• 제목/요약/키워드: Field-in-Field technique

검색결과 4,922건 처리시간 0.045초

Non-Gaussian approach for equivalent static wind loads from wind tunnel measurements

  • Kassir, Wafaa;Soize, Christian;Heck, Jean-Vivien;De Oliveira, Fabrice
    • Wind and Structures
    • /
    • 제25권6호
    • /
    • pp.589-608
    • /
    • 2017
  • A novel probabilistic approach is presented for estimating the equivalent static wind loads that produce a static response of the structure, which is "equivalent" in a probabilistic sense, to the extreme dynamic responses due to the unsteady pressure random field induced by the wind. This approach has especially been developed for complex structures (such as stadium roofs) for which the unsteady pressure field is measured in a boundary layer wind tunnel with a turbulent incident flow. The proposed method deals with the non-Gaussian nature of the unsteady pressure random field and presents a model that yields a good representation of both the quasi-static part and the dynamical part of the structural responses. The proposed approach is experimentally validated with a relatively simple application and is then applied to a stadium roof structure for which experimental measurements of unsteady pressures have been performed in boundary layer wind tunnel.

Tourniquet-Free Hand Surgery Using the One-per-Mil Tumescent Technique

  • Prasetyono, Theddeus O.H.
    • Archives of Plastic Surgery
    • /
    • 제40권2호
    • /
    • pp.129-133
    • /
    • 2013
  • Background A pneumatic tourniquet is generally used to achieve a bloodless operation field in hand surgery. However, this has changed with tumescent solution-based wide-awake surgery. This study is a preliminary prospective case series study to elaborate the formula and indications of the tumescent technique in hand surgery without a tourniquet. Methods Seven patients (age range, 4 months to 37 years) underwent hand or upper extremity surgery for conditions such as nerve palsy, electric burn defect, fingertip injury, contracture, constriction ring syndrome, or acrosyndactyly. A "one-per-mil" tumescent solution (epinephrine 1:1,000,000+20 mg lidocaine/50 mL saline) was used to create a bloodless operating field without a tourniquet. Observation was performed to document the amount of solution injected, the operation field clarity, and the postoperative pain. Results The "one per mil" epinephrine solution showed an effective hemostatic effect. The tumescent technique resulted in an almost bloodless operation field in the tendon and in the constriction ring syndrome surgeries, minimal bleeding in the flap and contracture release surgeries, and acceptable bleeding in acrosyndactyly surgery. The amount of solution injected ranged from 5.3 to 60 mL. No patient expressed significant postoperative pain. Flap surgeries showed mixed results. One flap was lost, while the others survived. Conclusions Epinephrine 1:1,000,000 in saline solution is a potential replacement for a tourniquet in hand surgery. Further studies are needed to delineate its safety for flap survival.

음장의 공간적 변환기법을 이용한 타이어 구조 진동 소음 측정 (Measurement of Tire Structural Vibration Noise Using Spatial Transformation of Sound Field Technique)

  • 김병삼
    • 한국음향학회지
    • /
    • 제14권5호
    • /
    • pp.11-19
    • /
    • 1995
  • 본 논문에서는 불규칙한 노면이 설치된 섀시 동력계(chassis dynamometer)로 부터 가진된 타이어의 구조 진동 소음을 음장의 공간적 변환기법을 이용하여 측정하였다. 음장의 공간적 변환기법은 소음원으로 부터 원거리까지의 전파를 계산하는 기법이다. 즉, 한평면의 음향 측정으로 부터 측정 평면에서 멀리 떨어지거나 더 가까운 평면에서의 음장을 표현하는 변수들인 음압, 음향 인텐시티, 입자속도 등을 계산한다. 측정 평면에서 음원쪽으로 가까운 평면의 계산은 관접음장 홀로그래피를 적용하여 계산하고 먼 쪽은 헬름흘쓰 적분식을 적용한다 측정결과로 부터 타이어 구조 진동 소음의 방사형태와 소음원의 위치를 예측하였다.

  • PDF

산화막 형성 방법에 따른 전계판 구조 탄화규소 쇼트키 다이오드의 역전압 특성 (Reverse Characteristics of Field Plate Edge Terminated SiC Schottky Diode with $SiO_2$ formed Various Methods)

  • 방욱;정희종;김남균;김상철;서길수;김형우;청콴유;김은동
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.409-412
    • /
    • 2004
  • Edge termination technique is essential fer the fabrication of high volage devices. A proper edge termination technique is also needed in the fabrication of Silicon Carbide power devices for obtaining a stable high blocking voltage properties. Among the many techniques, the field plate formation is the easiest one that can utilize it for commercial usage. The growth of thick thermal oxide is difficult for SiC, however. In this paper, 6A grade SiC schottky barrier diodes(SBD) were fabricated with field plate edge termination. The oxides which is field plate were formed various methods such as dry oxidation, 10% $N_2O$ nitrided oxidation and PECVD deposition. The reverse characteristics of the SiC SBD with various oxide field plate were investigated.

