Solid-Liquid Separation: Especially on the Cake Thickness at Hindered Sedimentation, Cake Filtration and Expression (고액분리 통합이론에서 pd의 역할: 간섭침전, 케이크 여과, 압착에서 케이크 두께를 중심으로)

  • Yim, Sung-Sam;Song, Yun-Min
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.334-342
    • /
    • 2012
  • To know the role of 'the solid compressive pressure to the first solid layer of a cake, $p_d$' in the 'unified theory on solid-liquid separation', we analyzed extremely compressible cake formed with floc for the following three operations with our new concepts. First, the role of $p_d$ was studied in calculating the sediment thickness of floc, and in calculating the cake thickness in cake filtration performed with floc sediment. Second, we calculated the expression procedure using $p_d$. Finally, the influence of $p_d$ on cake thickness in hindered sedimentation, and on the calculation of the procedure of hindered sedimentation $p_d$ was verified. Thus the possibility of application of 'unified theory on solid-liquid separation' and the importance of $p_d$ was verified. Through these processes, new theoretical definitions of the cake filtration, expression and hindered sedimentation was established.

A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter (정전형여과집진방식에서 여과특성에 관한 연구)

  • 천중국;박출재;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

Characteristic of the Permeation Flux of Hollow Fiber Membranes by Process Pressures Change (공정압 변화에 따른 중공사막의 투과플럭스 특성)

  • Lee, Yong-Taek;Kim, Nam-Su;Shin, Dong-Ho
    • Membrane Journal
    • /
    • v.17 no.4
    • /
    • pp.318-328
    • /
    • 2007
  • This study was carried out to evaluate the performance of the separate membrane (HF; hollow fiber membrane with polysulfone) process applied with the external membrane types, internal pressure membrane types and external-internal types according to the variations of pressure and membrane pore size in the purification treatment process of the lake water. The maximum permeate flux was average values of 282 LMH and 234 LMH with the pore size of 0.3 and 0.05 ${\mu}m$ respectively in the external pressure membrane process, and 443 LMH and 522 LMH with the pore size of 0.3 and $0.05{\mu}m$ respectively in the internal pressure membrane process. In addition, the maximum permeate flux of the process that was applied with external and internal membrane pressure simultaneously showed the average values of 674 LMH with the pore size of $0.3{\mu}m$, and 648 LMH with the pore size of $0.05{\mu}m$. Therefore, maximum yield per unit area is supposed when the separate membrane that was applied with external and internal pressure simultaneously are used to treat the lake water.

Effect of Pre-ozonation on the Trans-membrane Pressure of Ceramic Membrane (전오존이 세라믹 막의 차압에 미치는 영향)

  • Bae, Byung-Uk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.656-661
    • /
    • 2011
  • The performance of a domestic ceramic membrane with pore size of $0.1{\mu}m$ was evaluated to produce drinking water. A pilot-scale ceramic membrane filtration plant with a capacity of $1m^3/d$ was operated at the filtration flux of $3.0m^3/m^2{\cdot}d$ to investigate the effect of both backwash interval and pre-ozonation on TMP (trans-membrane pressure) increasing rate. The TMP increased with increasing the backwash interval. However, the application of pre-ozonation reduced the TMP increasing rate remarkably. When 1 mg/L of ozone was dosed with contact time of 5 min, TMP increasing rate at the backwash interval of 1 hr was reduced by 30%. This result indicated that pre-ozonation was very effective in reducing membrane fouling. There was almost no change in TMP increasing rate when the ozone contact time was maintained in the range of 5 to 15 min. Increasing ozone concentration up to 3 mg/L showed beneficial effect on TMP increasing rate.

Development and Basic Performance Characterization of Neutralized Fabric Filter (제전사여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 1998
  • A neutralized fabric filter of which major raw materials were polyester and stainless steel fibers was developed and its physiochemical properties and basic filter characteristics were investigated. Four finds of dusts generated in the typical domestic industry were used, which were coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, flu ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physicochemical properties of the neutralized fabric filter were analyzed in terms of changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres, mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, and pore size distribution. In addition, the pressure drop, dust penetration, and figure of merit for the fabric filter were investigated in a bench-scale filter testing unit. The pressure drop increased as the filtration velocity and dust loading increased, and its increasing shape depended on the type of dust. The dust penetration rapidly decreased as the dust loading increased irrespective of the type of dust. The figures of merit for the fabric filters increased in the early stage of filtration and then showed rapid decreases followed maintaining a constant level.

