• 제목/요약/키워드: Field test

검색결과 9,482건 처리시간 0.036초

Analysis on electrical and thermal characteristics of MI-SS racetrack coil under conduction cooling and external magnetic field

  • Chae, Yoon Seok;Kim, Ji Hyung;Quach, Huu Luong;Lee, Sung Hoon;Kim, Ho Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권4호
    • /
    • pp.61-69
    • /
    • 2021
  • This paper presents the analysis and experiment results on the electrical and thermal characteristics of metal insulation (MI) REBCO racetrack coil, which was wound with stainless steel (SS) tape between turn-to-turn layers, under rotating magnetic field and conduction cooling system. Although the field windings of superconducting rotating machine are designed to operate on a direct current, they may be subjected to external magnetic field due to the unsynchronized armature windings during electrical or mechanical load fluctuations. The field windings show the voltage and magnetic field fluctuations and the critical current reduction when they are exposed to an external magnetic field. Moreover, the cryogenic cooling conditions are also identified as the factors that affect the electrical and thermal characteristics of the HTS coil because the characteristic resistance changes according to the cryogenic cooling conditions. Therefore, it is necessary to investigate the effect of external magnetic field on the electrical and thermal characteristics of MI-SS racetrack coil for further development reliable HTS field windings of superconducting rotating machine. First, the major components of the experiment test (i.e., HTS racetrack coil construction, armature winding of 75 kW class induction motor, and conduction cooling system) were fabricated and assembled. Then, the MI racetrack coil was performed under liquid nitrogen bath and conduction cooling conditions to estimate the key parameters (i.e., critical current, time constant, and characteristic resistance) for the test coil in the steady state operation. Further, the test coil was charged to the target value under conduction cooling of 35 K then exposed to the rotating magnetic field, which was generated by three phrase armature windings of 75 kW class induction motor, to investigate the electrical and thermal characteristics during the transient state.

고압 배전선로를 이용한 고속 전력선 통신 가입자망 구축 연구 (Field Trial of Power Line Communication Access Network over Medium Voltage Power Distribution Grid)

  • 이재조;오휘명;박영진;김관호;이대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.3040-3042
    • /
    • 2005
  • During the last several years, interest in broad-band power line communications (PLC) has been grown over medium voltage(MV) power distribution lines as well as low voltage lines. This paper introduces a medium voltage PLC test field that is set up in the suburbs of Euiwang city in Korea. This test field could be used not only for the measurement of communication channel environment but also for internet service. This paper shows the configuration of medium voltage test field with network devices like MV signal coupler and the results of channel environment like noise and impulse response. It also shows the service performance of PLC access network through network management system.

  • PDF

Nondestructive Evaluation of Railway Bridge by System Identification Using Field Vibration Measurement

  • Ho, Duc-Duy;Hong, Dong-Soo;Kim, Jeong-Tae
    • 비파괴검사학회지
    • /
    • 제30권6호
    • /
    • pp.527-538
    • /
    • 2010
  • This paper presents a nondestructive evaluation approach for system identification (SID) of real railway bridges using field vibration test results. First, a multi-phase SID scheme designed on the basis of eigenvalue sensitivity concept is presented. Next, the proposed multi-phase approach is evaluated from field vibration tests on a real railway bridge (Wondongcheon bridge) located in Yangsan, Korea. On the steel girder bridge, a few natural frequencies and mode shapes are experimentally measured under the ambient vibration condition. The corresponding modal parameters are numerically calculated from a three-dimensional finite element (FE) model established for the target bridge. Eigenvalue sensitivities are analyzed for potential model-updating parameters of the FE model. Then, structural subsystems are identified phase-by-phase using the proposed model-updating procedure. Based on model-updating results, a baseline model and a nondestructive evaluation of test bridge are identified.

수평배수재용 순환골재와 쇄석의 현장시험 (Field Test of Recycled Aggregates and Crushed Stone as Horizontal Drains)

  • 김시중;이달원
    • 한국농공학회논문집
    • /
    • 제54권1호
    • /
    • pp.39-45
    • /
    • 2012
  • In this study, field test on utilization of recycled aggregates and crushed stone as horizontal drains to use an alternative material of sand in soft ground is practiced. The settlement with time showed similarly ranged from 28.4-30.3 cm in the all horizontal materials. The excess pore water pressure of the recycled aggregates and crushed stone showed smaller than sand. The small the excess pore water pressure becomes faster the consolidation period and it can reduces the amount of residual settlement. Therefore, it was verified as having enough to an alternative materials that the field applicability is excellent. The distribution of earth pressure with time showed similarly in the all horizontal materials. The recycled aggregates and crushed stone was very applicable to practice because there is no mat resistance in the horizontal drains layer. The penetration rate in the SCP and PVD improvement sections did not show large differences as the grain size and the horizontal drainage height increases.

현장조사에 의한 국내 해안 폐기물 매립장의 침출수 거동과 수리특성 (Leachate Behavior and Hydraulic Property of Domestic Seashore Landfill From Field Investigation)

  • 장연수;조용주
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.32-37
    • /
    • 1998
  • In this paper, the role of intermediate cover soils with respect to the leachate and gas flow is investigated from various field investigations and the hydraulic conductivity of the disposed waste is obtained using pumping and slug tests. From the results of field investigations, it was found that the flow of leachate and gas is prevented by the buried cover soils. The hydraulic conductivities of field pumping test and slug tests are well matched and stayed in the range of hydraulic conductivities of well compacted wastes in the literature.

