• Title/Summary/Keyword: Field width

Search Result 1,565, Processing Time 0.029 seconds

Dosimetric Consideration of the Lung Block in the Mantle Field (Mantle Field에서 Lung Block의 선량분포 고려)

  • Yoo Myung-Jin;Sin Byung-Chul;Moon Chang-Woo;Jeung Tae-Sig;Yum Ha-Yong
    • Radiation Oncology Journal
    • /
    • v.13 no.2
    • /
    • pp.199-203
    • /
    • 1995
  • Purpose: To evaluate the dose under lung block as a function of depth and the effectiveness of a block as a function of block width. Materials and Methods : Field size of mantle field was $22.8{\times}32.4cm^2.$ Dose distribution of the mantle field was measured with two dimensional water phantom system. To analyze the effectiveness of the lung block. central axis plane, 5cm off-axis plane, and 10cm off-axis plane were studied. Results: The dose under the lung block was recorded with maximum at the depth between 5cm and 10cm. In the central axis plane, dosimetric block width was $10-15\%$ less than physical block width. In the 5cm off-axis plane, dosimetric block width was $4-9\%$ less than physical block width. In the 10cm off-axis plane, dosimetric block width was $2\%$ less than physical block width. Conclusion: Depth dependence of the dose under the lung block was founded. Also, block width dependence of the lung block was founded. To induce the accurate relation between the physical block width and the 'effective' block width, it needs more detailed understanding of the variables involved.

  • PDF

Analysis on Longitudinal Dose according to Change of Field Width (선속 폭(Field Width) 변화에 따른 종축선량 분석)

  • Jung, Won-Seok;Back, Jong-Geal;Shin, Ryung-Mi;Oh, Byung-Cheon;Jo, Jun-Young;Kim, Gi-Chul;Choi, Tae-Gu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.109-117
    • /
    • 2011
  • Purpose: To analyze the accuracy of tumor volume dose following field width change, to check the difference of dose change by using self-made moving car, and to evaluate practical delivery tumor dose when tomotherapy in the treatment of organ influenced by breathing. Materials and Methods: By using self-made moving car, the difference of longitudinal movement (0.0 cm, 1.0 cm, 1.5 cm, 2.0 cm) was applied and compared calculated dose with measured dose according to change of field width (1.05 cm, 2.50 cm, 5.02 cm) and apprehended margin of error. Then done comparative analysis in degree of photosensitivity of DQA film measured by using Gafchromic EBT film. Dose profile and Gamma histogram were used to measure degree of photosensitivity of DQA film. Results: When field width were 1.05 cm, 2.50 cm, 5.02 cm, margin of error of dose delivery coefficient was -2.00%, -0.39%, -2.55%. In dose profile of Gafchromic EBT film's analysis, the movement of moving car had greater motion toward longitudinal direction and as field width was narrower, big error increased considerably at high dose part compared to calculated dose. The more field width was narrowed, gamma index had a large considerable influence of moving at gamma histogram. Conclusion: We could check the difference of longitudinal dose of moving organ. In order to small field width and minimize organ moving due to breathing, it is thought to be needed to develop breathing control unit and fixation tool.

  • PDF

A design of multi-width HTS magnets considering both wire consumption and field homogeneity

  • Yang, Hongmin;Ahn, Minchul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.2
    • /
    • pp.24-27
    • /
    • 2021
  • This paper presents a design methodology of high-temperature superconducting (HTS) magnets. The magnet consists of several double pancake coils with a variety of wire width. This technique, named Multi-Width, is well known to make efficient use of the superconducting wire. It is common for design of high-temperature superconducting magnets to not only reduce wire consumption used, but also consider the homogeneity of the magnetic field. In this paper, we study a design method that efficiently reduces wire usage while considering magnetic field homogeneity. The design is carried out by calculating the critical current and the critical magnetic field according to the configuration of arranging the thickness of the wire to determine the number of windings. The width of wire comprising the magnet was set to 4 - 12 mm, and the number of double pancake coils was set to an even number to consist of top-down symmetry. To verify the validity of the design, we compared the progress of the design code with a complete enumeration survey. As a case study, we designed a magnet that generates a central magnetic field of 3 T or more in a 240 mm bore in diameter. Optimality can be evaluated by weighing wire consumption and field homogeneity according to the magnet's use or user preference.

Stuides on the Cutting Methods of the Self-feeding Type Combine -on the Mixed Cutting Method (1)-on the Mixed Cutting Method(I) (자탈형 콤바인의 예취작업법에 관한 연구 -혼합예취법을 중심으로 (제1보)-)

  • 최복연
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.18 no.2
    • /
    • pp.4096-4104
    • /
    • 1976
  • This experiment was carried out to investigate the efficient turning method which will be able to use every cutting methods, to calculate the width of the center field which must transpose from rotary cutting method to return cutting method, to investigate the effects of L/W and unit field on the operation efficiency. The results are summarized as follows: 1. In case of cutting in the outer field, the efficient turning method is the "$\alpha$" type turning method (half U-shaped turning method) at the first rotation, is the "$\beta$" type turning method (T-shaped turning method) at the second to fourth rotation. 2. In case of cutting in the inner field, the efficient turning method which takes the least turning time is the "a" type turning method ($\Delta$-shaped turning method). 3. The width of the center field (W') changes by the length-width ratio (L/W) and width (W), W' is 9.0m in case that L/W is 2.5 and W is 30m. 4. The larger L/W and area of unit field (A) become, the more operation efficiency (E) increases, and the limits that E is affected signicantly by L/W is 2 to 3.5 and A is within 5,000$m^2$. within 5,000$m^2$.

