• 제목/요약/키워드: Filling Machine

검색결과 115건 처리시간 0.029초

납품처가 다른 포장용 필름의 열접착 트러블 원인 규명에 관한 연구 (Study on the Investization of Hot Sealing Difference of the Same Flexible Packaging)

  • 박근실
    • 한국포장학회지
    • /
    • 제8권1호
    • /
    • pp.15-22
    • /
    • 2002
  • PET $16{\mu}m/dry$ lamination/Al-foil $7{\mu}m/dry$ lamination/CPP $80{\mu}m$의 사양으로 2개 업체에서 제조된 포장용 복합필름에서 제품 충전공정 중에서 발생한 열접착 트러블의 원인을 규명하고자 복합필름을 분리하여 각각의 두께와 재질이 제시된 사양과 일치하는지를 관능검사와 IR, DSC로 측정한 결과 1개 업체의 것이 차단층의 두께가 다르고 열접착층 필름의 재질은 비슷한 것임을 알았고, 시험기로 찾은 최적 열접착조건은 $195^{\circ}C$$210^{\circ}C$$15^{\circ}C$의 차이를 보였으며 이를 종형 4면 액체충전포장기로 직접 충전 포장하였을 때의 봉지의 열접착 강도를 비교한 결과 최적 열접착 조건 $195^{\circ}C$의 것은 평균 $4.76kg/cm^2/15mm,\;210^{\circ}C$의 것은 평균 $3.84kg/cm^2/15mm$이었다.

  • PDF

Effect of ultrasonic agitation on push-out bond strength and adaptation of root-end filling materials

  • Alcalde, Murilo Priori;Vivan, Rodrigo Ricci;Marciano, Marina Angelica;Duque, Jussaro Alves;Fernandes, Samuel Lucas;Rosseto, Mariana Bailo;Duarte, Marco Antonio Hungaro
    • Restorative Dentistry and Endodontics
    • /
    • 제43권2호
    • /
    • pp.23.1-23.9
    • /
    • 2018
  • Objectives: This study evaluated the effect of ultrasonic agitation of mineral trioxide aggregate (MTA), calcium silicate-based cement (CSC), and Sealer 26 (S26) on adaptation at the cement/dentin interface and push-out bond strength. Materials and Methods: Sixty maxillary canines were divided into 6 groups (n = 10): MTA, S26, and CSC, with or without ultrasonic activation (US). After obturation, the apical portions of the teeth were sectioned, and retrograde cavities were prepared and filled with cement by hand condensation. In the US groups, the cement was activated for 60 seconds: 30 seconds in the mesio-distal direction and 30 seconds in the buccal-lingual direction, using a mini Irrisonic insert coupled with the ultrasound transducer. After the materials set, 1.5-mm thick sections were obtained from the apexes. The presence of gaps and the bond between cement and dentin were analyzed using low-vacuum scanning electron microscopy. Push-out bond strength was measured using a universal testing machine. Results: Ultrasonic agitation increased the interfacial adaptation of the cements. The S26 US group showed a higher adaptation value than MTA (p < 0.05). US improved the push-out bond strength for all the cements (p < 0.05). Conclusions: The US of retrograde filling cements enhanced the bond to the dentin wall of the root-end filling materials tested.

Push-out bond strength of a self-adhesive resin cement used as endodontic sealer

  • Gurgel-Filho, Eduardo Diogo;Lima, Felipe Coelho;Saboia, Vicente De Paula Aragao;Coutinho-Filho, Tauby De Souza;Neves, Aline De Almeida;da Silva, Emmanuel Joao Nogueira Leal
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.282-287
    • /
    • 2014
  • Objectives: The aim of the present study was to investigate the bond strength of RelyX Unicem (3M) to root canal dentin when used as an endodontic sealer. Materials and Methods: Samples of 24 single-rooted teeth were prepared with Gates Glidden drills and K3 files. After that, the roots were randomly assigned to three experimental groups (n = 8) according to the filling material, (1) AH Plus (Dentsply De Trey GmbH)/Gutta-Percha cone; (2) Epiphany SE (Pentron)/Resilon cone; (3) RelyX Unicem/Gutta-Percha cone. All roots were filled using a single cone technique associated to vertical condensation. After the filling procedures, each tooth was prepared for a push-out bond strenght test by cutting 1 mm-thick root slices. Loading was performed on a universal testing machine at a speed of 0.5 mm/min. One-way analysis of variance and Tukey test for multiple comparisons were used to compare the results among the experimental groups. Results: Epiphany SE/Resilon showed significantly lower push-out bond strength than both AH Plus/Gutta-Percha and RelyX Unicem/Gutta-Percha (p < 0.05). There was no significant difference in bond strength between AH Plus/Gutta-Percha and RelyX Unicem/Gutta-Percha (p > 0.05). Conclusions: Under the present in vitro conditions, bond strength to root dentin promoted by RelyX Unicem was similar to AH Plus. Epiphany SE/Resilon resulted in lower bond strength values when compared to both materials.

