• Title/Summary/Keyword: Filter bag

Search Result 162, Processing Time 0.048 seconds

Filtration Characteristics of Paticulate Matter at Bag Filters Coated with PTFE Membrane During Off-Line Pulsing (PTFE membrane이 코팅된 여과백의 off-line 탈진시 미세먼지 집진 특성)

  • Kim, Joung-Hun;Moon, Il-Shik;Hwang, Min-Young;Kim, Ryang-Gyoon;Ko, Daekwun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.7
    • /
    • pp.391-402
    • /
    • 2017
  • Particulate matter becomes an important issue in the environmental society recently so that it is necessary to evaluate that the commercial application of baghouse systems for effective control of fine particulates is viable. A laboratory-scale baghouse experimental apparatus with filter bags made of PTFE felt or PTFE felt coated with PTFE membrane is used to investigate the filtration performances of fine particulates. Experiments by changing filtration velocity, inlet dust concentration, and average dust particle size show that the dust collection efficiency becomes higher at lower filtration velocity, higher inlet dust concentration and larger average dust particle size. The total pressure drop through the filter media and dust layer becomes higher at higher filtration velocity and higher inlet dust concentration. The dust collection efficiency is higher and the pressure drop is lower at a baghouse with filter bags coated with PTFE membrane than that without membrane coating. From the result that the dust collection efficiency of $PM_{2.5}$ in a reasonable filtration velocity range during off-line pulsing at a baghouse with PTFE felt bag filters coated with PTFE membrane is as high as 99.99%, it is confirmed that the use of baghouse is an effective measure to control the fine particulates.

Effect of a pathogenic bacteria filtration instrument for infection prevention during mouth-to-mouth ventilation (입-입 인공호흡(Mouth-to-mouth ventilation)을 위한 감염방지 도구의 병원성 세균 여과 효과)

  • Shim, Gyu-Sik;Kim, Eun-Mee
    • The Korean Journal of Emergency Medical Services
    • /
    • v.20 no.3
    • /
    • pp.49-56
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of a pathogenic bacteria filtration instrument for infection prevention during mouth-to-mouth ventilation. Methods: Two kinds of face shields were used for the study. One rescuer blew the filter through a bag valve mask and the filter was then cultured for bacteria. The mask was tested both on the front and back side. Results: Two kinds of face shields including the KF shield and CM shield were tested. The KF shield has received national certification and it prevented transmission of bacterial infection but the CM shield showed the opposite result and did not prevent bacterial transmission. Pathogenic bacteria were found on the back of the CM shield. Conclusion: A certified face shield is very important to prevent bacterial transmission. Face shields should be demonstrated and used by paramedic students.

Characteristics of Large-area PTFE Filter Coated with PTFE Nanofiber Fabricated by Roll-to-roll Equipment (Roll-to-roll 공정으로 제조한 나노섬유가 코팅된 대면적 PTFE 필터 특성)

  • Ahn, Seunghwan;Lee, Woo Jin;Kim, Yeonsang;Shim, Euijin;Eom, Hyeonjin
    • Applied Chemistry for Engineering
    • /
    • v.33 no.6
    • /
    • pp.613-617
    • /
    • 2022
  • The equipment for fabricating the large-area PTFE nanofiber coated-PTFE foam filter for use as filtration parts of the baghouse that removes particulate matter (PM) in industrial sites was designed and manufactured in this study. The PTFE nanofiber was coated on a commercial PTFE foam filter to increase its PM collection efficiency. The equipment and fabrication processes using a roll-to-roll system were proposed to continuously coat PTFE nanofibers on the surface of the PTFE foam filter. The electrospinning and annealing parts were designed and made by optimizing the equipment for the roll-to-roll system. The surface morphology, composition, and filtration characteristics of the large-area filter fabricated by this equipment were confirmed. PTFE nanofibers were uniformly coated on the large-area filter, and the PTFE nanofiber coated-PTFE foam filter showed PM2.5 collection efficiency of 91.79% and an appropriate pressure drop of 62 Pa with a face velocity of 1 m/min at 280 ℃.

A Study on the Pyrolysis and Combustion Characteristics of Solid Waste in a Pilot scale Pyrolysis Melting Incinerator (Pilot 규모의 열분해 용융 소각 시스템에서의 열분해 및 연소 특성 연구)

  • Yu, Tae-U;Yang, Won;Park, Ju-Won;Kim, Bong-Keun;Lee, Gi-Bang;Kim, Hi-Yeol;Park, Sang-Shin;Jeon, Keum-Ha
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.168-174
    • /
    • 2006
  • A pilot scale (200kg/hr) pyrolysis melting incineration system is designed and constructed in Korea Institute of Industrial Technology. The incineration process is composed of pyrolysis, gas combustion, ash melting, gas stabilization, waste heating boiler, and bag filter. For each unit process, experimental approaches have been conducted to find optimal design and operating conditions. Especially, a pyrolysis is very important process in that it is a way of energy recirculation and minimizing the waste products. This paper presents major results of the most efficient operating conditions in a pilot scale pyrolysis melting incinerator.

