• Title/Summary/Keyword: Filter Quality

Search Result 1,537, Processing Time 0.031 seconds

Power Quality Disturbances Detection Technique using Filter Bank and Adaptive Filters (필터뱅크와 적응필터를 이용한 전력품질 외란 검출기법)

  • Yun, Jae-Jun;Lee, Jeong-Kyu;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.162-167
    • /
    • 2012
  • In power quality monitoring, it is very important to detect disturbances (sag, swell, transient, and interruption) accurately. In this paper, a detection method for power quality disturbances by combining the filter bank system and adaptive filter is proposed. To decompose power signal, binary tree structured filter bank system is designed. In the filter bank system, the fundamental filter bank(QMF bank) is used as a module in each decomposing level. An adaptive filter is used to improve the detection accuracy of disturbances for each subband signal. In the adaptive filter, the measure of estimated error change is used to detect singular points of power quality disturbances. Computer simulations were performed on synthetic signals which have disturbances to assess the performance of the proposed method.

A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters (단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

Median modified wiener filter for improving the image quality of gamma camera images

  • Park, Chan Rok;Kang, Seong-Hyeon;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2328-2333
    • /
    • 2020
  • The filter technique was applied to noise images, as noise is the significant factor that cause poor image quality due to lower photon counting. The purpose of this study is to confirm that image quality can be improved using the median modified Wiener filter (MMWF) technique; this is achieved via a National Electrical Manufacturers Association International Electrotechnical Commission body phantom with four large spheres that are filled with the 99mTc radioisotope when evaluating the image quality. Conventional filters such as Wiener, Gaussian, and median filters were designed, and signal to noise ratio, coefficient of variation, and contrast to noise ratio were used as the evaluation parameters. The improvement in the image quality was in the following order, from the least to the highest improvement, in all cases: Wiener filter, Gaussian filter, median filter, and the MMWF technique. The results show that the image quality was improved from 20.6 to 65.5%, 7.4-40.3%, and 12.7-44.7% for the SNR, COV, and CNR values, respectively, when using the MMWF technique, compared with the use of conventional filters. In conclusion, our results demonstrated that the MMWF technique is useful for reducing the noise distribution in gamma camera images.

Performance of Respirator Filters Using Quality Factor (qF) (양질계수(Quality Factor)를 이용한 방진마스크 필터의 성능평가)

  • Han, Don-Hee;Jeong, Yoon-Sok
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.170-178
    • /
    • 2000
  • Most of manufacturers try to produce the most efficient filter for respirators with the lowest breathing resistance. Filter performance depends on low penetration, i.e., high efficiency (%), and low pressure drop ($mmH_2O$). This study was performed to evaluate performance of respirator filters by quality factor ($q_F$) and suggest the direction for improvement of respirator filters of good quality in Korea. Two mechanical filters, S and K made in Korea, three filtering facepieces, S made in China, C made in Korea and M made in USA, which were widely used in the workplace, were selected and tested efficiency and pressure drop in accordance with flow rate, using with Automated Filter Tester Model 8110 (TSI, USA). The best quality factor within the same respirator filter categories was $0.0672cm^{-1}\;H_2O$ for mechanical filter S, $0.0698cm^{-1}\;H_2O$ for filtering facepiece M at flow rate of 32Lpm. Mechanical filter S would be the best suitable during heavy work since qulity factors decrease less sharply than any others as increased flow rates. It was necessary for mechanical filter S to lower pressure drop without increasing efficiency, but mechanical filter K should be increased efficiency and decreased pressure drop. While filtering facepiece M had the best quality performance of three ones, Sand C should get much higher efficiency and lower pressure for better performance.

  • PDF

The development of Air-cleaner with Roll Filter inside railroad passenger car (롤필터를 장착한 객차용공기청정장치 개발)

  • Lee, Young-Seop;NamGoong, Seok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1297-1301
    • /
    • 2007
  • The indoor air quality guideline of public transportation means was prepared recently. therefore we consider a countermeasure for the indoor air quality improvement of public transportation means. In this work, air-cleaner with roll filter system which developed alternative of indoor air quality guideline. The develpoed roll filter system is two function. the first function harmoniously circulated to heating and cooling air through HVAC system and secondary function removed PM(particluatie matters) which re-scatting to passenger's movement and suppled from outdoor air. Filter media of roll filter system select optimum electret mesh filter out of many filter media. Selected filter media was performanced tests of pressure drop, collection efficiency and dust holding capacity. Finally developed roll filter system was performanced bench test.

