• Title/Summary/Keyword: Filter Media

Search Result 795, Processing Time 0.026 seconds

Test Method for Particle Removal Characteristic of Equipment Fan Filter Unit (EFFU) (Equipment Fan Filter Unit (EFFU)의 Particle 제거 성능평가 방법)

  • Lee, Yang-Woo;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.59-62
    • /
    • 2012
  • This test method covers a procedure for measuring particle removal characteristic of equipment fan filter unit(EFFU) installed inside of semiconductor process equipments, FPD manufacturing equipments and so on. Since EFFU is a combination of air filter and the assembly of fan, motor and frame, the integrity of these parts is very important for the performance of EFFU. So a conventional particle removal test method for air filters is not suitable for EFFU particle removal performance. This test method defines an evaluation method for EFFU which is installed inside an enclosed space to remove particles that are generated inside process equipment. The particle removal performance of EFFUs is usually depending on the performance of filter media and air flow rate. To understand a performance of an EFFU, the filter media characteristic, air flow rate and the integrity of EFFU parts should be considered simultaneously. This test method is intended to demonstrate the system performance of an EFFU and successfully evaluated EFFU performance characteristics.

CenterTrack-EKF: Improved Multi Object Tracking with Extended Kalman Filter (CenterTrack-EKF: 확장된 칼만 필터를 이용한 개선된 다중 객체 추적)

  • Hyun-Sung Yang;Chun-Bo Sim;Se-Hoon Jung
    • Smart Media Journal
    • /
    • v.13 no.5
    • /
    • pp.9-18
    • /
    • 2024
  • Multi-Object trajectory modeling is a major challenge in MOT. CenterTrack tried to solve this problem with a Heatmap-based method that tracks the object center position. However, it showed limited performance when tracking objects with complex movements and nonlinearities. Considering the degradation factor of CenterTrack as the dynamic movement of pedestrians, we integrated the EKF into CenterTrack. To demonstrate the superiority of our proposed method, we applied the existing KF and UKF to CenterTrack and compared and evaluated it on various datasets. The experimental results confirmed that when EKF was integrated into CenterTrack, it achieved 73.7% MOTA, making it the most suitable filter for CenterTrack.

Cabin Air Filter Media Produced by Needle Punching Process (니들펀치 공정에 의한 캐빈에어필터 여재의 제조)

  • Park, Seungkyu;Kim, Heonchang
    • Applied Chemistry for Engineering
    • /
    • v.20 no.5
    • /
    • pp.561-564
    • /
    • 2009
  • Filter media finely interspersed with activated carbons were prepared by a needle punching process without using chemical binders. Their characteristics were investigated efficiently to abate environmentally harmful gas such as acetaldehyde, and were compared with those of cabin air filter coated with activated carbons by using chemical binders. These combination filters were installed on a vehicle fan placed in a test chamber of capacity similar to the interior volume of a commercially available passenger car, and the efficiency of acetaldehyde abatement was measured as a function of time. The filter utilizing chemical binders showed somewhat better performance for the elimination of acetaldehyde despite the adverse effect of the chemical binder that would clog the micropores of the activated carbons. It turned out that the needle punching process had the activated carbons agglomerated due to hydrophobic interactions, resulting in a relatively larger void area than that of the filter utilizing chemical binders.

A Novel High Rate Flocculator/Filter in Water and Wastewater Treatment (상하수처리를 위한 새로운 고효율 응집/여과 장치)

  • Vigneswaran, S.;Ngo, H.H.;Kwon, Dae-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2005
  • Conventionally used flocculation tanks require large space and high energy requirement for mixing. Static flocculators using gravel bed filter operate at a lower flow rate ($5-10m^3/m^2{\cdot}h$). Further, the cleaning of this system is difficult. A novel high rate static flocculator/filter developed at UTS packed with buoyant media such as polystyrene, polypropylene has been found to operate at higher filtration rates (30-45 $5-10m^3/m^2{\cdot}h$). They can easily be cleaned with minimal energy. Detailed experiments conducted with an artificial kaolin clay solution show that buoyant media is an excellent static flocculator in producing uniform filterable microflocs (12-15 m) even when it is operated at a high rate of 30-40 m/h. Detailed filtration experiments were conducted in a wastewater treatment plant to treat the biologically treated effluent with a floating media of depth of 120 cm. This filter was able to remove majority of phosphorus and remaining solids. It reduced significantly the fecal coliforms and fecal streptoccoci, thus requiring less amount of chlorine for disinfection. The advantage of this system is the low energy and water requirement for cleaning of filter bed. The periodic backwash adopted 30 seconds air and water and 30 seconds water cleaning every 90 minutes filter operation. Thisis equivalent to 1-2% of filtered water production. Mechanical cleaning system on the other hand, requires very low energy requirement (<1% of filtered water production).

