Alum 주입 메쉬 침지 여과분리형 생물반응조의 운전 특성과 인 제거 (Phosphorus Removal and Operating Performance of Mesh Filtration Bio-reactor with the Addition of Alum)

  • 정용준;민경석
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.458-463
    • /
    • 2005
  • Considering the characteristics of a filtration bio-reactor equipped with a mesh filter module which can effectively maintain high concentration of biomass and enhanced solid-liquid separation performance, the hybrid process of filtration bio-reactor combined with coagulation was investigated to get improved filtration characteristics as well as water quality in this work. Two bio-reactors (Run-1 & Run-2) were operated under the following conditions: working volume of 25 L, continuous loading of a synthetic wastewater (BOD: 200 mg/L, T-N: 50 mg/L, T-P: 5 mg/L), where an appropriate amount of alum ($Al_2(SO_4)_3{\cdot}18H_2O$) was added once a day into the reactor (Run-2). In the system without using a alum (Run-1), the clogging of mesh filter module was observed two times through 85 days of whole operation. Meanwhile, the filter module did not clog even at higher MLSS concentration (6,000~12,000 mg/L) and the stable filtration (0.7 mid) was continued in the case of using a alum. Due to the stable formation of cake layers, BOD and SS were shown below 6 and 3 mg/L, respectively. T-P and pH of the effluent were changed because of the intermittent addition of the alum. In the case of Al/P=2.5, the average T-P removal efficiency per day was 85.2% and the average T-P concentration of the effluent was 0.3 mg/L. However, the removal efficiency of phosphate was influenced by pH in the reactor.

여과분리재를 이용한 슬러지 농축에 관한 연구 (Study on Sludge Thickening with Mesh is Used as Filtration Msdia)

  • 김부길;박민수
    • 한국환경과학회지
    • /
    • 제15권10호
    • /
    • pp.945-949
    • /
    • 2006
  • For a membrane bio-reactor, it is possible to fillet and separate activated sludge and effluent by head loss of centimeters, if non-woven fabric material is used as titration media. However, if non-woven fabric material is used to thicken high-concentration sludge, excessive sludge attachment causes the rapid decrease of flux. Mesh with fore sizes of $100{\mu}m,\;150{\mu}m,\;and\;200{\mu}m$ allows for easy separation of attached sludge. This study examined the possibility of mesh as filtration media. Existing close-flow filtration process, which requires maintaining sludge movement, makes It difficult to obtain high thickening rate. With a view of complementing this weakness, this study has made an experimental examination on how high-concentration sludge (about 3,000mg/L to 10,000mg/L) will be filtered and thickened when mesh module is submersed in the bio-reactor. Effluent flowed from the bottom of the bio-reactor by head loss of 65cm. In case of pore size of $100{\mu}m$, SS showed high recovery of 80% to 96%; therefore, it has been decided that mesh can be used as filtration media. Filtration lasted for more than 9 hours, until sludge with 9,000mg/L in MLSS concentration was thickened 9 times as dense. In the range from 3,610mg/L to 9,060mg/L in MLSS concentration, it was possible to obtain effluent with less than 2mg/L in MLSS concentration within 10 minutes.

Shadow mask 여과 모듈을 이용한 슬러지 농축 특성 (Sludge Thickening Performance of the Filtration Bio-reactor Equipped with Shadow Mask Filter Module)

  • 정용준;권구호;민경석
    • 한국물환경학회지
    • /
    • 제21권1호
    • /
    • pp.29-33
    • /
    • 2005
  • In order to recycle the waste material and to develop the thickening unit of waste activated sludge from wastewater treatment facilities, the filtration bio-reactor equipped with a shadow mask filter module was employed for this work from which the operating properties and parameters were drawn. The sludge thickening and filtration unit is made of cylindrical acryl tank(12cm i.d. ${\times}$ 58cm height: working volume of 6L), where the flat-sheet type of shadow mask filter module(pore size: 220~250um, opening area: 34.8~39.6%) was installed and the effluent was withdrawn from the effluent port at the lowest point of the reactor, and the filtration was performed only by the hydraulic pressure. For evaluating the operating performance of this reactor, some parameters such as the solid-liquid separation of different biomass concentrations, the water quality of filtrate, the aeration cleaning time and the cleaning effect were investigated. Depending on the MLSS concentrations, the different time to withdraw 3L of filtrate was required in which the longer filtration time was necessary for the higher MLSS concentrations caused by the thicker formation of cake layer: 40 minutes for 5,000 mg/L, 70 minutes for 10,000 mg/L and 100 minutes for 15,000 mg/L, where the concentrations of SS were 8.9, 6.7 and 6.5 mg/L, respectively. Under the same operating conditions (the intensity of aeration cleaning: 80 L/min, MLSS: 10,000 mg/L), the proper aeration cleaning time was revealed 30 seconds, and the stable formation of cake layer was in the range of 10 to 15 minutes. Therefore, the shadow mask considered as a waste material can be of use as a filter material for the sludge thickening system.