  • PDF

Data processing technique for data measured in MO image measurement system

  • Lee, Wongi;Lee, Hyoyeon;Yoo, Jaeun;Youm, Dojun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권1호
    • /
    • pp.25-28
    • /
    • 2013
  • We report processing technique in the MO image measurement system. Calibration procedure is not only considered to perpendicular field but also in-plane field. Current density and field profiles are obtained by Biot-savart law and inversion method. We show example of $(Gd,Y)_1Ba_2Cu_3O_{7-{\delta}}-BaZrO_3$ film that have tilted nano rod pinning centers about $13^{\circ}$ from the c-axis.

CANDU형 핵연료 채널 압력관에 대한 원거리장 와전류의 자계분포 특성해석(I) (A FEM Analysis of Remote Field Eddy Current Distribution to CANDU Fuel Channel Tube(I))

  • 허형;정현규;김건중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.690-692
    • /
    • 2001
  • A FEM model of the remote-field eddy current effect is presented for zirconium-2.5percent niobium(Zr-2.5%Nb) nuclear reactor pressure tubes to demonstrate the important electromagnetic field. Phenomena that describe this effect. This model is applied to evaluate the optimal operating frequency and detector position. There are many ambiguous experimental results connected with this technique. Finite element calculations can be used in the interpretation of these experimental results even though the electromagnetic fields measured in the remote-field technique are very small.

  • PDF

SSFPI 기법을 이용한 MR 뇌기능 영상 -고 속의 자화율 효과의 직접적인 측정 (SSFP Interferometry (SSFPI) Technique Applied to functional MRI - A Fast and Direct Measurement of Magnetic Susceptibility Effect)

  • 정준영
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.525-534
    • /
    • 1996
  • We have developed a fast steady state free precession interferometry (SSFPI) technique which is useful for the fMRl (functional Magnetic Resonance Imaging). As is known, SSFP sequence with a suitable adjustment of Vadient (readeut) allows us to measure precession angle 6 which in tw relates to the field inhomogeneity. Combining the two pulses (known as FID and Echo) in FADE (Fast Acquisition Double Echo) sequence, for example, one can obtain the interference term which is directly related to the precession angle It has been known that a fast high resolution magnetic field mapping is possible by use of the modified FADE sequence or SSFPI, and we have attempted to use the SSFPI technique for the susceptibility-induced fMRl. When the method is applied to the susceptibility effect based functional magnetic resonance imaging (fMRl), it was found that the direct susceptibility effect measurement was possible without perturbations such as the backgrounds and inflow effect. In this paper, simulation results and experimental results obtained with 2.0 Tesla MRI system are presented.

  • PDF

단원자 포획을 위한 원자분수 (Atomic Fountain towards a single atom trap)

  • H. S. Rawat;S. H. Kwon;Kim, J. B.;K. An
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2000년도 하계학술발표회
    • /
    • pp.74-75
    • /
    • 2000
  • The past few decades have witnessed the development of very robust technique, known as magneto-optical trap(MOT), for cooling and trapping of neutral atoms using lasers and magnetic fields. This technique can easily produce cooled atoms to a temperature range of nano-kelvin $s^{(1)}$ . These laser cooled and trapped atoms have found applications in various fields, such as ultrahigh resolution spectroscopy, precision atomic clocks, very cold atomic collision physics, Bose-Einstein Condensation, the Atom laser, etc. Particularly, a few isolated atoms of very low temperature are needed in the cavity QED studies in the optical regime. One can obtain such atoms from a MOT using the atomic fountain technique. The widely used technique for atomic fountain is, first to cool and trap the neutral atoms in MOT. And then launch them in the vertical (1, 1, 1) direction with respect to cooling beams, using moving molasses technique. Recently, this technique combined with the cavity-QED has opened an active area of basic research. This way atoms can be strongly coupled to the optical radiation in the cavity and leads to various new effects. Trapping of single atom after separating it from MOT in the high Q-optical cavity is actively initiated presentl $y^{(2.3)}$. This will help to sharpen our understanding of atom-photon interaction at quantum level and may lead to the development of single-atom laser. Our efforts to develop an $^{85}$ Rb-atomic fountain is in progress. (omitted)

  • PDF

부분적인 경사자계를 이용한 고속 자기공명 영상촬영기법 (Fast MR Imaging Technique by Using Locally-Linear Gradient Field)

  • 양윤정;이종권
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권1호
    • /
    • pp.93-98
    • /
    • 1996
  • The purpose of this paper is to propose a new localized imaging method of reduced imaging time luting a locally-linear gradient. Since most fast MR(Magnetic Resonance) imaging methods need the whole $\kappa$-space(Spatial frequency space) data corresponding to the whole imaging area, there are limitstions in reducing the minimum imaging time. The imaging method proposed in this paper uses a specially-made gradient coil generating a local ramp-shape field and uniform field outside of the imaging areal Conventional imaging sequences can be used without any RF/gradient pulse sequence modifiestions except the change in the number of encoding steps and the field of view.

  • PDF