Voltage Control Strategy for Maximum Torque Operation of Field Oriented Induction Machine in the Field Weakening Region (전압 궤환 제어를 위한 약계자 영역에서의 벡터 제어 유도전동기의 최대 토오크 운전)

  • 김상훈;설승기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1084-1092
    • /
    • 1994
  • An induction machine can be operated in the constant power region over an extended high speed range by means of field weakening. A conventional field weakening method is to set the flux reference inversely proportional to the rotor speed. With this method, however, the machines can't yield the maximum torque over the entire high speed range. In this paper, a new field weakening method for the field oriented induction machine drive by the voltage control strategy is presented. The proposed scheme ensures not only producting the maximum torque over the entire field weakening region but also the robust control independent on machine parameters. Also the smooth transition into the field weakening operation and fast dynamic response during transient operation can be obtained. Simulation and experimental results from a 3hp laboratory induction motor drive system are done to confirm the proposed control algorithm.

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

A study on the Field Weakening Control of Induction Machine System for Parking Facilities (주차설비용 벡터제어 유도전동기 시스템의 약계자제어에 관한 연구)

  • Choi, Cheol;Lee, Sang-Hun;Kim, Byoung-Soo;Kim, Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1919-1921
    • /
    • 1998
  • In this paper, a control method for field weakening region of induction machine drive which is based on indirect field oriented control was implemented. Also, application method of direct field oriented control in the field weakening region using maximum torque control methods which is adaptable for parking facilities was studied. The implemented method which is based on direct field oriented control method ensures the full utilization of the output torque capability of the machine over the conventional 1/${\omega}_r$ method. And machine drive system can obtain the robustness to motor parameter variation.

  • PDF

Voltage Control Strategy for Maximum Torque Operation of Stator-Flux-Oriented Induction Machine Drive in the Field-Weakening Region (약계자 영역에서 유도 전동기의 고정자 자속 기준 최대 토크 운전을 위한 전압 제어 기법)

  • Kim, H.J.;Yu, J.S.;Won, C.Y.;Kim, E.J.;Jo, H.K.;Kim, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.30-32
    • /
    • 2005
  • In this paper, voltage control strategy for maximum torque operation of stator flux-oriented induction machine drive in the field-weakening region is proposed. In a conventional stator flux-oriented (SFO) induction machine drive system of the maximum torque capability cannot be obtained. The field-weakening method is used to vary the stator-flux reference in proportion to the inverse of the rotor speed. The proposed algorithm, based on the voltage control strategy, ensures the maximum torque operation over the field-weakening region. The proposed algorithm, voltage control strategy for maximum torque operation of capability, which is insensitive to the variation of machine parameters In the field-weakening region. The proposed algorithm is verified by simulation.

  • PDF

Field Weakening Control of IPMSM Based Next Generation High Speed Railway System (IPMSM이 적용된 차세대 고속전철 시스템의 약계자 제어)

  • Jin, Kang-Hwan;Yi, Du-Hee;Kim, Sung-Je;Chang, Chin-Young;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.351-357
    • /
    • 2010
  • In this paper, a vector control of the IPMSM drives for the next generation domestic high speed railway system is presented. The applied control method uses one pulse mode field weakening control in constant power region, and maximum torque control per ampere control in constant torque region considering current and voltage limits. An overmodulation control interval is inserted to improve the transient characteristics during transition period of the control modes. Simulation programs based on Matlab/Simulink are developed. Finally the designed system is verified by simulation and their characteristics are analyzed by the simulation results.

Selection of Optimal Stator Flux Reference of Stator Flux-Oriented Induction Machine Drive in Field Weakening Region (약계자영역에서 유도전동기의 고정자자속 기준 제어를 위한 최적 기준자속 선정방법)

  • Sin, Myeong-Ho;Hyeon, Dong-Seok;Jo, Sun-Bong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.494-499
    • /
    • 2000
  • In a conventional stator flux-oriented(SFO) induction machine drive system, the field weakening method is to vary flux reference in proportion to the inverse of the rotor speed. This paper investigates that maximum torque capability cannot be obtained in the conventional system and proposes a new selection method of flux reference to obtain maximum torque capability over the field weakening region by considering voltage, torque, and current limits.

  • PDF

Characteristics Analysis of V Shape Pole Changing Memory Motor using Finite Element Method (유한요소법을 이용한 V형상 극변환 메모리 모터의 특성 분석)

  • Kim, Young-Hyun;Kim, Su-Yong;Kim, Jung-Woo;Lee, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.872-877
    • /
    • 2015
  • The Permanent Magnet (PM) machine used at speed control using field-weakening control method. But the field-weakening current, which reduces the field flux for high speeds, causes significant copper and core losses. Therefore, this paper deals with the PM performance evaluations in a pole changing memory motor (PCMM). The PCMM can change the number of magnetic poles and produce two types of torque. When the motor operates with eight poles, it produces a magnetic torque at low rotational speeds. When the motor changes to four poles, it produces both magnetic torque and reluctance torque at high speeds. The paper explain the principle and basic characteristics of the motor by using a finite element method magnetic-field analysis, which consists of a PM magnetized by a pulse d-axis current of the armature winding. The results of our experiment show that the proposed motor reduces core loss by 10% and 55% under no-load and load conditions, and doubles the speed range of the motor.

The High Performance Flux Weakening Control of Interior Permanent Magnet Synchronous Motor (매입형 영구자석 동기전동기의 고성능 약계자 제어)

  • Lee, Jung-Ho;Kim, Jang-Mok;Won, Jong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.1051-1053
    • /
    • 1993
  • In this paper, the new flux weakening contol algorithm for the drive system of Interior Permanent Magnet Synchronous Motor(IPMSM) is proposed which includes the feedback of torque and current The torque error is used in order to control the current phase angle in the field weakening control. The proposed control method is compared with the stator flux oriented vector control method. Through the simulation the prominence of the proposed control method is verified.

  • PDF

Field Weakening Control of Permanent Magnet Synchronous Motor fed by Hysteresis Current Controlled PWM Inverter (히스테리시스 전류 제어형 PWM 인버터에 의한 영구자석 동기 전동기의 약계자 제어)

  • Yoon, Byung-Do;Kim, Yoon-Ho;Yang, Chun-Suk;Yoon, Myung-Kyun;Yoo, Bo-Min
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.167-170
    • /
    • 1991
  • The back e.m.f. of PMSM is increased as the speed is increased and it saturates the current regulator because it counteracts the available output voltage of the inverter. In the PM motor, however, the required armature terminal voltage can be reduced within the maximum output voltage of the inverter by field weakening control, in which the air gap flux is weakened by the d-axis armature current. In this paper, the field weakening control of the surface PMSM fed by a hysteresis current control led PWM inverter based on the microprocessor is presented. To show the validity of the proposed control method, the simulation and experimental results are provided.

  • PDF

Vector Control of an Induction Motor for the Field Weakening Region Considering the Variation of Magnetizing Inductance (자화인덕턴스 변화를 고려한 약계자 영역에서의 유도전동기 벡터제어)

  • ;李宅基
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.171-171
    • /
    • 1999
  • In case of field weakening region torque is directly affected by flux. In this region the flux reference is decreased inversely proportional to the rotor speed. As the flux is decreased the magnetizing inductance is normally increased. The increased magnetizing inductance limited voltage for controlling current. In this paper, measuring q axis voltage in field weakening region magnetizing inductance in flux calculating can be readjusted. Computer simulation and experiment results demonstrate the efficacy of the proposed method. Proposed algorithm is expected to the application of the adjustable drive system in the spinning and weaving field.