• 제목/요약/키워드: File length

검색결과 146건 처리시간 0.037초

Comparison of vibration characteristics of file systems for root canal shaping according to file length

  • Seong-Jun Park;Se-Hee Park ;Kyung-Mo Cho ;Hyo-Jin Ji ;Eun-Hye Lee ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • 제45권4호
    • /
    • pp.51.1-51.10
    • /
    • 2020
  • Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

File Modification Pattern Detection Mechanism Using File Similarity Information

  • Jung, Ho-Min;Ko, Yong-Woong
    • International journal of advanced smart convergence
    • /
    • 제1권1호
    • /
    • pp.34-37
    • /
    • 2012
  • In a storage system, the performance of data deduplication can be increased if we consider the file modification pattern. For example, if a file is modified at the end of file region then fixed-length chunking algorithm superior to variable-length chunking. Therefore, it is important to predict in which location of a file is modified between files. In this paper, the essential idea is to exploit an efficient file pattern checking scheme that can be used for data deduplication system. The file modification pattern can be used for elaborating data deduplication system for selecting deduplication algorithm. Experiment result shows that the proposed system can predict file modification region with high probability.

기계적 협착부를 갖는 근관에서 Root-ZX의 정확도에 관한 연구 (A STUDY ON THE ACCURACY OF THE ROOT-ZX IN THE CANAL WITH MECHANICALLY FORMED CONSTRICTION)

  • 김병현;이영규;김용식
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.628-632
    • /
    • 1999
  • Currently electronic apex locators have been widely used to determine working length in endodontic treatment. According to Manufacture's recommendation, it is beneficial to find the working length before instrumenting the canal. However, in crown-down pressureless technique, working length of tooth is established following coronal instrumentation 3mm short of radiographic apex. In narrow canals, mechanically formed constriction might be established by coronal instrumentation in some distance from anatomical constriction. The purpose of this study was to evaluate the accuracy of Root-ZX in the canal with mechanical constriction following considerable coronal enlargement with ProFile .06 series. The 40 root canals in 30 extracted mandibular molars were accessed, and their actual length (AL) established by passing a size 10 file just through the minor apical foramen. The teeth were then embedded in an acrylic container with normal saline. The initial canal length(IL) was measured with Root-ZX by negotiating a size 10 file to the apical constriction. The canal was sequentially enlarged to size 40 with ProFile .06 file 3mm short of actual length. The enlarged final canal lengths (FL) were obtained with a size 15 file. The average values of IL, FL were calculated and compared using Repeated measures Analysis of Variance followed Turkey's Studentized Range test. The results were obtained as follows: 1. The initial canal length was 0.12mm shorter than actual canal length(P>0.05). 2. The differences between initial canal length and final canal length were not significant(P>0.05). 3. As a result of this study, regardless of mechanically formed constriction. Root-ZX differentiated between mechanical and anatomic constriction.

  • PDF

위성과 지상회선에서 파일전송을 위한 확장된 SARA 모델 시뮬레이터 구성 (Construction of a Simulator by Expanded SARA Model for File Transfer via Satellite and Terrestrial Links)

  • 박진양
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권2호
    • /
    • pp.131-140
    • /
    • 2001
  • 본 논문은 지상회선과 위성회선의 파일 전송을 위하여 CSDN 접속의 지상회선 모델인 SARA(System ARchitec’ Apprentice)모델에 위성회선을 추가하여 확장된 시뮬레이터를 제안하고 두 회선의 파일전송 효율에 대하여 해석하였다. 위성전송에서 파일전송의 효율을 평가하기 위하여 해석적 방법과 제안된 시뮬레이터로서 파일전송의 시뮬레이션을 수행하였다. 이때 적용된 전송파라미터는 단위 메시지 길이와 파일의 전송시간, 체인 레코드 수와 전송시간으로 하여 위성회선의 최적 메시지 길이를 평가하였다. 평가 결과는 위성회선에서 단위 메시지 길이를 512바이트 보다 짧게 하면 파일 전송시간은 극단적으로 길게 되며,1024바이트로 했을 때 최소로 되고 2048바이트부터 급격하게 증가되었다. 이 결과에서 최적 단위 메시지길이는 1024바이트 부근이라는 것을 확인할 수 있었다.