전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향 (Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge)

  • 홍성준;장인성
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) 공정은 막 오염을 해결하기 위해 막대한 에너지 소비를 하는 공정으로 알려져 있다. 이를 해결하기 위한 일환으로 전기응집 기술을 MBR에 적용하는 시도가 보고되고 있다. 본 연구에서는 전류밀도를 변화시켜가며 활성슬러지의 막 여과를 수행하여 전기응집이 막 오염 저감에 미치는 영향과 메커니즘을 파악하고자 하였다. 활성슬러지 혼합액을 전기응집한 후 회분식교반셀로 분리 막의 여과성능을 평가하였다. 전류밀도(A/m2)를 10에서 40으로 증가시켰을 때 총 오염 저항 (Rc+Rf) 값이 18%에서 79%까지 감소하여 전기응집으로 인해 분리 막의 여과성능이 향상됨을 확인할 수 있었다. 전기응집 전후로 유기물 농도와 활성슬러지 입도분포 변화는 거의 일어나지 않았다. 여과 성능의 향상은 수산화알루미늄, Al(OH)3이 생성되어 막 표면에 부착되면서 오염물질이 쌓이게 됨을 방지하는 역할, 즉 dynamic membrane 으로 작용하였기 때문인 것으로 판단되었다.

THE EFFECT OF AIR BUBBLES FROM DISSOLVED GASES ON THE MEMBRANE FOULING IN THE HOLLOW FIBER SUBMERGED MEMBRANE BIO-REACTOR (SMBR)

  • Jang, Nam-Jung;Yeo, Young-Hyun;Hwang, Moon-Hyun;Vigneswaran, Saravanamuthu;Cho, Jae-Weon;Kim, In S.
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.91-98
    • /
    • 2006
  • There is a possibility of the production of the air bubbles in membrane pores due to the reduction in pressure during membrane filtration. The effect of fine air bubbles from dissolved gases on microfiltration was investigated in the submerged membrane bio-reactor (SMBR). The $R_{air}$ (air bubble resistance) was defined as the filtration resistance due to the air bubbles formed from the gasification of dissolved gases. From the results of filtration tests using pure water with changes in the dissolved oxygen concentration, the air bubbles from dissolved gases were confirmed to act as a foulant and; thus, increase the filtration resistance. The standard pore blocking and cake filtration models, SPBM and CFM, respectively, were applied to investigate the mechanism of air bubble fouling on a hollow fiber membrane. However, the application of the SPBM and CFM were limited in explaining the mechanism due to the properties of air bubble. With a simple comparison of the different filtration resistances, the $R_{air}$ portion was below 1% of the total filtration resistance during sludge filtration. Therefore, the air bubbles from dissolved gases would only be a minor foulant in the SMBR. However, under the conditions of a high gasification rate from dissolved gases, the effect of air bubble fouling should be considered in microfiltration.

메쉬 침지여과분리형 회분식 생물반응조를 이용한 PEG제거의 기초 연구 (Fundamental Study on the Removal Properties of Polyethylene Glycols by Mesh Filtration Batch Bio-reactor)

  • 정용준
    • 한국물환경학회지
    • /
    • 제25권4호
    • /
    • pp.502-506
    • /
    • 2009
  • The removal properties of Polyethylene glycols (PEGs) known as the important group of synthetic polymers of ethylene oxide were examined by the bio-reactor equipped with a mesh filter module. PEG-1000 and PEG-2000 were fairly removed on the basis of TOC, which were 75.1% and 51.6%, respectively. In the case of PEG-20000, the removal efficiency of TOC was less than 15.2% and the favorable acclimation of microbes was not obtained. It was suggested that this system could effectively maintain microbes for the biodegradation of low molecular weight of PEG and TOC removal was significantly influenced by PEG molecular weight.