  • PDF

An Approach to the Design Parameter of Air-Cored Superconducting Synchronous Generator (공심형 초전도 동기발전기의 설계변수에 대한 연구)

  • Jo, Young-Sik;Hong, Jung-Pyo;Lee, Ju;Sohn, Myung-Hwan;Kwon, Young-Kil;Ryu, Kang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.101-106
    • /
    • 2001
  • Air-cored superconducting synchronous generator(ASSG) is characterized by an air-cored machine with its rotor iron and stator iron teeth removed. For this reason, in the case of the shape optimum design of ASSG, other design variables different from an iron-cored machine should be considered, which will lead to substantial improvement on the performance. The major design variables that are considered by using Three-dimensional Finite element Method(3D FEM) in this paper are : 1) field coil width, 2) axial length of magnetic shield, and 3) armature winding method. End-ring of armature winding is considered in the calculation of EMF. When it comes to field coil width, as field coil width enlarges, its effective field increases but the maximum field on the superconductor decreases. this determines the critical current density. this study presents an effective field coil width, axial length of magnetic shield, and armature winding method, and also the analysis is verified by the experimental results.

  • PDF

Lateral Far-field Characteristics of Narrow-width 850 nm High Power GaAs/AlGaAs Laser Diodes

  • Yang, Jung-Tack;Kwak, Jung-Geun;Choi, An-Sik;Kim, Tae-Kyung;Choi, Woo-Young
    • Current Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.191-195
    • /
    • 2022
  • We investigate the lateral far-field pattern characteristics, including divergence angle change and far-field pattern analysis as output power increases, of narrow-emitter-width 850 nm GaAs/AlGaAs laser diodes (LDs). Each LD has a cavity of 1200 and 1500 ㎛ and narrow emitter width of 2.4 ㎛ for the top and 4.6 ㎛ for the bottom. The threshold currents are 35 and 40 mA, and L-I kinks appear at power levels of 326 and 403 mW, respectively. The divergence angle tends to increase due to the occurrence of first-order lateral mode and the thermal lensing effect. But with the L-I kink, the divergence angle decreases and the far-field pattern becomes asymmetric. This is due to coherent superposition between the fundamental and the first-order lateral mode. We provide detailed explanations for these observations based on high-power laser diode simulation results.

A Study on Design Standard for Paddy Field Ramp (수도 포장진입로의 설계기준에 관한 연구)

  • 김병갑;이중용;신승엽;김학주;이용복
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.517-524
    • /
    • 2001
  • Steep and narrow ramp installed in the paddy field makes it difficult and sometimes dangerous to drive agricultural machines on it. Because agricultural machinery become larger and heavier, it is necessary to revise design standard for ramp to provide safe travel. This study was conducted to revise the design standard fur paddy field ramp, especially for its width and slope. A mathematical model predicting travelling path of a tractor on paddy field ramp and farm road was developed and simulated. To verify this model, field tests were carried out. The model could predict trvelling path with RMS Error of 12.5cm and 8.2cm, which were judged to be adoptable fur determining the width of paddy field ramp. By applying this model to 110ps tractor, which was assumed to be the largest tractor in Korea, width of paddy field ramp was determined as over 3.6m. The slope of paddy field ramp, which provided tractor with 10% of the total weight of the tractor and the mounted implement as reaction force at front wheel against ground was analyzed by considering weight transfer effect on a ramp. The result showed that adequate slope of paddy field ramp was 14°.

  • PDF

Analysis of Axially Displaced Ellipse Gregorian Dual Reflector Antennas (축이동 그레고리안 이중 반사경 안테나의 해석)

  • 임성빈;최경국;최학근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.11
    • /
    • pp.1161-1169
    • /
    • 2003
  • In this paper, ADE(Axially Displaced Ellipse) Gregorian dual reflector antennas, which are the special form of Gregorian dual reflector antennas, were analyzed. In the procedure of antenna analysis, the aperture field distribution was obtained by using the geometrical optics and their far-field radiation characteristics were analyzed by using the aperture field method. The analysis results such as antenna efficiency, HPBW(Half Power Beam Width), FNBW(First Null Beam Width), and FSL(First Sidelobe Level) were presented as functions of edge taper and size of main reflector and subreflector. From the results in this paper, we could confirm that ADE reflector antennas have the different radiation characteristics from the classical dual reflector antennas.

Effective Periodic Poling in Optical Fibers

  • Kim, Jong-Bae;Ju, Jung-Jin;Kim, Min-Su;Seo, Hong-Seok
    • ETRI Journal
    • /
    • v.26 no.3
    • /
    • pp.277-280
    • /
    • 2004
  • The distributions of electric field and induced second-order nonlinearity are analyzed in the periodic poling of optical fibers. A quasi-phase matching efficiency for the induced nonlinearity is calculated in terms of both the electrode separation distance between the applied voltage and generalized electrode width for the periodic poling. Our analysis of the quasi-phase matching efficiency implies that the conversion efficiency can be enhanced through adjusting the separation distance, and the electrode width can be maximized if the electrode width is optimized.

  • PDF

Double-deflector effects on a low voltage microcolumn (저전압 초소형 전자 칼럼에서 이중 편향기의 효과)

  • Jang, Won-Kweon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2628-2633
    • /
    • 2009
  • In a double deflector employed microcolumn, the variation of FOV and scan field width was investigated in mode of conversely biased double deflector to eliminate barrel distortion caused by aberration. The relationship between biased voltage of each deflector and electron emission tip voltage was studied for the maximum FOV and scan field width. The limitation and the linearity of zooming current image are also estimated as a function of electron emission tip voltage.