  • PDF

An Optimal Method to Improve the Visual Quality of Medical Images

  • Shin, Choong-ho;Jung, Chai-yeoung
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.141-144
    • /
    • 2015
  • As the visual quality of X-ray images is a critical reference for the accuracy of the clinical diagnosis, the methods to improve the quality of X-ray images have been investigated. Among many existing methods, using frequency domain filter is a very powerful method to improve the visual quality of images. In this paper, the inherent noises of the input images are suppressed by adding the Laplacian image to the subjected image. The medical X-ray images using the optimal high pass filter has shown improved edges. Further, the optimal high frequency emphasis filter has shown the improved contrast of flat areas by using the result image from the optimal high pass filter. Also the resulting images of the global contrast have improved by the histogram equalization. As a result, the proposed methods have shown enhanced contrast and edges of the images with noise canceling effect.

A Basic Study on the Development of the Single-Phase Unified Poorer Quality Conditioner (단상용 통합형 전력품질 개선장치의 개발에 관한 기초연구)

  • 노대석;이현옥;오성철;최재석;차준민;김재언
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.2
    • /
    • pp.90-98
    • /
    • 2003
  • Recently, the increasing application of electronic equipments and information devices has heightened the interest in power qualify. The term power quality is applied to a wide range of electromagnetic phenomena on the power system and is also concentrated by all areas such as utilities, their customers and suppliers of load equipments. In engineering terms, power Qualify is expressed by voltage qualify because the power supply system can only control the quality of the voltage. Therefore, the standards in power quality area are devoted to keep the supply voltage within allowable limits. This paper deals with single-phase unified power quality conditioner (UPQC), which ai s at the integration of series-active and shunt-active filter. The series filter il used to compensate for the voltage distortions and the shunt filter is used to provide reactive power and counteract the harmonic current injected by the load. Also, the voltage of the DC link capacitor is controlled to a desired value by the shunt active filter. The validity of the proposed UPQC is demonstrated using both the MATLAB/SIMULINK simulation and the experimental device with DSP (TMS320C32).

A study on the standardization of Noise Filter drawings (노이즈 필터 도면 표준화 방안에 관한 연구)

  • Lee, JiHyeog
    • Journal of Korean Society for Quality Management
    • /
    • v.46 no.3
    • /
    • pp.379-396
    • /
    • 2018
  • Purpose: The purpose of this study was to propose a standard form of noise filter drawing, which is widely used in the field of weapon systems, to define the essential specification which is not standardized at the existing drawings and to employ the reference for manufacturing and qualification test. Methods: To do that, it identifies the improvements to analyze 19 noise filter drawings, studies the principle of noise filtering to find the essential part of the spec. and reviews the MIL-STD-220C and KS IEC 60939, which is the widely used as a formal spec. pertaining to the noise filter. Throughout the study, a standard form is developed to standardize the attenuation characteristics and find eight crucial metrics to specify the noise filter. Results: The results of this study are as follows; The standardized drawings can be used as the qualification test of the item and the manufacturing and engineering documents to make the noise filter, which are also applicable to the reference document to review KDS(Korea Defense Standard) drawings.

Evaluation of the Relationship between Filter Replacement and Filter Performance Change in Particulate Respirators (방진 마스크 필터 교체와 성능 변화의 상관성 조사)

  • Lee, Heonyung;Park, Jihoon;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.283-290
    • /
    • 2017
  • Objectives: This study aimed to evaluate the relationship between filter replacement and filter performance change in particulate filters used in the workplace. Methods: Three types of particulate respirator filters are mainly used in the workplaces. These were tested against the filter performance safety certification standard for dust masks established by the Ministry of Employment and Labor(MoEL). Used filters were collected to test their performance, such as filter pressure drop, efficiency, and quality factors. All these factors were evaluated by a filter tester. To compare filter performance between used and new ones, the same kinds of new filters were also tested together under the same procedures. Results: A total of 270 used filters were collected for testing. The main reasons to replace the filters were difficulty in breathing(46.2%), dirty/odor influx(19.7%), and a combination of factors(26.7%). The pressure drop for two special class groups was significantly different(new filters: $20.72{\pm}3.33mmH_2O$; used filters: $24.70{\pm}5.26mmH_2O$, p<0.0001). In the case of penetration, new filter groups indicated $0.0032{\pm}0.0040%$, while that of the used filters was $0.0596{\pm}0.1187%$. The quality factor for the used filters($0.34{\pm}0.09$) significantly decreased compared to the new filters($0.53{\pm}0.08$) (p<0.0001). Conclusions: Filter performance including pressure drop, penetration, and the quality factor was evaluated and compared between new and used filters in the workplace. The results showed that general filter performance deteriorated more for change of pressure drop, penetration and the quality factor.