공기부상반응조에서 체류시간과 반송율에 의한 유기물질 및 질소제거 향상에 관한 연구 (Improvement of Organics and Nitrogen Removal by HRT and Recycling Rate in Air Lift Reactors)

  • 김진기;유성환;임봉수
    • 한국물환경학회지
    • /
    • 제22권1호
    • /
    • pp.45-50
    • /
    • 2006
  • This study was performed to evaluate the air lift reactors (ALR) by variations of HRT and recycling rate. Air lift reactor was composed of bioreactor and clarifier above it. To remove organic matters and nitrogen through the formation of microbic film and filtration, bio-filter reactors were filled with clay, glass, bead, waste plastic, respectively. Influent wastewater was fed to biofilter reactor, and effluent wastewater from bio-filter reactor was injected ALR again, instead of adding external carbon source. Effluent BOD concentration was satisfied with lower than 10 mg/L in recycling rate 100% regardless of the variation of HRT and the kinds of media materials. In HRT 4 hr, recycling rate 100%, BOD removal efficiency rate was from about 85 to 90%, COD removal efficiency rate was higher than 90%. Effluent TN concentration was satisfied with less than 20 mg/L, if HRT was maintained by over than 6 hr regardless of recycling rate and media materials. Over than HRT was 4 hr, microbes concentration in air lift reactor was maintained over than 2,500 mg/L constantly, not sensitive to environmental condition, and organic removal was effective as it was higher.

순산소 고율포기시스템 및 침지식 MBR융합공정에서 Biofouling 제어 및 원인물질 규명에 관한 연구 (The Study of Biofouling Control and Cause Material in Hybrid Process of Pure Oxygen and Submerged Membrane Bio-reactor)

  • 이상민;김미형
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.44-53
    • /
    • 2011
  • Membrane bio-reactor (MBR) has several advantages over the conventional activated sludge process, including a high biomass, low sludge production, and better permeate quality. Therefore, the MBR have gained popularity for municipal and industrial wastewater treatment. However the MBR usually were used for sewage and low streng th wastewater treatment because of membrane fouling problem and limitation of oxygen transfer into biomass. In this study, the hybrid process combining MBR and pure oxygen was tested for high strength organic wastewater treatment in the COD loading range from 2 to $10kgCOD/m^3{\cdot}day$. The hybrid process, membrane coupled pure oxygen high compact reactor (MPHCR), had been operated for one year and operation parameters, the effect of COD loading, MLSS concentration and the location of membrane module were studied for membrane fouling characteristic. Also membrane resistance test and the component of foulant was analyzed to investigate what is specific foulant in the MBR.

여과분리형 생물반응조의 고액분리 특성 (Solid-Liquid Separation Characteristics with Bio-filter Media Reactor)

  • 박영배;정용준
    • 한국습지학회지
    • /
    • 제16권3호
    • /
    • pp.347-353
    • /
    • 2014
  • 여과분리형 생물반응조 운전에서 발생하는 flux 감소 원인을 분석하였고, 상등수 수질과 침강성 변화가 flux에 미치는 영향을 평가하였다. 또한 여과막 모듈과 역세정 장치 일체형 시스템의 특성을 평가하였다. 반응조는 17L 유효 용적의 아크릴 반응조에 $100{\mu}m$ 공경의 여과막 모듈을 통해 배출되는 여과시스템으로, 여과시간이 경과함에 따라 상등수의 수질 특히 탁도와 TOC의 수질이 악화됨에 따라 flux가 점진적으로 감소하였다. MLSS 농도가 18000mg/L 이상에서는 여과저항이 급격히 증가하였다. 상등수의 수질과 flux와의 관계를 규명하기 위해서는 MLSS 농도가 10000mg/L 이상에서는 곤란함에 따라 5000mg/L이 적절한 것으로 판단된다. 활성슬러지 플록을 파괴시켜 SVI를 250으로 조정하여 여과를 시작한 경우, 상등수의 탁도가 증가하여, 침강성이 악화됨에 따라 flux도 점차 감소하였다. 여과막 모듈과 폭기세정 장치를 일체화한 시스템에서 공기 공급은 30~60초 정도로 설정함이 적정한 것으로 나타났다.

막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석 (Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction)

  • 김경래;김완규;장인성
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.