• Title/Summary/Keyword: Fifteen-phase

Search Result 60, Processing Time 0.032 seconds

A QUANTITATIVE ANALYSIS OF THE IN VIVO AMALGAM CORROSION PRODUCTS (Amalgam 부식산물의 정성분석에 관한 연구)

  • Lim, Byong-Mok;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.2
    • /
    • pp.1-17
    • /
    • 1991
  • The purpose of this study was to analyze the in vivo amalgam corrosion products qualitatively. 30 molars with large, intact amalgam restorations were selected. All the restorations were more than 5 years old. Twenty of the removed amalgams were embedded in acrylic resin block. The exposed surfaces of fifteen embedded amalgams were polished by amalgam polishing kit, and the rest were observed without polishing. The remaining 10 amalgams were fractured centrally and perpendiculary to the occlusal surface with a wire-cutter. After all specimens were cleaned ultrasonically in distilled water, each surface was examined under S.E.M. and E.D.A.X. (Energy Dispersive Micro X-ray Analyzer) to determine the morphology and chemical nature of the corrosion products. The following results were obtained: 1. The surfaces of the unpolished amalgam restorations were covered with thin amorphous layer of Sn-Ca-P-S complex with numerous cracks. 2. In the conventional amalgams, the major corrosion products were Sn-Cl phases however, tin oxide phases were also observed. 3. Only tin oxide phase was identified in the high copper amalgam, but it was less frequently observed than in the conventional amalgam. 4. It was easier to observe the corrosion product morphology in the fractured surfaces than in the polished ones. The morphologies of the corrosion product crystals looked like a stack of slightly bended plates in the Sn-Cl phases and polyhedra or polygonal prisms in the tin oxide phases.

  • PDF

Characterization of degradation of fish wastes using mixed microorganisms (복합미생물을 이용한 수산폐기물의 분해특성)

  • 정해윤;정해윤;김중균
    • Journal of Life Science
    • /
    • v.11 no.1
    • /
    • pp.76-82
    • /
    • 2001
  • Fifteen species of microorganisms were isolate form the intestines of fishes, fish feed, and ferment. Eleven microorganisms except HY4, HY8, HY12, and HY13 were Gram-positive, and HY1, HY2, HY3, HY5, HY6, and HY7 produced lactic acid. The species of HY1, HY2, HY3, HY4, HY5, HY6, HY13, and HY14 showed some growth in the medium containing 1% of NaCl. Except HY6, HY7, HY8, HY12 and HY5, 10 isolates had proteolytic activity, whereas only HY13 and HY14 had lipase activity. From all the results four isolates (HY3, HY4, HY13 and HY14) were chosen for the degradation of fish wastes. There was no mutual inhibition among the microorganisms, and the optimum temperature and pH for the growth of the mixed culture were found to be 3 2$\^{C}$ and 7, respectively. Under the optimum growth conditions the maximum optical density and the maximum specific growth rate were estimated to be 2.35 and {TEX}$0.46h^{-1}${/TEX}, respectively. Major microorganisms in the mixed culture at the log-phase were HY3 and HY4, which occupied 70%. The degrading efficiency of fish waste by the mixed microorganisms was 2.3 times higher, compared to control. The total amount of free amino acids in the degraded products from fish wastes was 39g/100g protein and little odor was produced by the mixed microorganisms after 48 hours.

  • PDF

A Stipulation Based Sources Insertion Multilevel Inverter (SBSIMLI) for Waning the Component Count and Separate DC Sources

  • Edwin, Jose S;Titus, S
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1519-1528
    • /
    • 2017
  • The paper proposes a well structured, component count waned single phase multilevel inverter (MLI) topology, which drives three different modules viz. Stipulation Based Sources Insertion (SBSI) module, Level Count Increasing (LCI) module and Inter-Linking H-Bridge (ILHB) module. The SBSI module confronts the number of basic sources needed in series/parallel to achieve required magnitude for any particular level. The LCI possesses an offsetting dc source and opuses to increase the number of levels and the ILHB module links the SBSI and LCI modules. A developed Hybrid Pulse Width Modulation (HPWM) strategy has PWM pulses for the switches of LCI module while the switches of the remaining two modules function at fundamental switching frequency. A fifteen level version of the proposed stipulation based sources insertion MLI (SBSIMLI) topology is simulated in MATLAB R2010a and a prototype of the similar specifications is constructed to validate the performance by experimental results. The comparison between the developed SBSIMLI topology and the competent topologies shows many interesting facts.