  • PDF

A Study on the Correlation Level Among Air Pollution from Solid waste Incinerator (고형폐기물 소각로에서 배출되는 대기오염물질간의 상관성에 관한 연구)

  • 조상원
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.183-187
    • /
    • 1999
  • The purpose of this study is providing basic data to control the air pollutants from solid waste incinerator. Incinerating the waste wood, the electrostatic precipitator had the best collection efficiency. The leather incineration had the same collection efficiency as synthetic resin incineration. And the coarse particle collection efficiency was high. As you know in correlation of leather incineration. pollutants produced a from incinerator are mostly fine particles. If the scrubber used only in the process produced a lot of fine particles. It is adequate to use the above control devices, together with high efficiency collector like bag-filter. To select the adequate control devices, it is required to investigate the size distribution before establishing control devices.

  • PDF

A Study on Control of Dusts in Work Environment (유해 분진사업장의 분진제어에 관한 연구)

  • 김영식;오광중
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.2
    • /
    • pp.1-6
    • /
    • 1995
  • Authors investigated the size distribution and mass fraction of dusts in work environment of Changwon industrial complex. Size distribution of suspended dusts in welding and grinding processes were evaluated using ambient cascade impactors. The mass median diameters of dusts were 0.25 to $0.60 \mu m$ at welding sites and 1.20 to $1.92 \mu m$ at grinding sites. Respirable mass fractions were 63.68 to 73.50% at welding sites and 43.24 to 51.47% at grinding sites. Respirable fractions were calculated from the size distribution data for the ACGIH criteria by the respirable particle mass. In case of dust removal system, electrostatic precipitator and bag filter were appropriate for welding process and grinding process, respectively.

  • PDF

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF

A Study on Toluene Removal of VOC and Characteristics of Material Using Biofilter (Bio필터를 이용한 VOC 가스 중 Toluene 제거율과 필터특성 연구)

  • 강신묵;하상안
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.88-94
    • /
    • 1998
  • This study was investigated the application of biofiltration using cometabolic process to remediate gaseous toluene that are highly recalcitrant to adsorption, absorption and biodegradation. The investigation was conducted using specially built steel columns packed with granular activated carbon for removal of toluene and G.A.C was also coated with Pseudomonas putida microorganisms by addition of KH$_{2}$PO$_{4}$. The biofilter unit was operated in the condition of dry and 27.5% moisture content at gas loading rate of 12.5 l/min. Gaseous toluene taken from tedlar bag was analyzed by the use of G.C. equipped with F.I.D. detector. The removal efficiency of gaseous toluene was 85% at average inlet concentration of 970 ppm during dry operating condition. For gaseous toluene, 91% removal efficient was obtained at the filter material with moisture content and 97% removal efficiency was obtained with Pseudomonas putida microorganisms at gas loading rate of 12.5 l/min.

  • PDF

A method of vibration reduction for "Godet Roller" in the spinning system (방사설비 시스템 중 "Godet Roller 부"에 대한 진동저감 방법)

  • Park, Young-Su;Park, Se-Hong;Kim, Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.82-87
    • /
    • 2012
  • Research and development of the spinning system which become bigger, faster and more detailed has been making progress continuously due to the increasing use of yarn which is considered as raw material to make industrial goods such as tire cord, air bag, filter, seatbelt and fiber-optic cable along with a remarkable growth of industry. In this paper, the desirable procedure and design requirements concerning a method of vibration reduction for "Godet Roller" considered as the main source of high vibration in the spinning system were suggested, and then verified those by analysis and actual test.

  • PDF

Operation and Performance of Industrial Bag Filter Apparatus (산업용 여과포집진장치의 운전 및 성능)

  • 박영옥
    • Membrane Journal
    • /
    • v.5 no.1
    • /
    • pp.16-25
    • /
    • 1995
  • 먼지는 일반적으로 입자크기가 $10\mu\textrm{m}$ 이상의 강하 먼지와 $10\mu\textrm{m}$ 이하의 부유먼지로 구분하며, 이들의 먼지는 대기중에서 인간이나 동.식물에 주로 영향을 준다. 입자크기 범위가 $0.1~10\mu\textrm{m}$ 사이의 부유먼지는 주로 산업공정에서 연료의 연소 또는 고체상 물질의 분쇄 및 수송공정 등에서 주로 발생되며, 입자크기가 $2.5\mu\textrm{m}$이하인 것들은 대기중에서 황산화성 미세먼지와 질산화성 미세먼지로 전환되어 가시도(visibility)에도 큰 영향을 미친다. 대기중에 부유된 먼지중에서 $8\mu\textrm{m}$ 이하는 호흡시 호흡기로 유입되는 입자크기로써, 입자크기가 $6.0\mu\textrm{m}$ 이하인 것은 약 10% 정도가 인간의 폐내로 유입되고, $4.0\mu\textrm{m}$ 이하인 것은 30%, $2.0\mu\textrm{m}$ 이하인 것은 약 99%가 폐(lung)에 유입되어 폐에 침착된다고 보고하였다. 앞으로 산업발전이 계속됨에 따라서 먼지의 배출량이 계속 증가할 것이며, 이로 인해 먼지에 의한 대기오염이 심각해질 뿐만 아니라 인간에 미치는 피해도 심각해질 것으로 예측된다.

  • PDF