이동형 아스팔트 재생기를 이용한 페아스팔트 콘크리트 혼합물의 재활용 (The Recycling of Waste Asphalt Concrete Mixfure Using a Movable Asphalt Recycling Machine)

  • 박승범;조청휘;김정환
    • 한국산학기술학회논문지
    • /
    • 제1권2호
    • /
    • pp.75-83
    • /
    • 2000
  • 최근 경제성장 및 국민 생활향상에 따라 폐기물 발생량이 급격하게 증대되어 그 처리문제가 심각해지고 있다. 이러한 폐기물중 노고 포장의 해체 및 유지·보수공사의 증가에 따라 다량 발생하고 있는 폐아스콘은 대부분 재활용되지 못하고 불법처분 또는 매립되고 있어 자원낭비 및 심각한 환경오염 문제를 야기하고 있는 실정이다. 따라서 본 연구에서는 폐아스콘의 재활용을 촉진하기 위하여 이동형 아스팔트 재생기 및 재생첨가제를 사용하여 양질의 신재 아스콘과 동등 수준의 품질을 갖춘 기층용 재생아스콘을 제조하기 위한 기초적 연구를 수행하였다.

  • PDF

매립석탄회를 혼합한 유동성 충진재의 동적거동특성 (Dynamic Characteristics of Liquidity Filling Materials Mixed with Reclaimed Ash)

  • 채덕호;김경오;신현영;조완제
    • 한국지반환경공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.5-11
    • /
    • 2014
  • 최근 도심지의 구조물 건설 시 다양한 라이프라인이 공간의 효율적인 활용 측면에서 지중에 매설되고 있으며, 이러한 라이프라인의 신설 및 유지보수 등을 위해 굴착이나 뒤채움 작업이 빈번하게 이루어지고 있다. 라이프라인 매설 시 지반을 굴착하며, 매설 후 채움재 모래를 사용하여 되메움을 하는 것이 일반적이다. 이러한 경우 통신관, 가스관, 상하수도 등의 관하부와 측면 좁은 공간의 뒤채움은 다짐작업이 어려우며, 다짐작업 시 토사의 특성상 추가적으로 침하가 발생한다. 이러한 문제점을 해결하기 위한 방법으로 미국 및 일본 등과 같은 선진국에서 건설 발생토를 재활용하여 잔토처리 비용을 줄이고, 충분한 유동성을 확보한 유동성 채움재가 사용되고 있다. 또한 지중 매설관 건설 외에도 기초 하부 지반의 보강에도 유동성 채움재를 활용할 수 있을 것으로 판단되며, 특히 기계 기초 하부 지지층이 연약한 경우, 유동성 채움재를 적용하여 빠른 시간 안에 지반을 개량하는 목적에 적합할 것으로 판단된다. 특히 기계 기초 하부 지지층의 경우, 단순한 기계 하중에 의한 정적 지지력 산정뿐만 아니라 기계의 진동에 의한 동적 하중이 가해지므로 기초 하부 지지층의 동적거동특성이 평가되어야 한다. 따라서 본 연구에서는 유동성 채움재를 기계 기초 지지층으로 활용하는데 있어서의 적용성을 판별하기 위해 국내에서 일반적으로 볼 수 있는 점토와 황토를 현장발생토로 가정하여 세립분 함량을 달리한 유동성 채움재의 강도 및 동적 거동특성을 파악하였다. 또한 현장 발생토를 대신하여 산업 폐기물인 매립석탄회를 활용하여 유동성 채움재를 조성하여 그 성능을 비교하였다. 그 결과, 매립석탄회를 혼합하여 사용한 경우, 일반적인 건설발생토를 사용한 경우보다 높은 7일 재령 강도와 전단탄성계수를 보였다.

