• Title/Summary/Keyword: Filter Media

Search Result 795, Processing Time 0.026 seconds

A Experimental Study of Optimum Filter System Design of High Purity Polymer Thread Machine (고순도 Polymer 방사기계 필터 시스템 최적설계 기술 개발에 관한 실험적 연구)

  • Oh, T.H.;Kim, C.S.;Song, D.J.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.514-519
    • /
    • 2000
  • Predicting a pressure drop between inlet and outlet of the filter system is essential in designing the optimum filter system. This experiment has been carried out to investigate several design parameters which influence in a pressure drop, such as different tube length and metal fiber filter mesh size. A 1/50 scale filter system was made to simulate a real filter system. Results are compared with Darcy equation for a porous media.

  • PDF

Performance evaluation of CNN-based in-loop filter for HEVC (CNN 기반 HEVC 루프 필터의 성능 비교)

  • Lee, So Yoon;Hong, Jin Hyung;Oh, Byung Tae
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2017.11a
    • /
    • pp.74-76
    • /
    • 2017
  • In this paper, we introduce the CNN-based in-loop technology for HEVC, and analyze the performance of these algorithms through comparative experiments. The current in-loop filters in HEVC are composed of a deblocking filter that removes noise and a sample adaptive offset filter that compensates for signal offsets. A couple of CNN-based filters replacing the roles of these two algorithms are selected and compared.

  • PDF

Comparison of Filter Selection for Compressed Sensing (압축센싱을 위한 필터선택 비교)

  • Pham, Phuong Minh;Shim, Hiuk Jae;Jeon, Byeungwoo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2012.11a
    • /
    • pp.188-190
    • /
    • 2012
  • Compressed Sensing (CS) has been developed for several years. Among many CS algorithms for image, the Block-based Compressed Sensing with Smoothed Projected Landweber (BCS-SPL) demonstrates its excellent performance in low-complexity and near-optimal reconstruction. Several noise filtering algorithms of image reconstruction have been introduced such as the Wiener or the median filters, etc. In general, each filter has its own advantages and disadvantages depending on specific coding scheme. In this paper, we show that reconstruction performance can be varied according to the choice of filter. When a sub-rate value is changed, different filter causes different effect as well. Concerning the sub-rate, an inner filter can be chosen to improve the reconstructed image quality.

  • PDF

FUZZY-FILTER-BASED APPROACH TO RESTORATION OF THE OLD MOVIES

  • Tomohisa-Hoshi;Takashi-Komatsu;Takahiro-Saito
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.29-34
    • /
    • 1999
  • We present a practical method for removing biotches and restoring their mission data. To detect blotches, we employ a robust approach of local analysis of spatiotemporal anisotropic brightness continuity Our approach uses first-order spatiotemporal directional derivatives to select the smoothest direction for each examined pixel, and puts out the incorruption probability that he examined pixel may not be corrupted by blotches. As the restoration filter, were employ a spatiotemporal fuzzy filter whose response is adaptively controlled according to a fuzzy rule defined by the incorruption probability. The fuzzy filter is composed of the two different filter of the identity filter and the spatiotemporal directional-weighted-mean filter, and will put out an intermediate value between the original input brightness and the directional-weighted-mean brightness. We design the fuzzy rule in advance by a standard supervised learning fuzzy rule in advance by a standard supervised learning method. The computer simulations are presented.

Inactivation and Filtration of Bioaerosols Using Carbon Fiber Ionizer Assisted Activated Carbon Fiber Filter (탄소섬유 이오나이저를 적용한 활성탄소섬유 필터의 바이오에어로졸 항균 및 집진 성능평가)

  • Kim, Doo Young;Park, Jae Hong;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.185-192
    • /
    • 2010
  • This paper reports that the installation of a carbon fiber ionizer in front of an activated carbon fiber(ACF) filter enhanced the antibacterial efficiency. In addition, the effect of the ionizer on the filtration of bioaerosols is reported. Negative air ions from the ionizer were used as antibacterial agent. The test bacteria(Escherichia coli) were aerosolized using an atomizer and were deposited on the ACF filter media for 10 minutes. E. coli deposited on the filter were exposed to negative air ions for 0, 1, 5 and 10 minutes. Then they were separated from the ACF filter by shaking incubation with nutrient broth for 4 hours. The separated E. coli were spread on nutrient agar plates and incubated at $37^{\circ}C$ for 1~3 days. The antibacterial efficiency of E. coli was measured using a colony counting method. The antibacterial efficiencies of E. coli exposed to negative air ions for 1, 5 and 10 minutes were 14%, 48% and 71%, respectively. The filtration efficiency was evaluated by measuring the number concentration of bioaerosols at the upstream and downstream of the filter media. The increase of filtration efficiency by air ions was 14%, that is similar to the 17% filtration efficiency by none air ions. The ozone concentration was below the detection limit (under 0.01ppm) when the carbon fiber ionizers were on.

