• Title/Summary/Keyword: Filtration experiment

Search Result 202, Processing Time 0.019 seconds

A Study about Applicability of Treatment for Backwash Water Using Tubular Membrane System with Dead-End Operation Mode (역세 배출수 처리를 위한 관형막의 전량여과 운전 적용에 대한 연구)

  • Eom, Jung Yeol;Kim, Kwan Yeop;Kim, Young Hoon;Song, June Sup;Kim, Hyung Soo;Han, Myung Ae;Yang, Hyung Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.4
    • /
    • pp.437-444
    • /
    • 2008
  • Many other countries have investigated the new backwash water treatment process to save the existing water resource. There are various methods for reusing backwash water, but the membrane system has received the most interest for its efficiency. The objective of this study was to certify the application of membrane filtration system for the backwash water treatment. The experiment equipment was composed of Lab scale tubular membrane filtration system. Generally, cross-flow operation mode is used in the tubular membrane system but cross-flow operation mode demands high electric cost mainly for the pump energy. So to cut off electric cost, dead-end operation mode was used in this experiment. Filtration and bleed operation cycle was used in this membrane system. Backwash water was concentrated during the filtration process and when backwash water reached our target suspended solid concentration, it was discharged from this system. For efficient operation of filtration and bleed, mathematical matrix was drawn up and with this matrix we could simulate various sets of filtration and bleed time.

Rigorous Modeling of Single Channel DPF Filtration and Sensitivity Analysis of Important Model Parameters (단일 채널 DPF의 PM 포집 모델링 및 모델 파라미터의 민감도 해석)

  • Jung, Seung-Chai;Park, Jong-Sun;Yoon, Woong-Sup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.127-136
    • /
    • 2006
  • Prediction of diesel particulate filtration is typically made by virtue of modeling of particulate matter(PM) collection. The model is closed with filtration parameters reflecting all small scale phenomena associated with PM trapping, and these parameters are to be traced back by inversely analyzing large-scale empirical data-the pressure drop histories. Included are soot cake permeability, soot cake density, soot density in the porous filter wall, and percolation constant. In the present study, a series of single channel DPF experiment is conducted, pressure histories are inversely analyzed, and the essential filtration parameters are deducted by DPF filtration model formulated with non-linear description of soot cake regression. Sensitivity analyses of model parameters are also made. Results showed that filtration transients are significantly altered by the extent of percolation constant, and the soot density in the porous filter wall is controlling the filtration qualities in deep-bed filtration regime. In addition, effect of soot particle size on filtration quality is distinct in a period of soot cake regime.

Motion behavior research of liquid micro-particles filtration at various locations in a rotational flow field

  • Yan, Yan;Lin, Yuanzai;Cheng, Jie;Ni, Zhonghua
    • Structural Engineering and Mechanics
    • /
    • v.62 no.2
    • /
    • pp.163-170
    • /
    • 2017
  • This study presents a particle-wall filtration model for predicting the particle motion behavior in a typical rotational flow field-filtration in blower system of cooker hood. Based on computational fluid dynamics model, air flow and particles has been simulated by Lagrangian-particle/ Eulerian-gas approaches and get verified by experiment data from a manufacturer. Airflow volume, particle diameter and local structure, which are related to the particle filtration has been studied. Results indicates that: (1) there exists an optimal airflow volume of $1243m^3/h$ related to the most appropriate filtration rate; (2) Diameter of particle is the significant property related to the filtration rate. Big size particles can represent the filtration performance of blower; (3) More than 86% grease particles are caught by impeller blades firstly, and then splashed onto the corresponding location of worm box internal wall. These results would help to study the micro-particle motion behavior and evaluate the filtration rate and structure design of blower.

Effect of Buffer Composition, Sephadex Grade and Column Size on Filtration Based Quality Improvement of Semen from Murrah Buffalo Bull

