• 제목/요약/키워드: Film-Cooling

검색결과 441건 처리시간 0.022초

Water film covering characteristic on horizontal fuel rod under impinging cooling condition

  • Penghui Zhang;Bowei Wang;Ronghua Chen;G.H. Su;Wenxi Tian;Suizheng Qiu
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.4329-4337
    • /
    • 2022
  • Jet impinging device is designed for decay heat removal on horizontal fuel rods in a low temperature heating reactor. An experimental system with a fuel rod simulator is established and experiments are performed to evaluate water film covering capacity, within 0.0287-0.0444 kg/ms mass flow rate, 0-164.1 kW/m2 heating flux and 13.8-91.4℃ feeding water temperature. An effective method to obtain the film coverage rate by infrared equipment is proposed. Water film flowing patterns are recoded and the film coverage rates at different circumference angles are measured. It is found the film coverage rate decreases with heating flux during single-phase convection, while increases after onset of nucleate boiling. Besides, film coverage rate is found affected by Marangoni effect and film accelerating effect, and surface wetting is significantly facilitated by bubble behavior. Based on the observed phenomenon and physical mechanism, dry-out depth and initial dry-out rate are proposed to evaluate film covering potential on a heating surface. A model to predict film coverage rate is proposed based on the data. The findings would have reliable guide and important implications for further evaluation and design of decay heat removal system of new reactors, and could be helpful for passive containment cooling research.

고온 실린더의 미스트 냉각 (Mist Cooling of High-Temperature Cylinder Surface)

  • 김무환;이수관;박지만;이필종
    • 대한기계학회논문집B
    • /
    • 제26권3호
    • /
    • pp.448-457
    • /
    • 2002
  • Heat treatment such as quenching of a high-temperature cylinder is being used on steel to produce high strength levels. Especially, the mist cooling with the high and uniform surface heat flux rate s expected to contribute for better products. The experimental mist cooling curve is produced for better understanding, and two distinct heat transfer regions are recognized from the cooling curve produced. It is shown that the liquid film evaporation dominated region follows the film boiling-dominated region as decreasing the temperature of test cylinder by mist flow. Based on the intuitive view from some previous investigations, a simplified model with some assumptions is introduced to explain the mist cooling curve, and it is shown that the estimation agrees well with our experimental data. In the meanwhile, it is known that the wetting temperature, at which surface heat flux rate is a maximum, increases with mass flow rate ratio of water to air ($\varkappa$ < 10). However, based on our experimental data, it is explained that there exists a critical mass flow rate ratio, at which the wetting temperature is maximum, in the range of 3 < $\varkappa$ < 130. Also, it is described that despite of the same value of $\varkappa$, the wetting temperature may increase with mist velocity.

필름 냉각을 위한 리브드 채널의 홀 위치에 따른 열전달 특성 수치 해석 (Numerical Analysis of Heat Transfer Characteristics of Ribbed Channels with Different Film Cooling Hole Position)

  • 박지민;문주현;이형주;이성혁
    • 한국산학기술학회논문지
    • /
    • 제19권9호
    • /
    • pp.69-76
    • /
    • 2018
  • 본 연구에서는 가스터빈 블레이드의 필름 냉각에서 45도 리브가 있는 냉각채널의 필름 홀 위치가 블레이드의 표면냉각 성능에 미치는 영향을 전산유체해석 기법을 통하여 분석하였다. 또한 냉각채널의 리브 유무의 영향을 동일 분사율에 대해서 고찰하였다. 수치해석 도메인은 3차원으로 구성하였고 상용코드(Fluent ver. 17.0)를 사용하여 정상상태 조건 하에서 수치해석을 진행하였다. 그 결과를 바탕으로 블레이드 표면에서의 냉각효율, 유속, 유선, 압력 계수를 비교 분석하였고 홀 위치의 변화가 리브 구조에 의해 유발되는 이차 유동의 토출에 미치는 영향을 고찰하였다. 수치해석 결과로부터 리브가 설치되어 있는 경우 냉각채널의 내부유동은 상부에서 반시계 방향 및 하부에서 시계 방향의 와류쌍을 형성하는 것을 확인할 수 있었다. 리브가 있는 채널의 경우 리브에 의하여 발생한 와류유동이 홀 출구 부근에서 더 높은 압력 차이를 유발하여 리브가 없는 경우보다 최소 12% 이상의 높은 냉각 효율을 나타냈다. 또한 리브가 있는 채널 중에서 홀이 좌측에 위치한 경우(Rib-Left) 리브에 의하여 발생한 이차 유동이 홀 부근의 벽면에 부딪혀 홀 경사각 방향으로의 유동이 형성되는 것을 확인하였다. 블레이드 표면으로 토출된 냉각기체가 주 유동 경계층 내부에서 머무는 영역이 다른 케이스에 비하여 넓기 때문인 것으로 사료된다. 또한 이 경우 홀 출구 부근에서 가장 큰 압력 계수 차이를 나타내었고 이로 인하여 냉각기체의 토출이 촉진되어 냉각효율이 다소 증가하였다.