Adaptive In-loop Filter Method for High-efficiency Video Coding (고효율 비디오 부호화를 위한 적응적 인-루프 필터 방법)

  • Jung, Kwang-Su;Nam, Jung-Hak;Lim, Woong;Jo, Hyun-Ho;Sim, Dong-Gyu;Choi, Byeong-Doo;Cho, Dae-Sung
    • Journal of Broadcast Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-13
    • /
    • 2011
  • In this paper, we propose an adaptive in-loop filter to improve the coding efficiency. Recently, there are post-filter hint SEI and block-based adaptive filter control (BAFC) methods based on the Wiener filter which can minimize the mean square error between the input image and the decoded image in video coding standards. However, since the post-filter hint SEI is applied only to the output image, it cannot reduce the prediction errors of the subsequent frames. Because BAFC is also conducted with a deblocking filter, independently, it has a problem of high computational complexity on the encoder and decoder sides. In this paper, we propose the low-complexity adaptive in-loop filter (LCALF) which has lower computational complexity by using H.264/AVC deblocking filter, adaptively, as well as shows better performance than the conventional method. In the experimental results, the computational complexity of the proposed method is reduced about 22% than the conventional method. Furthermore, the coding efficiency of the proposed method is about 1% better than the BAFC.

Implementation of Filter Bank-Based RF Transceiver for TV White Space

  • Kang, Kyu-Min;Park, Jae Cheol;Park, Seungkeun
    • ETRI Journal
    • /
    • v.37 no.6
    • /
    • pp.1077-1086
    • /
    • 2015
  • This paper presents a general-purpose design scheme of a filter bank (FB)-based radio frequency (RF) transceiver that operates across the entire ultra-high frequency (UHF) TV band from 470 MHz to 698 MHz and complies with the TV white space (TVWS) regulatory requirements. To this end, an intermediate frequency (IF) band-pass filter (BPF) with a sharp skirt characteristic is considered as a solution for handling the incoming signals from a baseband modem. Specifically, an FB-based BPF structure with four ceramic resonator filters that effectively rejects unwanted signals is proposed to extract a desired signal in the TV band. Achievable data rates of a cognitive radio system (CRS) employing the proposed FB-based RF transceiver at the application layer are investigated in both wired and wireless environments. The service coverage of the CRS network is measured according to several modulation and coding schemes (MCSs) of the CRS. The results show that the coverage of a wireless network in a nearly open area can be extended by more than 9.3 km in the TVWS. Experimental results also confirm that the proposed FB-based RF transceiver is adequate for utilization in TVWS applications.

Evaluation of Filter Media for Use in Alpha Measurement of Radon Progeny (라돈 자핵종의 알파 측정용 여과지 매질의 평가)

  • Seo, Kyung-Won;Knutson Earl O.
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.31-41
    • /
    • 1992
  • A study for the evaluation of selected filter media that need further characterization particularily in the context of alpha measurements of radon progeny has been carried out by investigating physical characteristics and using the alpha spectroscopy. Physical characteristics was investigated by electrostatic charging and mechanical strength of filters, and then pressure drop before and after sampling was tested. Alpha spectroscopy was used to analyze the energy spectra from the deposition of radon progeny into filters. The results of the assessment showed that the newer filter types do not have a great advantage over the 'old standard' Millipore type AA. But Metricel DM-800 is recommended for those situations where electrostatic charging is a problem. Also this method will be used more effective for the evaluation of new developing filters in future.

