Characterization of depth filter media for gas turbine intake air cleaning

  • Park, Young Ok;Hasolli, Naim;Choi, Ho Kyung;Rhee, Young Woo
    • 한국입자에어로졸학회지
    • /
    • 제5권4호
    • /
    • pp.159-170
    • /
    • 2009
  • A depth filter medium was newly designed in order to achieve high collection of dust and low pressure drop in this work. Multilayer depth filter media consist of an upstream layer of highly porous structure which allows particles to pass through and to follow by one or more downstream layers to hold the particles inside the media. For each filter media, flat sheet and pleated module were made of newly developed depth filter media and filter media of commercial products. Commercial depth filter cartridge for gas turbine air intake cleaning were used as reference for filtration area and pleat geometry of pleated modules. This work attempts to evaluate and compare the newly developed depth filter medium and two commercial filter media in terms of filtration parameters such as air permeability, initial pressure drop, particle retention and pressure drop variation with dust loading. According to the close examination the newly developed depth filter showed better performance compared to the commercial depth filter media.

  • PDF

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

Active Min-Depth Filter를 이용한 비분할 장애물 최근접 점 검출 (Detection of Nearest Points without Obstacle Segmentation using Active Min-Depth Filter)

  • 박경균;정문호
    • 한국전자통신학회논문지
    • /
    • 제18권1호
    • /
    • pp.77-84
    • /
    • 2023
  • 자율 주행 로봇에서 장애물 회피 기능은 핵심적인 것이다. 포텐셜 필드는 이 분야에 가장 많이 사용되어온 방법이다. 이것은 장애물의 최근접 점을 실시간으로 계산해야 하는데 이를 위해 거리 센서 데이터 프로파일로 부터 안정적으로 장애물 영역을 분할해야 하는 어려움이 있다. 본 논문에서는 분할 없이 각 장애물의 최근접 점을 실시간으로 구할 수 있는 Active Min-Depth Filter를 제안한다. 다양한 센서 노이즈 환경에 대한 시뮬레이션을 통해 Active Min-Depth Filter의 강인성을 확인할 수 있었고 실제 이동 로봇 적용하여 성공적인 결과를 얻었다.

산업용 심층여과 카트리지 필터 (Depth Cartridge Filter for Industrial Liquid Filtration)

  • 남상용;심홍섭;이영무;최영옥
    • 멤브레인
    • /
    • 제19권3호
    • /
    • pp.173-182
    • /
    • 2009
  • 심층형여과 카트리지필터는 반도체 등 전자재료, 식음료, 각종 안료, 페인트, 잉크 등의 공정용 카트리지 필터로서 널리 사용되고 있는 필터이다. 이러한 공정용 카트리지 필터의 여과특성과 심층형여과 카트리지 필터의 종류, 제조업체 및 전세계 시장동향을 살펴보고, 심층형여과 카트리지 필터의 고장사례현황 및 원인규명과 함께, 신뢰성평가 방법에 대하여 고찰하였다.

깊이영상의 전처리를 이용한 다시점 영상 생성 방법 (Multi-view Image Generation by Depth Map Preprocessing)

  • 이상범;김성열;호요성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.697-698
    • /
    • 2006
  • In this paper, we propose a new scheme to generate multi-view images using a depth-image-based rendering (DIBR) technique. In order to improve the quality of multi-view images at newly exposed areas during mesh-based rendering, we preprocess the depth map using a Gaussian smoothing filter. Previous algorithms apply a smoothing filter to the whole depth map even if the depth map is collapsed. After extracting objects from the depth map, we apply the smoothing filter to their boundaries. Finally, we cannot only maintain the depth quality, but also generate high quality multi-view images. Experimental results show that our proposed algorithm outperforms previous works and supports an efficient depth keying technique.

  • PDF

Gabor Filter를 이용한 소실선 검출 기반의 깊이 지도 생성 기법 (Generation Method of Depth Map based on Vanishing Line using Gabor Filter)

  • 유태훈;이상훈
    • 한국융합학회논문지
    • /
    • 제3권1호
    • /
    • pp.13-17
    • /
    • 2012
  • 본 논문에서는 기하학적 단서인 소실선과 텍스처를 이용하여 깊이 지도를 생성하는 방법을 제안한다. 소실선은 영상 내 존재하는 평행한 직선들에 의해 생성되는 것으로 영상에서 Gabor Filter를 통해 특정 각도의 경계를 추출하고 이를 허프 변환을 통해 직선을 추출하여 소실선을 검출해낸다. 검출된 소실선에 따라 초기 깊이 지도를 생성하고 텍스처 단서인 슈퍼 픽셀을 이용한 상대적 깊이 지도를 결합하여 최종 깊이 지도를 생성한다. 소실선을 이용한 초기 깊이지도와 슈퍼 픽셀을 이용한 상대적 깊이 지도를 결합함으로써 보다 신뢰성 있는 깊이 지도가 생성되었다.