주조기와 매몰재의 성분변화에 따른 티타늄의 주조성에 관한 연구 (THE EFFECT OF CASTING MACHINE AND INVESTMENT ON THE CASTABILITY OF TITANIUM ALLOY)

  • 정다운;양홍서
    • 대한치과보철학회지
    • /
    • 제44권5호
    • /
    • pp.654-664
    • /
    • 2006
  • Statement of problem: There has been a eat interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However, the melting temperature and chemical reactivity of titanium necessities casting system different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new development in Ti casting system, inadequate mold filling and internal porosity are frequently observed casting defects. Purpose : The purposes of this study were to compare the castibility and reaction layer of the casting titanium under the two casting machines and their investment condition. Material and method: coping and machine-milled titanium coping according to the casting methods and the marginal configurations. The total 28 specimens were used, and these are divided into 4 groups according to 2 casting machines and 2 investments. The castings were analyzed using x-ray microanalysis and microhardness testing. The reaction layer between margin of titanium casting and the investments was observed and analyzed with scanning electron microscope. Result: 1. Castabiliy of casting titanium specimen was best in the group of centrifugal casting machine and Selevest $CB^{\circledR}$ and good that of Selevest CB and pressure differential casting machine, Rematitan plus and centrifugal casting machine, Rematitan plus and pressure differential casting machine in order. 2. There was no significanct correlation in titanium castability in respect of casting machine. However ANOVA indicated that Selevest $CB^{\circledR}$ groups had significantly better castability than Rematitan $plus^{\circledR}$ groups.(p<0.05) 3. There was a significant microhardness difference between centrifugal casting machine groups and pressure differential groups.(p<0.05) Titanium castings in centifugal groups had significantly harder than those in pressure differential groups. 4. The addition of zirconia decreased interfacial reactivity. Conclusion: above result revealed that of the castability of titanium casting specimens had little correlation in casting machines and was better in magnesia-based investment contained ZrO2 groups. However in order to practice casting titanium in clininic, its castability should be improved, also there should be more research on factor of castability so that long-span prothesis and removable partial denture metla frame may be casted completly.

심미수복재의 수복방법과 광조사기기에 따른 치질과의 인장결합강도에 관한 연구 (A STUDY ON THE TENSILE BOND STRENGTH TO TOOTH STRUCTURE OF TOOTH COLORED MATERIALS ACCORDING TO FILLING METHODS AND LIGHT CURING UNITS)

  • 황호길;김영관;오행진
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.652-663
    • /
    • 1996
  • The purpose of this study was to evaluate the tensile bond strength to tooth structure of composite resin and glass ionomer cement according to filling methods and light curing units. In this study, two class V cavities were prepared on the buccal surface of each tooth of 140 extracted human molars, and they were randomly assigned into 3 experimental groups with 40 teeth and control group with 20 teeth. And then, each experimental groups subdivided into 2 groups(A,B) according to light curing units. The cavities of each group were filled with the CLEARFIL FII self curing resin(Control Group), Z-100 light curing resin(Group 1), Vitremer$^{TM}$ light curing glass ionomer cement(Group 2) and Z-100 light curing resin over the Vitrebond$^{TM}$ liner(Group 3). And subdivided A Group used Argon Laser(SPECTRUM$^{TM}$, U.S.A.), B Group used XL 1,000 curing light (3M, U.S.A.). The specimens underwent temperature changed from $5^{\circ}C$ to $55^{\circ}C$ five hundred times. After thermocycling, specimens were stored in 100% relative humidity at $37^{\circ}C$ for 24 hours. And then, the tensile bond strength of specimens were calculated with Universal Testing Machine(AGS-100A, Japan). The results were as follows : 1. Among the experimental groups, the group 2-B showed the highest tensile bond strength ($18.89{\pm}7.80$) and the group 1-A showed the lowest tensile bond strength ($11.68{\pm}2.28$). There was significant difference between group 2-B and group 1-A(p<0.01). 2. Between the light curing units, the XL 1,000 unit showed higher tensile bond strength ($16.63{\pm}3.20$) than that of the Argon Laser unit ($13.73{\pm}2.30$). There was significant difference between XL 1,000 and Argon Laser(p<0.01). 3. About filling methods and materials, the group 2 showed the highest tensile bond strength ($17.56{\pm}1.89$) and the group 1 showed the lowest tensile bond strength($13.03{\pm}1.90$). There was significant difference between group 2 and group 1,3(p<0.01). In conclusion, the results showed that the glass-ionomer cement that cured by XL 1,000 light curing unit demonstrated significantly higher tensile bond strength than other curing unit and filling methods.