  • PDF

Evaluation of Removal Efficiency of Pollutants in Constructed Wetlands for Treating Greenhouse Wastewater Under Different Filter Media, Configuration Methods and Agricultural Water Loading (시설하우스 농업배수 처리를 위한 인공습지에서 여재종류, 조합방법 및 부하량에 따른 오염물질 정화효율 평가)

  • Lee, Dong-Jin;Park, Jong-Hwan;Kim, Seong-Heon;Yoon, Chan-Woong;Cho, Ju-Sik;Lee, Seong-Tae;Heo, Jong-Soo;Seo, Dong-Cheol
    • Korean Journal of Ecology and Environment
    • /
    • v.47 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • To obtain optimum filter media, configuration method and greenhouse wastewater loading in small-scale constructed wetlands (CWs) for treating greenhouse wastewater, the apparatuses were constructed with 4 kinds of combined systems such as vertical flow (VH)-Horizontal flow (HF), HF-VH, HF-VF-HF, VF-HF-HF CWs. The efficiencies of pollutants in greenhouse wastewater were investigated in various CWs under different filter media, configuration methods and agricultural water loading. Removal rates of pollutants under different filter media were in the other of coarse sand>broken stone${\fallingdotseq}$calcite${\fallingdotseq}$mixed filter media for COD, broken stone>mixed filter media>coarse sand>calcite for T-N, and calcite>mixed filter media>broken stone>coarse sand for T-P. The removal rates of pollutants in HF-VH-HF CWs at different configuration methods were higher than those in other configuration methods. The removal rates of pollutants were higher in the order of $150L\;m^{-2}day^{-1}{\fallingdotseq}300L\;m^{-2}day^{-1}$ > $600L\;m^{-2}day^{-1}$ under different greenhouse wastewater loading. Therefore, optimum configuration method was HF-VH-HF CWs, the optimum filter media was mixed filter media (coarse sand : broken stone : calcite=1 : 1 : 1), and the optimum greenhouse wastewater loading was $300L\;m^{-2}day^{-1}$ in HF-VH-HF CWs.

Effect of Hydraulic Retention Time on Biological Nitrogen Removal in Land-based Fish Farm Wastewater (육상양식장 배출수내 생물학적 질소처리시 수리학적 체류시간의 영향)

  • Park, Noh-Back
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.50 no.3
    • /
    • pp.250-256
    • /
    • 2017
  • This study investigated the removal efficiency of organic matter and nitrogen from fish farm effluent by hydraulic retention time (HRT) using an upflow biological filter (ANR system) reactor. The recycling time and influent flow in the reactor were controlled to 14.8, 7.4, 5.5 and 3.2 h to evaluate HRT. In addition, each reactor was coupled to a fixed bed upflow filter charged with media. The results showed that removal efficiency was ${\geq}95%%$ with an HRT of 5.5 h, and nitrification efficiency was reduced to 81% with an HRT of 3.2 h, although nitrification efficiency temporarily decreased due to the shock load as HRT decreased. Total nitrogen removal rate was also reduced to about 65% with an HRT of 3.2 h, which was considered a washout effect of nitrifying and denitrifying microorganisms by increasing the shearing force to the filter media, which decreased organic matter and nitrogen removal efficiency.

Waste Treatment by an Anaerobic Filter (혐기성(嫌氣性) Filter Media 반응조(反應槽)에 의한 폐수처리(廢水處理))

  • Lee, Chan Ki;Rim, Jae Myung
    • Journal of Industrial Technology
    • /
    • v.2
    • /
    • pp.33-44
    • /
    • 1982
  • This study mainly concentrated on the treatment of nightsoil by an anaerobic filter media process. Nightsoil has been one of the major water pollutants in this couotry. It represents high ROD and SS concentrations. A comprehensive laboratory study conducted at Kangwoon National University indicate: (1) In the case of anaerobic filter system, COD and BOD removal efficiencies were greatly influenced by hydraulic retention time(HRT), but SS removal efficiencies dropped slowly when HRT were 2~13 days. (2) COD removal efficiencies were 19% when HRT were 15 days, 14% when HRT were 8 days, 10% when HRT were 6 days, 9% when HRT were 4 days, 2% when HRT were 2 days. (3) BOD removal efficiencies were 23% when HRT were 15 days, 14% when HRT were 8 days, 18% when HRT were 6 days, 7% when HRT were 4 days, 5.8% when HRT were 2days. (4) SS removal efficiencies were 21%~25%(2~15 days HRT).

  • PDF