3 차원 영상 시스템의 깊이영상 후처리 필터 성능 비교 (Performance Comparisons of Depth Map Post Processing for 3D Video System)

  • 이도훈;윤은지;오병태
    • 한국방송∙미디어공학회:학술대회논문집
    • /
    • 한국방송공학회 2014년도 하계학술대회
    • /
    • pp.81-83
    • /
    • 2014
  • 본 논문에서는 3 차원 영상시스템의 성능향상을 위한 깊이영상의 여러 후처리 필터들의 성능을 비교 실험한다. 성능비교를 위해 현재 3D-ATM 에 쓰이고 있는 dilation 필터와, 경계값 보존에 탁월한 성능을 보이는 bilateral 필터, 그리고 깊이영상의 특성을 이용한 depth boundary reconstruction 필터를 선정하였다. 본 논문에서는 위 제시한 필터들의 특징에 대하여 소개하고, 이들 필터들이 3 차원 영상 시스템의 깊이영상에 적용되었을 때 어느정도 성능향상을 보이는지 비교 분석한다.

  • PDF

A New Depth and Disparity Visualization Algorithm for Stereoscopic Camera Rig

  • Ramesh, Rohit;Shin, Heung-Sub;Jeong, Shin-Il;Chung, Wan-Young
    • Journal of information and communication convergence engineering
    • /
    • 제8권6호
    • /
    • pp.645-650
    • /
    • 2010
  • In this paper, we present the effect of binocular cues which plays crucial role for the visualization of a stereoscopic or 3D image. This study is useful in extracting depth and disparity information by image processing technique. A linear relation between the object distance and the image distance is presented to discuss the cause of cybersickness. In the experimental results, three dimensional view of the depth map between the 2D images is shown. A median filter is used to reduce the noises available in the disparity map image. After the median filter, two filter algorithms such as 'Gabor' filter and 'Canny' filter are tested for disparity visualization between two images. The 'Gabor' filter is to estimate the disparity by texture extraction and discrimination methods of the two images, and the 'Canny' filter is used to visualize the disparity by edge detection of the two color images obtained from stereoscopic cameras. The 'Canny' filter is better choice for estimating the disparity rather than the 'Gabor' filter because the 'Canny' filter is much more efficient than 'Gabor' filter in terms of detecting the edges. 'Canny' filter changes the color images directly into color edges without converting them into the grayscale. As a result, more clear edges of the stereo images as compared to the edge detection by 'Gabor' filter can be obtained. Since the main goal of the research is to estimate the horizontal disparity of all possible regions or edges of the images, thus the 'Canny' filter is proposed for decipherable visualization of the disparity.

산화망간피복여재를 이용한 용존망간 제거 (Soluble Manganese Removal Using Manganese Oxide Coated Media (MOCM))

  • 김진근;정세채;고수현
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.813-822
    • /
    • 2006
  • Soluble manganese removal was analyzed as a function of filter media, filter depth, presence or absence of chlorination, and surface manganese oxide concentration in water treatment processes. Sand, manganese oxide coated sand (MOCS), sand+MOCS, and granular activated carbon(GAC) were used as filter media. Manganese removal, surface manganese oxide concentration, turbidity removal, and regeneration of MOCS in various filter media were investigated. Results indicated that soluble manganese removal in MOCS was rapid and efficient, and most of the removal happened at the top of the filter. When filter influent (residual chlorine 1.0mg/L) with an average manganese concentration of 0.204mg/L was fed through a filter column, the sand+MOCS and MOCS columns can remove 98.9% and 99.2% of manganese respectively on an annual basis. On the other hand, manganese removal in sand and the GAC column was minimal during the initial stage of filtration, but after 8 months of filter run they removed 99% and 35% of manganese, respectively. Sand turned into MOCS after a certain period of filtration, while GAC did not. In MOCS, the manganese adsorption rate on the filter media was inversely proportional to the filter depth, while the density of media was proportional to the filter depth.

A laboratory study on synthetic fiber filter for further treatment of turbid stormwater from construction sites

  • Yuan, Qingke;Kim, Youngchul
    • Membrane and Water Treatment
    • /
    • 제10권2호
    • /
    • pp.105-112
    • /
    • 2019
  • On the purpose of conform the more stringent government regulation for turbid stormwater from construction sites, the feasibility and availability of synthetic fiber placing after the conventional protection barrier were tested in this study. Initially, comparative work on the filtering performance of fiber media and conventional gravel filter was carried out, 27% higher filtration capacity was obtained under the similar operational conditions. The filter efficiency was about 20 to 52% with a varying filter depth of 5 to 15cm, presuming at extreme storm flow conditions (800-1500 m/day of filtration rates). Fiber filter was found to have a similar filtration prosperity as grain media; namely, the separation efficiency is directly and inversely proportional to filter depth and rate, respectively. The effects of filter aid (polyaluminium chloride) on filter performance was also investigated, it greatly affected the turbidity reduction at the dosage of 2 mg/L. At the time of breakthrough, a simple filter washing was carried out, herein, the solid recovery achieved over than 88% and greatly determined by operational parameters. Based on the operational data, the empirical models aimed for predicting filtration efficiency were established, which can effectively determine the required filter depth and filtration area in field.