  • PDF

부산석회 재활용 부지에 대한 지지력 및 환경영향 평가에 관한 연구 (Bearing Capacity and Environmental Assessment on Ground with By-product Lime)

  • 정하익;홍승서;이용수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.897-903
    • /
    • 2004
  • Waste lime used in this study is producted as a by-product in the manufacturing process of making $Na_2CO_3$ from local chemical factory in Incheon. Currently about 320 millon tons of waste lime are accumulated and annually 100,000 tons are producted. Reuse of waste lime mixed with soil for banking and backfill materia in civil works was analysed in this study. This study was Carried out to investigate the geotechnical and environmental characteristics on field application. Field investigations were conducted on the road construction site in Incheon. This study presents the results of the engineering characteristics in field test and the leaching characteristic of waste lime in laboratory column tests. Countermeasure for reduction of environmental effects was suggested from the test results.

  • PDF

SMD Inductor Core의 전기적 특성 (The Characteristics of SMD Inductor Core)

  • 오용철;김진사;이동규;신철기;김기준;이철환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2005
  • In this study, it analysis electric field of SMD(Surface Mounted Device) Inductor Core and it get electric field only exist inside of SMD core. Therefore electric fields do not affect any device and equipments. These results are very important to design data acquisition system(several test equipments such as temperature, impedance, and current test), because data acquisition system can place under the SND Inductor core. So, it can be decrease their test error due to electric field.

  • PDF

현장계측을 통한 교량상 분기기 축력 분석에 관한 연구 (Analysis of the axial force in CWR connected with turnout by means of the field measurement)

  • 최진유;김인재;황성호;양신추
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.1289-1292
    • /
    • 2006
  • The demand on a turnout layed on a bridge is rising owing to the increasing number of stations on the viaduct. And also the demand on a turnout with CWR is rising to upgrade running speed of the passing train. A CWR connected with turnout is subjected to additional axial force induced by the actions due to change in temperature, braking and starting force, and bending of the deck. But magnitude and distribution of the axial force in rails of turnout is not clear yet. So, in this study, a field measurement was conducted to know them. The strain gage method was adopted for field test. The FBG sensor for the strain measurement was used to ensure stability of test value and durability of gage for long term. It is expected that we can get data on the axial force in rail connected with turnout with respect to seasonal temperature change by the established field test system.

  • PDF

2개의 AMR 센서를 이용한 무선 차량 검지기에 대한 현장시험 및 평가 (Field Test and Evaluation for a Wireless Vehicle Detector with Two Anisotropic Magneto-Resistive Sensors)

  • 강문호
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.600-605
    • /
    • 2011
  • This paper shows field test and evaluation results for a wireless vehicle detector with anisotropic magneto-resistive (AMR) sensors. The detector consists of two AMR sensors and mechanical and electronic apparatuses. The AMR sensor senses disturbance of the earth magnetic field caused by a vehicle moving over the sensor and then produces an output indicative of the moving vehicle. In this paper, vehicle speeds are calculated by using two AMR sensors fixed on a board, with constant distance. To test and evaluate the accuracy of the detector in real traffic situations, the detector was installed on a local highway and vehicle speeds and volumes were measured both in a free running and a highly congested traffic. The measurements from the detector are compared with the reference measurements obtained from a traffic camera with the Mean Absolute Percentage Errors (MAPE), which has proved the usefulness of the detector in the field.

전자파 방사 내성 시험을 위한 최적화된 균일장 측정 방법에 관한 연구 (A Study on the Optimized Measurements of Field Uniformity for Electromagnetic Radiated Immunity Test System)

  • 조진영;문준철;정창규
    • 한국전자파학회논문지
    • /
    • 제16권6호
    • /
    • pp.622-631
    • /
    • 2005
  • 본 논문에서는 전자파 방사 내성 시험의 불확실성 요인이 되는 '오버 및 언더 편차'와 그로 인해 발생하는 '오버 및 언더 테스팅'을 줄이고자 기존 균일장 측정 방법의 문제점을 비교 분석하고 '오버 및 언더 편차'를 최소화할 수 있는 새로운 균일장 측정 방법을 제안하였다. 성능이 다른 4개의 국내 시험 기관 무반사실에 이를 적용하여 기존 측정 방법과 비교 실험하였으며 6 dB을 초과하는 필드에 대해 최소 편차인 FDI(Field Deviation Index)와 비교 분석하였다. 실험에 대한 분석 결과 '오버 및 언더 편차'는 제안 방법이 FDI와 동일하게 나타났으며 특정 주파수에선 현재 국내 규격 및 국제 규격보다 4.9 dB, 2.37 dB 개선되었고 전체 주파수에서는 평균적으로 1.193 dB, 0.017 dB 개선되었다. '오버 및 언더 테스팅 포인트'는 제안 방법이 기존 방법보다 최대 926개, 10개 포인트가 적게 측정되었으며 균일 영역 중심부 4포인트에서는 최대 118개, 9개 적게 측정되었으며, 다른 포인트에 대한 비율 또한 가장 낮게 측정되어 시험의 불확실성의 요인을 최소화하였음을 확인하였다.