  • PDF

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

만곡근관에서 근관형성법에 따른 근관작업장의 변화 (Change of working length in curved canals by various instrumentation techniques)

  • 조정임;진명욱;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제31권1호
    • /
    • pp.30-35
    • /
    • 2006
  • 만곡근관에서 근관형성방법에 따른 근관작업장 변화를 평가하기 위하여 발거된 대구치의 협측 또는 근심 근관 40개에서 스테인레스-스틸 수동 파일 ($MANI^{(R)}$, 일본), 니켈-티타늄 수동 파일 (Naviflex $NT^{TM}$, 미국), ProFile, 또는 $ProTaper^{TM}$ (Dentsply-Maillefor, 스위스)를 사용하여 crown-down 방법으로 30번 크기까지 근관을 형성하고 근관형성 전후의 근관작업장 및 만곡도의 변화를 관찰하였다. 근단공에 대한 10-K파일 끝의 위치변화를 AutoCAD2000 (Autodesk 사, 미국)으로 측정하고 일원변량분석법 및 Tukey's studentized range test로 통계 분석하였다. 모든 군에서 근관형성후 근관장 및 만곡도가 유의하게 감소하였으며, 치관부 근관형성시 Gates Glidden bur를 사용한 수동파일 군이 ProFile 군보다 유의하게 많은 근관장 감소를 초래하였고, 치관부 및 근단부 전체 근관형성후에는 스테인레스 스틸 수동파일 군이 ProFile 군에서보다 유의하게 많은 근관장 감소를 나타내었다 (p<0.05).

GT Rotary Ni-Ti file과 함께 사용한 구동용 Ni-Ti file의 근관 성형력 비교에 대한 연구 (Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file)

  • 신동렬;박상진;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.196-206
    • /
    • 2002
  • 본 연구는 근관의 치관부는 GT Rotary file을 이용하여 성형하고, 근단부는 K-Flexofile, ProFile .04, Lightspeed, HERO642 file로 성형하여 근관용 file의 근관성형력을 비교하는 것이다. 실험 표본으로는 resin simulated root canal blocks(Dentsply, Swiss)를 이용하였고 4개의 군으로 분류하여 실험을 실시하였다. 모든 resin block을 GT Rotary file(Dentsply, Swiss)을 이용하여 치관부를 형성한 후 근단부는 K-Flexofile(Dentsply, Swiss), ProFile .04 taper file(Denstply. Swiss), Lightspeed file(Lightspeed Tech., USA), HERO642 file(Micromega, France)로 ISO size #35까지 형성하였다. 성형 후 preparation time과 instrument failure를 측정하였고 최종 사용한 file을 resin block 내에 재위치시켜 working length의 변화량을 0.5mm 단위로 측정하였다. Resin debris에 의한 canal blockage를 조사하였으며, 근관 내의 인상을 채득하여 canal form을 평가하였다. 성형 전과 성형 후의 사진을 촬영하고 computer software를 이용하여 중첩시킨 후 canal aberration, canal transportation을 평가하여 다음과 같은 결과를 얻었다. 1. Preparation time, working length의 변화량, canal blockage, canal aberration, canal transportation에 있어서 Ni-Ti file이 stainless steel file에 비하여 우수하였다(p<0.05). 반면에 근관성형력에 있어서 canal form과 canal transportation을 제외하고는 세 Ni-Ti file 사이에는 유의차가 없었다(p>0.05). 2. Canal form 중 taper에 있어서 Lightspeed는 적절하지 못한 taper를 보여주었다(p<0.05). 3. Canal transportation에 있어서 Lightspeed 군과 HER0642 군이 K-Flexofile 군과 ProFile .04 군에 비해 적게 나타났고(p<0.05), 특히 만곡의 끝 부분에서는 Lightspeed 군이 가장 적게 나타났다(p<0.05). 이상과 같은 연구결과로 보아 부적절한 taper를 지니고 있던 Lightspeed fie과 HERO642 file 중 HERO642 file은 GT Rotary file과 함께 사용함으로써 적절한 taper로 형성할 수 있었으나 Lightspeed file은 효과적이지 못하였으므로 적절한 taper를 형성하기 위한 file이 치근의 중간부를 형성하기 위해 필요함이 확인되었다.