Change of the Maximal Isometric Contraction to the Spastic Muscle by NMES (신경근전기자극에 의한 경직근의 최대 등척성 수축력 변화)

  • Lim, Sang-Wan;Lee, Jeong-Woo;Kim, Tae-Youl;Song, Myung-Soo;Choi, Eun-Young
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.25-35
    • /
    • 2004
  • The purpose of this study was compared to MTICs(maximal tolerated isometric contraction), decrement and recovery. For this, using isokinetic exercise analysis device(Biodex Medical Systems Inc., Biodex System 3PRO, USA), low rate(20 Hz) and high rate(100 Hz) NMES(neuromuscular electrical stimulation) were applied to the quadriceps muscles of fifteen patients with spastic hemiplegia caused by lesions in the central nervous system. The results were as follows: 1. It was shown to fast decrement in the middle of phase at low rate NMES and to slow decrement of MTIC response at high rate NMES(p<.01). 2. It was shown to fast recovery at high rate NMES and to slow recovery at low rate NMES in recovery tendency of MTIC(p<.01). These conclusions suggest that NMES of high rate caused to slow fatigue and fast recovery different from low rate NMES.

  • PDF

A Comparative Study of Healthy City Project Evaluation in U.K. and Korea: Focusing on Liverpool City and Wonju City (영국과 한국의 건강도시 사업 평가방법 비교 연구: 리버풀과 원주시를 중심으로)

  • Kang, Shin Hee;Nam, Eun Woo;Moon, Ji Young
    • Korean Journal of Health Education and Promotion
    • /
    • v.30 no.2
    • /
    • pp.93-103
    • /
    • 2013
  • Objectives: This study was to compare two healthy cities, Liverpool in England and Wonju in Korea, which evaluated healthy city projects and to reorient evaluation strategy which fits into Korean Healthy cities. Methods: Comparatives analysis was used by reviewing documents, healthy city plan and evaluation report, of two cities. Results: Healthy city projects in two cities, fifteen programs were identical items among twenty-seven but there were differences in seven items for Liverpool and five items for Wonju. In Liverpool evaluation was done by a stakeholder group called Liverpool Local Involvement Network(LINK), while in Wonju by Yonsei Healthy City Research Center. The evaluation tool was two types; quantitative and qualitative analysis. Liverpool mostly used qualitative and added quantitative, vice versa in Wonju. Conclusions: Evaluation plan for Healthy city projects need to be made in the first phase of the projects, instead of in the end. Moreover, it is important to include stakeholder in conducting qualitative analysis for unquantifiable evidence of effectiveness, as well as quantitative analysis.

Two Cases of Pressure Ulcer Patients Treated with Acupuncture and Light Emitting Diode Light Therapy (침치료와 Light Enitting Diode 광선치료를 병행한 욕창 치료 2례)

  • Jo, Seoung Eun;Lee, Hyun;Hong, Seo Jin;Kang, Jae Hui
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.211-220
    • /
    • 2015
  • Objectives : We report two cases of pressure ulcer patients to show the efficacy of treatment with acupuncture and Light Enitting Diode(LED) light therapy. Methods : We treated two pressure ulcer patients with acupuncture, LED light therapy, herbal medication and with a simple dressing. LED light with up to $4J/cm^2$ of energy irradiated the pressure ulcer site once a day for fifteen minutes. All patients received acupuncture treatment and simple dressing for wound care. We measured phase change of the pressure ulcer in terms of ulcer size, The National Pressure Ulcer Advisory Panel(NPUAP) stage and with the The Pressure Ulcer Scale for Healing(PUSH) tool(3.0). Results & Conclusions : In each of the two cases, pressure ulcer size and total score of the PUSH tool decreased and NPUAP stage was improved from II to I. This shows that acupuncture treatment and LED light therapy may have a considerable effect in healing on the pressure ulcer.

Effect of Prolonged Running-induced Fatigue on Free-torque Components

  • Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the differences in FT (free-torque) components between non-fatigue and fatigue conditions induced by prolonged running. Methods: Fifteen healthy runners with no previous lower-extremity fractures ($22.0{\pm}2.1$ years of age) participated in this study. Ground reaction force data were collected for the right-stance phase for 10 strides of 5 and 125-min running periods at 1,000 Hz using an instrumented force platform (instrumented dual-belt treadmills, Bertec, USA) while the subjects ran on it. The running speed was set according to the preferences of the subjects, which were determined before the experiment. FT variables were calculated from the components of the moment and force output from the force platform. A repeated-measures one-way ANOVA was used to test for significant differences between the two conditions. The alpha level for all the statistical tests was 0.05. Results: The absolute FT at the peak braking force was significantly greater after 5 mins of running than after 125 mins of running-which was regarded as a fatigued state-but there were no significant differences in the absolute peak FT or impulse between the conditions. Conclusion: The FT variables in the fatigue condition during prolonged running hardly affect the tibial stress syndrome.