다공물질 표면처리가 경사판의 증발냉각에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effects of Porous Layer Treatment on Evaporative Cooling of an Inclined Surface)

  • 이대영;이재완;강병하
    • 설비공학논문집
    • /
    • 제17권1호
    • /
    • pp.25-32
    • /
    • 2005
  • Falling film heat transfer has been widely used in many applications in which heat and mass transfer occur simultaneously, such as evaporative coolers, cooling towers, absorption chillers, etc. In such cases, it is desirable that the falling film spreads widely on the surface forming thin liquid film to enlarge contact surface and to reduce the thermal resistance across the film and/or the flow resistance to the vapor stream over the film. In this work, the surface is treated to have thin porous layer on the surface. With this treatment, the liquid can be spread widely on the surface by the capillary force resulting from the porous structure. In addition to this, the liquid can be held within the porous structure to improve surface wettedness regardless of the surface inclination. The experiment on the evaporative cooling of an inclined surface has been conducted to verify the effectiveness of the surface treatment. It is measured that the evaporative heat transfer increases about $50\%$ by the porous layer treatment as compared with that from orignal bare surfaces.

암모니아 흡수식 열펌프의 Falling Film Type 흡수기에 대한 수학적 모델링 및 수치모사에 관한 연구 (Mathematical modeling and numerical simulation studies for falling film type absorber in ammonia absorption heat pump)

  • 이찬호;김성현;현재천
    • 청정기술
    • /
    • 제7권2호
    • /
    • pp.151-159
    • /
    • 2001
  • 암모니아 흡수식 열펌프의 falling film type 흡수기에 대한 수학적 모델링 및 수치모사 연구를 수행하였다. 기존의 수학적 모델에 열역학적 물성을 온도의 함수로 적용하여 수치모사를 수행하였고 이로부터 얻은 결과를 실험결과와 비교함으로써 모델의 성능이 향상되는 것을 확인하였다. 그리고 개발된 모델을 이용하여 냉각수의 유량과 온도가 흡수기내에서 일어나는 열 및 물질전달에 미치는 영향을 평가하였다. 수치모사 결과로부터 냉각수 온도가 낮을수록 유량이 증가할수록 열 및 물질전달 효율이 증가하는 것을 알 수 있었다.

  • PDF

대학 건물에 적용한 열 차단 필름이 냉방부하에 미치는 영향 평가 (The Evaluation of Cooling Load by The Window Film Insulation in College Building)

  • 김석현;강수현;유시완;조영흠
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.549-552
    • /
    • 2012
  • Recently the world is trying to reduce carbon emissions for global warming. Reducing use of fossil fuels can decrease carbon emission. In this reason the construction field has tried to reduce the use of fossil fuels relating to heating and cooling of buildings. An energy loss through the window system is about 10 to 30 percent of energy consumption of the whole building. The use of window film insulation is increasing to control the heat loss at the windows. The window film insulation absorbs solar radiation and makes the surface temperature of windows high. In this study, window surface temperature is measured, and an impact on indoor air is identified after attaching window film insulation. Finally, we found that cooling load decreases through simulation.