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

The Recycling Water Treatment of High Density Fish Culture System Using the Aerated Submerged Filter -1. Ammonia Removal Characteristics in Sea Water- (폭기식 잠수여상을 이용한 고밀도 양식장의 순환수 처리 -1. 해수중의 암모니아 제거 특성-)

  • LEE Heon-Mo;LEE Jae-Kwan;JUNG Byung-Gon;YANG Byung-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.5
    • /
    • pp.502-509
    • /
    • 1993
  • Submerged filter process was used to evaluate the nitrifying efficiency of ammonia in the recycling water of marine aquatic culture system. The ammonia removal efficiency was achieved as high as $99\%$ at the hydraulic surface loading rate of up to $4.3{\ell}/m^2-day$. And the nitrite accumulation did not occur in the reactor even when the hydraulic surface loading rate of up to $36.8{\ell}/m^2day$ was applied. In the present study, the relationship between the effluent ammonia concentration and ammonia surface loading rate was formulated as an equation. The attachment rate of biofilm on the filter media at the ammonia surface loading rate of 62.3 and $311.7mg/m^2day$ was 15 and $55mg/m^2-day$, respectively, showing the linear relationship between the attachment rate and ammonia loading rates. Biofilm thickness and density of the filter media were found to be the function of the ammonia loading rate.

  • PDF

Preliminary Study on the Measurement of the Electrostatic Charging State of PM2.5 Collected on Filter Media

  • Okuda, Tomoaki;Yoshida, Tetsuro;Gunji, Yuma;Okahisa, Shunichi;Kusdianto, K.;Gen, Masao;Sato, Seiichi;Lenggoro, I. Wuled
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.2
    • /
    • pp.137-145
    • /
    • 2015
  • This study focused on the measurement of the actual charging state of ambient aerosol particles, which is important for understanding the intricate process of adverse health effects caused by particulate matter (PM). The net electrostatic charging state of $PM_{2.5}$ collected on filter media was measured in this study. The Faraday cage method and surface potential measurements were used in this study. The results showed that the polarities of the net charging state measured using these two methods were in agreement for 42 out of 48 samples (87.5%), and 36 samples (75%) were negatively charged. The filters were not significantly charged by friction between the filters and air not containing PM. Charge addition to or leakage from the filters was not observed over a two-month storage period. Net charging state of $PM_{2.5}$ collected on the filters was concluded to be negative in most cases, based on data's support of the assumption that aerosol charging state is not altered by the process of PM collection using filter.

Characteristic Analysis of Electret Filters made by Electrospinning (전기방사를 통한 정전필터제조 및 특성분석)

  • Ahn, Young-Chull;Kim, Gil-Tae;Kim, Seong-Kon;Lee, Jae-Keun;Kim, Jong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1134-1138
    • /
    • 2008
  • Electret filter media are used in general ventilation filters, disposable respirators, vehicle cabin filters, vacuum cleaners and room air cleaners. There are basic mechanisms of interception, inertial impaction, diffusion, gravitational settling, electrostatic attraction by which an aerosol particle can be deposited onto a fiber in a filter. The ability of fine particle removal strongly depends on the electrostatic forces between particles and polarized fibers. Thus, the stability of the fiber polarization is a major factor in the reliability of electret filters. In this study, electrical properties and filtration performance of electrospun filter media are quantitatively investigated. Electrical properties of electrospun filters have been studied on surface charge potential and surface charge density. Also the filtration performance of the electret filters are evaluated on collection efficiency. Electrospun filters show same collection efficiency with low pressure drop compare to commercialized HEPA filters. Surface charge potential and surface charge density of electrospun filters are increased with increasing applied voltage. Also collection efficiency of electrospun filters is increased with increasing surface charge potential and surface charge density.

  • PDF

Demosaicking of Hexagonally-Structured Bayer Color Filter Array (육각형 구조의 베이어 컬러 필터 배열에 대한 디모자익킹)

  • Lee, Kyungme;Yoo, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1434-1440
    • /
    • 2014
  • This paper describes a demosaicking method for hexagonally-structured color filter array. Demosaicking is essential to acquire color images using color filter array (CFA) in single sensor imaging. Thus, CFA patterns have been discussed in order to improve image quality in single sensor imaging after the Bayer pattern are introduced. Advancements in imaging sensor technology recently introduce a hexagonal CFA pattern. The hexagonal CFA can be considered to be a 45-degree rotational version of the Bayer pattern, thus demosaicking can be implemented by an existing method with backward and forward 45-degree rotations. However, this approach requires heavy computing power and memory in image sensing devices because of the image rotations. To overcome this problem, we proposes a demosaicking method for a hexagonal Bayer CFA without rotations. In addition, we introduce a weighting parameter in our demosaicking method to improve image quality and to unifying exiting method with our method. Experimental results indicate that the proposed method is superior to conventional methods in terms of PSNR. In addition, some optimized values for the weighting parameter are provided experimentally.