Comparative Analysis of Muscle Activities for Upper Extremity During Resistance Exercises Using Variable and Elastic Loads (가변부하 및 탄성부하를 이용한 저항성 기구 운동 시 발현되는 상지근육의 근 활동치 비교분석)

  • Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.37-44
    • /
    • 2006
  • The purposes of this study were to analyze and compare EMG activities of the pectoralis major, biceps brachii, triceps brachii, and brachioradialis muscles during biceps curls using a VRT device and an elastic tubing. Fifteen male college students were recruited as subjects and they performed 10-RM and 20-RM biceps curls. For each load and device condition, the mean and peak normalized EMG levels during different phases of a biceps curl were computed. For each load and phase, paired t-test (p.05) was used to find the significant difference between two devices. ANOVA with repeated measures was also used to find the significant difference among phases in terms of EMG values for each muscle. For each load and device condition, the peak and mean EMG levels during different phases of a biceps curl were computed The significant differences between devices were found in biceps brachii for EA, MD, LD phases, and triceps brachii muscles for all phases, respectively. However, no differences were found among phases for any muscle. This indicated that elastic band could have a similar characteristics of VRT. High antagonistic muscle activity as a function of injury prevention which found particularly in VRT device may suggest that elastic tubing can be a safer training device than VRT. This also imply that elastic tubing could be very effective as a home exercise tool for rehabilitation patients and elderly people.

Effects of Lower Rib Expansion Limitation on Maximal Respiratory Pressure and Abdominal Muscle Activity During Maximal Breathing in Healthy Subjects

  • Lee, Gyu-wan;Yoon, Tae-Lim;Lee, Young-jung;Kim, Ki-song;Yi, Chung-hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.6
    • /
    • pp.394-399
    • /
    • 2020
  • Purpose: The aim of this study was to determine the effects of lower rib cage lateral expansion limitation on the maximal inspiratory and expiratory pressures and on abdominal muscle activity during maximal respiratory breathing in healthy subjects. Methods: Fifteen healthy male subjects voluntarily participated in this cross-sectional study. During maximal breathing, maximal inspiratory and expiratory pressures were measured, and abdominal muscle activity was determined with using surface electromyography. Also, the measurement was repeated with using a non-elastic belt to the lower rib cage for limiting of lateral expansion. A Wilcoxon signed-rank test was performed for obtaining the statistical difference with a significance level of 0.05. Results: The findings of this study are as follows: 1) There were no significant differences in maximal inspiratory and expiratory pressure with and without lower rib cage lateral expansion (p>0.05), 2) There was no significant difference in abdominal muscle activity during the maximal inspiratory phase (p>0.05). However, right external oblique muscle activity decreased significantly during maximum exhalation with lower rib expansion limitation (p<0.05). Conclusion: The results of the current study indicate that a non-elastic belt was effective in decreasing right external oblique muscle activity during forced expiratory breathing in healthy subjects.

Evaluation of Results and Workloads of the Horizon Scanning of the Emerging Health Technology in Korea (국내 신개발 유망의료기술 탐색활동 결과 및 업무량 분석)

  • Joo, Yea Il;Lee, Hyeong Il;Song, Yeong Chae;Park, Joo Yeon;Shin, Ho Gyun
    • The Journal of Health Technology Assessment
    • /
    • v.6 no.2
    • /
    • pp.156-161
    • /
    • 2018
  • Objectives: To evaluate results and workloads of the horizon scanning of the emerging health technology since 2014 to 2016. Methods: In order to analyze the results of the emerging health technology, we identified the number of research procedure between 2014 and 2016. The sixteen findings were calculated annual workload by person, and categorized by medical phase, classification of disease, and healthcare technology. Results: An average of 5.67 personnel were involved over three years, assessment of each emerging healthcare technology was performed for each person of identifying 54 cases, filtering 2.4 cases, prioritizing 0.9 cases were performed. According to the mapping by healthcare technologies, nine medical devices (56.3%), six drugs (37.5%), and one material of the medical treatment (6.3%) were assessed. Among sixteen findings, fifteen cases were health technologies for treatment and only one case for diagnosis. Conclusion: Future plans of the horizon scanning of the emerging health technology is required appropriate manpower in charge each target number of assessment. And a legal basis should be provided for policy reflection rate. Furthermore, an evaluation criteria and procedures should be transparent to avoid a conflict of interest.