  • Maurya, V.P.;Tuli, R.K.;Goyal, R.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.16 no.2
    • /
    • pp.165-171
    • /
    • 2003
  • Sixty semen ejaculates collected at weekly interval from four Murrah Buffalo bulls over a period of seven months (Nov.1999 to May 2000) were used in the present study. Three buffer medium (sodium citrate, TES and Tris) were used for soaking of sephadex. Three grades of sephadex (G-15,G-100, and G-200) were used for preparation of columns. Columns of three different height (one, two and three cm) were used for separation of semen. Twenty semen ejaculates were used in each project. In the first experiment each semen ejaculates was divided into four parts. One part was kept as control and other three parts were passed thought one cm column of sephadex G-15 prepared in three different buffers. There was significant (p<0.05) increase in percent progressive sperm motility and percent live spermatozoa and decrease in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome as well as sperm numbers after filtration through all the three columns. Sperm quality obtained in the filtrate of column prepared in Tris buffer was better in comparison to other two buffers. So the Tris buffer was used in the second trial. Twenty semen ejaculates were used in this experiment. Each semen ejaculate was divided into four parts. One part was kept as control (non-filtered) and other three parts were passed through columns of different grade of sephadex (G-15, G-100 and G-200). Progressive sperm motility and live sperm percentage improved significantly while decline in percent abnormal spermatozoa and percent spermatozoa with damaged acrosome and sperm concentration was observed after filtration through all the columns as compared to control (non-filtered) semen. Since post filtration quality of semen was better in the sephadex G-100 column, therefore it was selected for the next experiment. In third experiment, Tris buffer and sephadex G-100 were used for preparing columns of different height (one, two and three cm) and twenty semen ejaculates were filtered. The quality characteristics of semen (percent progressive sperm motility, percent live spermatozoa and sperm concentration) after filtration through one cm column were significantly (p<0.05) higher than after filtration through columns of two and three cm height. However non -significant (p>0.05) difference due to height of columns was observed for percent abnormal and percent damaged acrosome but 1 cm column comparatively gave better result than of 2 and 3 cm column height.

A Study on the Distribution of Hydraulic Head Along the Lateral in a Pilot-Scale Riverbank Filtration (강변여과에서 파일럿규모 수평집수관의 수두분포 연구)

  • Jeong, Jae-Min;Park, Jae-Young;Lee, Jong-Jin;Kim, Yong-Woon;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.334-339
    • /
    • 2013
  • A pilot-scale sand-box experiment simulating a lateral of collector well used in riverbank filtration was performed, and hydraulic head distributions along the lateral were measured according to the various drawdowns at the well. The results of this experiment were compared to the predicted values obtained using a theory previously developed by Kim in order for its validation. This theory predicts the head loss in a large-scale lateral given the loss in a small-scale one, and to have actual values for comparison, the results from a lab-scale experiment previously performed by Kim were employed. Comparing the experimental values to the extrapolated value indeed confirmed the validity of the theory. A procedure to determine the hydraulic head distribution of a practical-scale lateral was also presented applying the theory to the experimental result of this study in an effort to show the process of lateral design for riverbank filtration.

Study on the Theoretical and Experimental Application of Filtration-Permeation Method (여과-투과 방법의 이론적, 실험적 응용에 대한 연구)

  • Song, Yun-Min;Yim, Sung-Sam
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.161-167
    • /
    • 2008
  • Using an experimental method named filtration-permeation, the influence of sedimentation during filtration was studied for the suspensions composed of particles and that of flocs. The average specific cake resistances measured by filtration do not give accurate values because of the sedimentations during filtration, but the permeation data give quite accurate values. The prolonged permeation rates for the cake formed from particulate suspension do not change, but that rate from the floc filtration changes by the sweeping of flocculant. It is proposed that the cake compressibility can be measured with one set of filtration-permeation experiment by step increase of pressure during permeation period. The another experimental method which can shorten experimental time for floc filtration using filtrationpermeation is also proposed.

An Experimental Study on the Behavior of Phenol, 1,4-dioxane and Diazinon along the Travel Distance in Riverbank Filtration (강변여과에서 여과거리에 따른 페놀, 1,4-다이옥산 그리고 다이아지논의 거동에 관한 실험연구)

  • Choi, Hong-Gyu;Jeong, Il-Hwa;Jung, Kwan-Sue;Lee, Young-Deuk;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.436-441
    • /
    • 2013
  • An experiment using a 5 m-long sand column was performed to evaluate the resisting capability against micro-pollutants of the infiltration gallery, multi-purpose filtration pond and riverbank/bed filtration, of which the filtration distance is becoming increasingly shorter in Korea. Results suggested that the Korean riverbed sand contained significant amount of organics, resulting in a relatively vigorous adsorption of chloride ion on the sand surface. Results also indicated that while phenol was not detected in the column filtrate, both 1,4-dioxane and diazinon were exposed to adsorption by the sand as they moved through the column, decreasing their peak concentrations during the movement. It can be expected that the peak concentrations will diminish significantly in the practical scale due to its longer travel distance.

Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor (여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가)

  • Kim, Taeyoon;Lee, Junebae;Lee, Dongwoo;Shin, Hyunsuk;Kim, Hyunchul;Kwon, Soonchul
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.