• Title/Summary/Keyword: Field-to-Lab Test

Search Result 223, Processing Time 0.031 seconds

A Study on Field-to-lab Test Method for the Safe Transport and Optimum Packaging Design of the Parcel Delivery in Korea (국내 택배화물의 안전운송 및 적정포장을 위한 Field-to-Lab 시험방법 연구)

  • Oh, Jae Young;Suh, Sang Uk;Lim, Mijin
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.2
    • /
    • pp.127-132
    • /
    • 2022
  • The growth of e-commerce market requires more delivery packagings, which protect goods from the damage factors on the delivery. In this study, we have analyzed the distribution environment data (vibration and impact) measured in previous study and compared with global standards (ISTA, ASTM), so that we developed the testing method for Field-to-Lab simulation suitable to the domestic delivery. In order to verify the efficacy of this method, we took the Field-to-Lab tests for 3 packaged products (detergents set, glass tableware set, small furniture), which has been frequent breakages or damages on the actual delivery by e-commerce order, so that we could find out the test results were similar to those of the actual delivery occasions. In addition, we could perform redesign and improvement of the parcel delivery packagings for safe transportation by taking this Field-to-Lab test repeatedly. This test methods was finally proposed to be Korean industrial standard (KS), and is expected to be useful as a designing tool for the packaging optimization between protecting goods and reducing packaging waste.

Development of a Spray-Injection Patching System and a Field Performance Evaluation of 100% RAP Asphalt Mixtures using a Rapid-Setting Polymer-Modified Asphalt Emulsion (아스팔트 긴급보수용 스프레이 패칭 장비 개발 및 현장 적용성 평가)

  • Han, Soo Hyun;Lee, Sang Yum;Rhee, Suk Keun;Kwon, Bong Ju
    • International Journal of Highway Engineering
    • /
    • v.20 no.1
    • /
    • pp.77-85
    • /
    • 2018
  • PURPOSES : The purpose of this study was to develop an urgent road-repair system and perform a field applicability test, as well as discover the optimum mix design for machine applications compared to the optimum mix design for lab applications. METHODS : According to reviews of the patent and developed equipment, self-propelled and mix-in-place equipment types are suitable for urgent pavement repair, e.g., potholes and cracks. The machine-application mix design was revised based on the optimum lab-test mix design, and the field application of a spray-injection system was performed on the job site. The mixture from the machine application and lab application was subjected to a wet-track abrasion test and a wheel-tracking test to calibrate the machine application. RESULTS and CONCLUSIONS : This study showed that the binder content could differ for the lab application and the machine application in the same setting. Based on the wet-track abrasion test result, the binder contents of the machine application exceeded the binder contents of the lab application by 1-1.5% on the same setting value. Moreover, the maximum dynamic stability value for the machine application showed 1% lower binder contents than the maximum lab-application value. Collectively, the results of the two different tests showed that the different sizes and operating methods of the machine and lab applications could affect the mix designs. Further studies will be performed to verify the bonding strength and monitor the field application.

Monitoring System for TV Advertisement Using Watermark (워터마크를 이용한 TV방송 광고모니터링 시스템)

  • Shin, Dong-Hwan;Kim, Geung-Sun;Kim, Jong-Weon;Choi, Jong-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.15-18
    • /
    • 2004
  • In this paper, it is implemented the monitoring system for TV advertisement using video watermark. The functions of an advertisement monitoring system are automatically monitoring for the time, length, and index of the on-air advertisement, saving the log data, and reporting the monitoring result. The performance of the video watermark used in this paper is tested for TV advertisement monitoring. This test includes LAB test and field test. LAB test is done in laboratory environment and field test in actually broadcasting environment. LAB test includes PSNR, distortion measure in image, and the watermark detection rate in the various attack environment such as AD/DA(analog to digital and digital to analog) conversion, noise addition, and MPEG compression The result of LAB test is good for the TV advertisement monitoring. KOBACO and SBS are participated in the field test. The watermark detection rate is 100% in both the real-time processing and the saved file processing. The average deviation of the watermark detection time is 0.2 second, which is good because the permissible average error is 0.5 second.

  • PDF

A Study on the design of Video Watermarking System for TV Advertisement Monitoring (TV광고 모니터링을 위한 비디오 워터마킹 시스템의 설계에 관한 연구)

  • Shin, Dong-Hwan;Kim, Sung-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.206-213
    • /
    • 2007
  • In this paper, The monitoring system for TV advertisement is implemented using video watermark. The functions of the advertisement monitoring system are monitoring the time, length, and index of the on-air advertisement, saving the log data, and reporting the monitoring result. The performance of the video watermark used in this paper is tested for TV advertisement monitoring. This test includes LAB test and field test. LAB test is done in laboratory environment and field test in actually broadcasting environment. LAB test includes PSNR, distortion measure in image, and the watermark detection rate in the various attack environment such as AD/DA(analog to digital and digital to analog) conversion, noise addition, and MPEG compression. The result of LAB test is good for the TV advertisement monitoring. KOBACO and SBS are participated in the field test. The watermark detection rate is 100% in both the real-time processing and the saved the processing. The average deviation of the watermark detection time is 0.2 second, which is good because the permissible average error is 0.5 second.