쾌속조형장치의 길이오차를 이용한 형상정밀도 개선에 관한 연구 (A Study on the Improvement of Form Accuracy Using the Length Strain of Rapid Prototype)

  • 김태호;박재덕;김민주;이승수;이준희;전언찬
    • 한국정밀공학회지
    • /
    • 제21권12호
    • /
    • pp.154-159
    • /
    • 2004
  • This study is aimed to diminish the errors which created during transforming from 3D shape created with CAD program to STL file formation. The length strain which created on X-Y axises at STL file transforming is diminished by using the relation between common shape error and shrinkage rate. As the result of study, we have confirmed the length strain in accordance with facetres value. Also, the shape error is compensated with shrinkage rate by error of length strain. so, we could diminish to shape error by several tens micrometer.

여름철 거문도 남부해역에서 어획된 말쥐치의 체장과 체중 조성 (On the Total Length and Body Weight of the File File Fish , Navodos Modestus Caught in the Sonthern Sea Area of Komundo Is . During Summer)

  • 염말구
    • 수산해양기술연구
    • /
    • 제22권4호
    • /
    • pp.71-74
    • /
    • 1986
  • The author tried to clarify the distribution of the total length and body weight of the file h, Navodos modcstus, caught by trawl net during July, 1984 in the southern sea korea. Among the catches of five times fishing operation, 1540 individuals were randomly sampled for the measurement. The results are summarized as follows; " The distribution of total length showed bimodal type, wbich was able to analyzed into two normal distributions N(17.46, 1. 02^2) and N(22.09, 1. 77^2). And smaller group was much than older one. The age of the sample estimated from the total length distribution of. smaller group was 1. 5 to 2, and the larger group 2. 5 to 4. The relationship between the total length and the body weight can be presented as following equation: $$W=0.01726 L^{2.8507}$$ ' or $$W= 0.01109 L^{3.0}$$ or $$W= 0.01109 L^{3.0}$$.

  • PDF

Influence of operator's experience level on lifespan of the WaveOne Primary file in extracted teeth

  • Saleh, Abdulrahman Mohammed;Tavanafar, Saeid;Vakili-Gilani, Pouyan;Al Sammerraie, Noor Jamal;Rashid, Faahim
    • Restorative Dentistry and Endodontics
    • /
    • 제38권4호
    • /
    • pp.222-226
    • /
    • 2013
  • Objectives: The aim of this study was to assess the influence of operator experience level on the lifespan of the WaveOne Primary file (Dentsply Maillefer, Ballaigues, Switzerland) in extracted teeth. Materials and Methods: Moderately curved canals of extracted maxillary and mandibular molars were randomly distributed into 2 groups: experienced and inexperienced operators. Ten files were allocated to each group (n = 10). Each canal was prepared until the working length was reached, and the same file was used to prepare additional canals until it separated. The number of canals prepared before file separation was recorded. The fragment length of each file was measured, and the location of the fragment in the canal was determined. Data were statistically analysed using the independent 2-sample t-test. Results: The 2 operators prepared a total of 324 moderately curved canals of maxillary and mandibular molars. There was no significant intergroup difference in the mean number of canals prepared (p = 0.27). The average lifespan of the WaveOne Primary file was 17.1 and 15.3 canals, and the longest lifespan was 25 and 20 canals, when used by experienced and inexperienced operators, respectively. There were no statistically significant intergroup differences in separated fragment length and location. Conclusions: Within the limitations of this study, operator experience level appears to have no effect on the lifespan of the WaveOne Primary file in preparation of moderately curved canals. Single teeth with multiple canals can be prepared safely even by a novice operator by using a single file.