  • PDF

물-공기 혼합분무에 의한 고온 강판 냉각에 대한 연구 (I) -막비등 열전달에 대한 공기질량유속의 영향- (A Study on Cooling of Hot Steel Surface by Water-Air Mixed Spray(I) -The Effect of Air Mass Flux on Film Boiling Heat Transfer-)

  • 이필종;진성태;이승홍
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.247-255
    • /
    • 2004
  • The cooling characteristic of water-air mixed spray for high water mass flux is not well defined, compared to that of highly pressurized spray. A series of research program was planned to develop the boiling correlation for whole temperature range in case of water-air mixed spray with high water mass flux. The cooling experiments of hot steel surface with initial temperature of 820$^{\circ}C$ were conducted in unsteady state with relatively high water mass flux. A computer program was developed to calculate the heat flux inversely from measured data by three inserted thermocouples. Finally the effects of water and air mass flux on the averaged film boiling heat flux and wetting temperature were studied. In this 1st report, it is found that the boiling curve was similar to that of highly pressurized spray and the decreased slope of heat flux in film boiling region with respect to surface temperature became steep by increasing air mass flux. Also it is shown that, by increasing air mass flux, the averaged heat flux in film boiling region was increased, and then saturated and the wetting temperature was increased, and then decreased. Finally when the heat flux in film boiling region is compared with that of highly pressurized spray, it is known that the cooling is improved by introducing air up to 60%.

충돌 액막 분석을 위한 전기전도 액막 두께 측정장치 최적설계 (Optimum Design of a Liquid Film Thickness Measurement Device Using Electric Conductance for Impingement Liquid Film)

  • 이형원;이현창;김태성;안규복;윤영빈
    • 센서학회지
    • /
    • 제27권6호
    • /
    • pp.386-391
    • /
    • 2018
  • To analyze the film cooling in a liquid rocket engine, it is necessary to understand the characteristics of the wall-impingement liquid film. We designed an optimal two-dimensional device for measuring the thickness of the liquid film thickness. This device quantitatively measures the liquid-film thickness distribution. In previous liquid-film thickness measuring devices, the liquid film was formed over the entire area of the sensor. However, its formation depended on injection conditions. To compensate for this, optimal resistors are selected. Additionally, saturation variations with partial saturation are analyzed. Furthermore, calibration using the enhanced plate method is conducted with improvements in spatial resolution. The device designed here can be used to analyze the properties of an impingement liquid film with a slit injector. This study can be used for film-cooling analysis in liquid rocket engines.

이산화탄소를 이용한 가스터빈 블레이드 막냉각 특성 연구 (A Numerical Study on the Film-Cooling Characteristics of Gas Turbine Blade using CO2)

  • 김상권;이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.41-44
    • /
    • 2012
  • In order to cool the turbine blade under high temperature operating conditions, the film-cooling method is generally applied. In this study, $CO_2$ was used as working fluid and it helped the operating system to prevent the loss of compressed air. The trapezoidal diffuser shape was adopted at the cross section of hole and the characteristics of heat flow with various working fluids were numerically studied. In particular, the different mixture ratios of $CO_2$, such as various density ratios of 0.2, 0.8, and 1.0, respectively, were considered. Numerical results are graphically depicted with various conditions.

ZnO 박막의 RF 마그네트론 스퍼터 증착 중 미리 가열된 기판의 자연냉각 효과 (The Natural Cooling Effects of Pre-heated Substrate during RF Magnetron Sputter Deposition of ZnO)

  • 박성현;이능헌
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.905-909
    • /
    • 2007
  • Crystalline and micro-structural characteristics of ZnO thin films which were deposited on p-Si(100) with cooling naturally down of pre-heated substrate during RF magnetron sputter deposition, were investigated by XRD and SEM in this paper. The film which was prepared on the substrate which was pre-heated to $400^{\circ}C$ before deposition and then cooled naturally down during deposition, showed the most outstanding c-axis preferred orientation. The ZnO thin film having the best crystalline result were applied to SMR type FBAR device and resonance properties of the device were investigated by network analyzer. It showed that resonance frequency was 2.05 GHz, return loss was -30.64 dB, quality factor was 3169 and electromechanical coupling factor was 0.4 %. This deposition method would be very useful for application of surface acoustic wave filter or film bulk acoustic wave resonator.