  • PDF

Ultrafiltration of oil-in-water emulsion: Analysis of fouling mechanism

  • Chakrabarty, B.;Ghoshal, A.K.;Purkait, M.K.
    • Membrane and Water Treatment
    • /
    • v.1 no.4
    • /
    • pp.297-316
    • /
    • 2010
  • Membrane fouling is one of the major operational concerns of membrane processes which results in loss of productivity. This paper investigates the ultrafiltration (UF) results of synthetic oil-in-water (o/w) emulsion using flat sheets of polysulfone (PSf) membrane synthesized with four different compositions. The aim is to identify the mechanisms responsible for the observed permeate flux reduction with time for different PSf membranes. The experiments were carried out at four transmembrane pressures i.e., 68.9 kPa, 103.4 kPa, 137.9 kPa and 172.4 kPa. Three initial oil concentrations i.e., 75 $mgL^{-1}$, 100 $mgL^{-1}$ and 200 $mgL^{-1}$ were considered. The resistance-in-series (RIS) model was applied to interpret the data and on that basis, the individual resistances were evaluated. The significances of these resistances were studied in relation to parameters, namely, transmembrane pressure and initial oil concentration. The total resistance to permeate flow is found to increase with increase in both transmembrane pressure and initial oil concentration while for higher oil concentration, resistance due to concentration polarization is found to be the prevailing resistance. The applicability of the constant pressure filtration models to the experimental data was also tested to explain the blocking process. The study shows that intermediate pore blocking is the dominant mechanism at the initial period of UF while in the later period, the fouling process is found to approach cake filtration like mechanism. However, the duration of pore blocking mechanism is different for different membranes depending on their morphological and permeation properties.

Performance Comparison of a Fabric Filter System with Centrifugal Force and a Conventional Fabric Filter System (원심력이 적용된 여과포집진장치와 기존 집진장치의 성능비교)

  • Kim Sang-Do;Park Young-Ok;Kang Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.739-748
    • /
    • 2004
  • A hybrid dust-collector combining a fabric filter with centrifugal force was developed to enhance the performance of the conventional fabric filter systems and its performances were evaluated to compare to that of the existing dust collector. The pressure drop rapidly increased with increasing the elapsed time and the face velocity in two filtration systems. But the increasing ratio of a hybrid dust-collector compare to the existing dust collector was lower. This results were confirmed from the performance such as cleaning interval, residual pressure drop and dust loading rate. The overall collection efficiency of the hybrid dust-collector was more than 99.6% and this showed a improvement of 0.6~2% than that of the existing dust collector. Especially, the fractional collection efficiency at the particle size of around 1${\mu}{\textrm}{m}$ is about 4% higher than that of the existing dust collector.

Development of a robust bench-scale testing unit for low-pressure membranes used in water treatment

  • Huang, Haiou;Schwab, Kellogg;Jacangelo, Joseph G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.121-136
    • /
    • 2011
  • A bench-scale test has recently been proposed as a predictive tool to minimize the scope of pilot-scale testing or to optimize the operation of full-scale membrane filtration systems. Consequently, a bench-scale testing unit was developed for this purpose and systematically evaluated in this study. This unit was capable of accommodating commercially available, low pressure, hollow fiber (LPHF) membranes with various configurations for testing under conditions comparable to real-world applications. Reproducibility of this unit in assessing membrane fouling and microbial removal efficiency of LPHF membranes was tested and statistically comparable results were obtained. This unit serves as a useful apparatus for academic researchers and utilities to evaluate the performance of LPHF membranes used for water treatment.

The Transient Response Characteristics of Compliant Coating to Pressure Fluctuations

  • Lee In-Won;Chun Ho-Hwan;Kim Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.533-544
    • /
    • 2006
  • The amplitude and phase lag of surface deformation were determined for a compliant coating under the action of turbulent pressure fluctuations. For this purpose, pressure fluctuations were measured experimentally. The amplitude and duration of coherent wave train of pressure fluctuations were investigated using digital filtration. The transient response was calculated for stabilization of forced oscillations of the coating in approximation of local deformation. The response of coating was analyzed with considerations of its inertial properties and limited duration of coherent harmonics action of pressure fluctuations. It is shown that a compliant coating interacts not with the whole spectrum of pressure fluctuations, but only with a frequency range near the first resonance. According to the analysis, with increasing elasticity modulus of the coating material E, deformation amplitude decreases as 1/E, and dimensionless velocity of the coating surface decreases as $1/\sqrt{E}$. For sufficiently hard coatings, deformation amplitude becomes smaller than the thickness of viscous sublayer, while surface velocity remains comparable to vertical velocity fluctuations of the flow.

CFD Analysis on Effect of Pressure Drop and Flow Uniformity with Geometry in 13" Asymmetric DPF (13" 비대칭 DPF 내 형상에 따른 배압 및 유동균일도 영향에 관한 전산해석연구)

  • HAN, DANBEE;BYUN, HYUNSEUNG;BAEK, YOUNGSOON
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.6
    • /
    • pp.614-621
    • /
    • 2020
  • Recently, as the fine dust is increased and the emission regulations of diesel engines are strengthened, interest in diesel soot filtration devices is rapidly increased. In particular, there is a demand for technology development for higher efficiency of diesel exhaust gas after-treatment devices. As part of this, many studies conducted to increase the exhaust gas treatment efficiency by improving the flow uniformity of the exhaust gas in the DPF and reducing the pressure drop between the inlet and outlet of disel particle filter (DPF). In this study, computational fluid dynamics (CFD) simulation was performed when exhaust gas flows into the canning reduction device equipped with a 13" asymmetric DPF in order to maintain the flow uniformity in the diesel exhaust system and reduce the pressure. In particular, a study was conducted to find the geometry with the smallest pressure drop and the highest flow uniformity by simulating the DPF I/O ratio, exhaust gas temperature, inlet-outlet pressure and flow uniformity according to the geometry and hole size of distributor.