  • PDF

기상모델자료와 기계학습을 이용한 GK-2A/AMI Hourly AOD 산출물의 결측화소 복원 (Spatial Gap-filling of GK-2A/AMI Hourly AOD Products Using Meteorological Data and Machine Learning)

  • 윤유정;강종구;김근아;박강현;최소연;이양원
    • 대한원격탐사학회지
    • /
    • 제38권5_3호
    • /
    • pp.953-966
    • /
    • 2022
  • 에어로솔(aerosol)은 대기 질을 악화시키는 등 인체 건강에 악영향을 끼치므로 에어로솔의 분포 및 특성에 대한 정량적인 관측이 필수적이다. 최근 전 지구 규모에서의 주기적이고 정량적인 정보 획득 수단으로 위성관측 Aerosol Optical Depth (AOD) 영상이 다양한 연구에 활용되지만 광학센서 기반의 위성 AOD 영상은 구름 등의 조건을 가진 일부 지역에서 결측을 가진다. 이에 본 연구는 위성자료의 결측복원을 위하여 격자형 기상자료와 지리적 요소를 입력변수로 하여 Random Forest (RF) 기반 gap-filling 모델을 생성한 이후, gap-free GK-2A/AMI AOD hourly 영상을 산출하였다. 모델의 정확도는 -0.002의 Mean Bias Error (MBE), 0.145의 Root Mean Square Error (RMSE)로, 원자료의 목표 정확도보다 높으며 상관계수 0.714로 복원 대상이 대기변수인 점을 감안하면 상관계수 측면에서도 충분한 설명력을 갖춘 모델이다. 정지궤도 위성의 높은 시간 해상도는 일변화 관측에 적합하며 대기보정을 위한 입력, 지상 미세먼지 농도 추정, 소규모 화재 또는 오염원 분석 등 타 연구를 위한 자료 활용 측면에서 중요하다.

유연하고 신속한 표면미세가공기술을 이용한 Micro-fluidic Channel 제작 (Fabrication of Micro-fluidic Channels using a Flexible and Rapid Surface Micro-machining Technique)

  • 김진산;성인하;김대은
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.603-607
    • /
    • 2002
  • Recently, the need leer transporting and manipulating minute amount of fluids in microscale channels (so-called micro-fluidics) has been increasing, especially in biotechnology and biochemical processing. This work demonstrates that the mechano-chemical process which consists of mechanical abrasive action combined with chemical process can be used to fabricate micro-fluidic channels more rapidly and cost effectively than other methods. In this work, capillary filling of fluids in micro-channels was investigated by theoretical approaches and experiments. From the experimental results, it is expected that a complex micro-fluidic system can be fabricated using the micro- fabrication technique and microsystem packaging method described in this work.

  • PDF

유연하고 신속한 표면미세가공기술을 이용한 Micro-fluidic Channel 제작 (Fabrication of Micro-fluidic Channels using a Flexible and Rapid Surface Micro-machining Technique)

  • 김진산;성인하;김대은
    • 한국공작기계학회논문집
    • /
    • 제11권4호
    • /
    • pp.97-101
    • /
    • 2002
  • Recently, the need for transporting and manipulating minute amount of fluids in microscale channels (so-called micro-fluidics) has been increasing, especially in biotechnology and biochemical processing. This work demonstrates that the so-called mechano-chemical process which consists of mechanical abrasive action combined with chemical process can be used to f뮤ricate micro-fluidic channels more rapidly and cost effectively than other methods. In this work, capillary filling of fluids in micro-channels was investigated by theoretical approaches and experiments. From the experimental results, it is expected that a complex micro-fluidic system can be fabricated using the micro-fabrication technique and microsystem packaging method described in this work.