Field Test on IEC60364-4-44 for the Application in Korean distribution system (IEC60364-4-44의 국내 배전계통 적용을 위한 실증시험)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.486-487
    • /
    • 2006
  • The authors have studied on the application of IEC 60364-4-44 to Korean electrical installations of buildings from 2004 sponsored by Korean ministry of commerce, industry and energy and the test field is established in K.E.R.I. (Korea Electrotechnology Research Institute). This paper presents the summary results of establishment of test field and analysis for the application of IEC 60364 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use and production of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, since Korean electric power distribution system is based on multi-grounding system different from European system, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a Korean standard. This paper presents the establishment of test field to get background data to introduce the IEC 60364-4-44 and to evaluate the standard is applicable to domestic rule for the protection against ground fault through the related test

  • PDF

Reduction of Soil Loss from Sloped Agricultural Field by using Organic Compost (유기퇴비를 이용한 급경사 농경지 토양유실 저감)

  • Koh, Il-Ha;Kang, Hui-Cheon;Kwon, Yo Seb;Yu, Chan;Jeong, Mun-Ho;Ji, Won Hyun
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.4
    • /
    • pp.48-57
    • /
    • 2020
  • The objective of this study was to investigate the feasibility of organic compost for reducing soil loss in 25% sloped farm land. For the study, laboratory and field experiment were performed. After nine weeks monitoring in pot test, hardness of the amended soil with organic compost (1%~3%, w/w) showed two times higher than the control soil. Furthermore, soil loss of that was decreased by 95% under rainfall simulation test. From the result of laboratory experiment, organic compost with 2% (w/w) was applied for field experimental plot. After six month from April to September, the amount of soil loss became 67% of the initial, and the growth of natural vegetation was not hampered. Therefore, organic compost can be used as amendment materials to reduce soil loss in sloped farmland.

Advanced SIL(A-SIL) system for Near Field Recording (A-SIL 을 이용한 근접장 저장)

  • Han, I.G.;Shin, Y.S.;Park, J.M.;Lee, J.U.;Seo, J.K.;Choi, I.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1028-1030
    • /
    • 2007
  • Mutual compensating concept between SIL(Solid Immersion Lens) and OL(Objective Lens) of NFR(Near Field Recording) is proposed, designed and manufactured to achieve a high NA and obtain a wider manufacturing tolerance. Tolerance information is present in article. An effective NA of Advanced SIL is 1.7 and adjustment between OL and SIL is carried out using our interferometer. We measured very clear RF signal using 3-axis actuator at Test bed.

  • PDF

Configuration of Test Field for Introduction of IEC 60364-4-44 to Domestic System (IEC 60364-4-44의 국내 도입을 위한 실증시험장 구성)

  • Nam, Kee-Young;Choi, Sang-Bong;Jeong, Seong-Whan;Lee, Jae-Duck;Ryoo, Hee-Suk;Kim, Dae-Kyeong;Jung, Dong-Hak
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.731-732
    • /
    • 2007
  • This paper presents the final configuration of test field and test items for the application of IEC 60364-4-44 in Korea. IEC 60364-4-44 provides rules for the protection against the effects of conducted and radiated disturbances on electrical installations. Especially this standard deals with the protection of low voltage facility against the ground fault in the high voltage side of power distribution system. Many countries define the regulations on the use of electrical facilities based on their own power system and technical references which are considered to be suitable for them. The background of circuit of IEC 60364-4-44 is based on the ungrounded system as most of European countries. However, domestic electric power distribution system is based on multi-grounding system different from European system. Therefore, it is necessary to evaluate or prove the effect of the IEC 60364-4-44 for introducing and applying it to the domestic grounding system as a national standard. The authors with KEA(Korea Electric Association) carried out a project on the application of IEC 60364-4-44 to Korean electrical installations of buildings sponsored by Korean ministry of commerce, industry and energy for three years(2004.4.1$\sim$2007.3.31). The test field is established in K.E.R.I.(Korea Electrotechnology Research Institute), which is the purpose of evaluating the formula to calculate touch voltage and stress voltage in the IEC standards. This paper presents some considerations and final configuration of test field to evaluate and introduce the IEC 60364-4-44 applicable to domestic rule for the protection against ground fault.

  • PDF

Radar system performance test and Ana lysisusing the Radar Simulative Test & Evaluation Laboratory (레이다 원전계/모의성능 실험실을 이용한 레이다 체계성능 시험 및 분석)

  • Kim, Woo-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1138-1143
    • /
    • 2011
  • One of the critical items in radar testing is the ability to evaluate the performance of radar systems under real operational environments. But it takes lots of time and cost to operate real targets and analyze the test results due to a large amount of data based on these complicated environments. In this paper, the Radar Simulative T&E Lab. is introduced, and the test and analysis results of the developing radar for predicting the radar system performance are described in the Radar Simulative T&E Lab. This laboratory could be used to test the far-field characteristics of antenna radiation pattern and to perform an effective radar system test and evaluation using a simulative target generator under a low cost repeating test situation.

Evaluation on bridge dynamic properties and VIV performance based on wind tunnel test and field measurement

  • Yang, Yongxin;Ma, Tingting;Ge, Yaojun
    • Wind and Structures
    • /
    • v.20 no.6
    • /
    • pp.719-737
    • /
    • 2015
  • Full scale measurement on the structural dynamic characteristics and Vortex-induced Vibrations (VIV) of a long-span suspension bridge with a central span of 1650 m were conducted. Different Finite Element (FE) modeling principles for the separated twin-box girder were compared and evaluated with the field vibration test results, and the double-spine model was determined to be the best simulation model, but certain modification still needs to be made which will affect the basic modeling parameters and the dynamic response prediction values of corresponding wind tunnel tests. Based on the FE modal analysis results, small-scaled and large-scaled sectional model tests were both carried out to investigate the VIV responses, and probable Reynolds Number effects or scale effect on VIV responses were presented. Based on the observed VIV modes in the field measurement, the VIV results obtained from sectional model tests were converted into those of the three-dimensional (3D) full-scale bridge and subsequently compared with field measurement results. It is indicated that the large-scaled sectional model test can probably provide a reasonable and effective prediction on VIV response.