• Title/Summary/Keyword: Field strength

Search Result 3,465, Processing Time 0.033 seconds

A Study on Field Test of High-Strength Shotcrete using High-quality Additions and Accelerators (고품질 혼화재와 급결제를 적용한 고강도 숏크리트의 현장실험 연구)

  • Ma, Sang-Joon;Kim, Dong-Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.121-131
    • /
    • 2006
  • The strength standard of shotcrete in Korea is relatively lower than that in Europe where high-strength shotcrete has been developed and actively applied to the common practice, so it is hard to test a quality of high-strength shotcrete. In this study, field test was performed to find a solution improving the strength and a long-term durability on domestic shotcrete. In field test, a high-strength shotcrete was produced using high-quality additions and accelerators, and an effect of additions and accelerators was observed. In addition, quality test based on EFNARC was also performed. As a result of field test, a promotion ratio of early strength is 90~97% in case of using alkali-free accelerators, therefore, alkali-free accelerators had an effect on an increase of early strength on shotcrete. A compressive strength of shotcrete using Micro-silica fume was 45.2~55.8MPa and flexible strength was 5.01~6.66MPa, so a promotion ratio of strength was 37~79%, 17~61% respectively. It was showed that increment effect of strength by the silica fume replacement of 7.5~10% for cement mass was remarkable. As a result of test, it was possible to apply high-strength shotcrete to the domestic practice using high-quality additions such as Micro-silica fume and accelerators such as alkali-free.

Physical Properties of 50MPa and 80MPa Ternary High Strength Concretes before and after Concrete Pumping

  • Lee, Bum-Sik;Kim, Seong-Deok;Jun, Myoung-Hoon;Park, Sung-Sik;Park, Su-Hee;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.451-459
    • /
    • 2012
  • At the Korea Land and Housing Corporation(LH), concretes with high design strength of 50 MPa and 80 MPa that are composed only of ordinary Portland cement, blast furnace slag, and fly ash are developed. To determine whether the developed high strength concretes have the same properties when they are produced in batch plant(B/P) condition in the ready mixed concrete plant, and as existing high strength concretes, field tests are performed and material properties are evaluated. To investigate the material properties of the high strength concretes before and after pumping, compressive strength, flowability, air content, hydration temperature, pumping and compactability are evaluated. In field tests, before and after pumping, flowability satisfied the relevant criteria. In terms of air content, while it was slightly decreased after pumping, it satisfied the requirements. Hydration temperature criteria were satisfied, and compactability was excellent as well. The study found that the developed ternary high strength concretes have the same properties as existing high strength concretes. They can also be useful for the construction of high-rise buildings, as they are economical.

On Reducing the Shadow Region for Extending the Service Area of TBN-Jeonju Broadcasting (전주교통방송 가청권 확대를 위한 음영 지역 해소 방안)

  • Kim, Tae-Hoon;Lee, Moon-Ho;Lee, Mi-Sung;Cho, Kye-Mun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1352-1370
    • /
    • 2010
  • In this paper, we investigated the shadow area of radio programs which are currently being broadcast via FM 102.5 MHz in Jeollabuk-do consisting of 6 cities and 8-guns. The field strength data of FM 102.5 MHz was used with criterion of shadow area. As a result, the field strength of the eastern mountainous area in Jeollabuk-do was very low. We also measured, compared and analyzed the field strength of 102.5 MHz(TBN-Jeonju), 100.7 MHz(KBS) and 99.1 MHz (MBC) in Jeollabuk-do. Based on the field strength data, we tried to find what correlation exists and how much influence is between difference of antenna output power and solution of shadow area. In result, enhancement of antenna output power is not solution in terms of reducing the shadow Area of 102.5 MHz(TBN-Jeonju). In addition, we measured, compared and analyzed the field strength of 102.5 MHz(TBN-Jeonju) and 106.9 MHz(EBS). In fact, the relay stations with 104.1 MHz, 104.9 MHz, 105.3 MHz and 107.5 MHz of EBS FM has a number of FM relay stations in the eastern mountainous area of Jeollabuk-do. As a result, we confirmed that EBS almost did not have shadow area in the eastern mountainous area of Jeollabuk-do based on the field strength data. As in the case of EBS and KBS, we suggest installing TBN-Jeonju FM relay station with the best solution to reducing the shadow area to extend the audible range of TBN-Jeonju.

Hysteresis-free organic field-effect transistors with ahigh dielectric strength cross-linked polyacrylate copolymer gate insulator

  • Xu, Wentao;Lim, Sang-Hoon;Rhee, Shi-Woo
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.48.1-48.1
    • /
    • 2009
  • Performance of organic field-effect transistors (OFETs) with various temperature-cured polyacrylate(PA) copolymer as a gate insulator was studied. The PA thin film, which was cured at an optimized temperature, showed high dielectric strength (>7 MV/cm), low leakage current density ($5{\times}10^{-9}\;A/cm^2$ at 1 MV/cm) and enabled negligible hysteresis in MIS capacitor and OFET. A field-effect mobility of ${\sim}0.6\;cm^2/V\;s$, on/off current ratio (Ion/Ioff) of ${\sim}10^5$ and inverse subthreshold slope (SS) as low as 1.22 V/decwere achieved. The high dielectric strength made it possible to scale down the thickness of dielectric, and low-voltage operation of -5 V was successfully realized. The chemical changes were monitored by FT-IR. The morphology and microstructure of the pentacene layer grown on PA dielectrics were also investigated and correlated with OFET device performance.

  • PDF

Triboelectrostatic Separation System for Separation of PVC and PS Materials Using Fluidized Bed Tribocharger

  • Lee, Jae-Keun;Shin, Jin-Hyouk;Hwang, Yoo-Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.10
    • /
    • pp.1336-1345
    • /
    • 2002
  • A triboelectrostatic separation system using a fluidized bed tribocharger for the removal of PVC material in the mixture of PVC/PS plastics is designed and evaluated as a function of electric field strength, air flow rate, and the mixing ratio of two-component mixed plastics. It consists of a fluidized-bed tribocharger, a separation chamber, a collection chamber and a controller. PVC and PS particles can be imparted negative and positive surface charges, respectively, due to the difference in the work function values of plastics suspended in the fluidized-bed tribocharger, and can be separated by passing them through an external electric field. Experimental results show that separation efficiency is strongly dependent on the electric Deld strength and particle mixing ratio. In the optimum conditions of 150 Ipm air flow rate and 2.6 kV/cm electric field strength a highly concentrated PVC (99.1%) can be recovered with a yield of more than 99.2% from the mixture of PVC and PS materials for a single stage of processing.

Experimental Study to Investigate the Factors Affecting Durability of Spalled Cement Concrete Pavements (스폴링이 발생한 콘크리트 포장의 내구성 영향인자 조사를 위한 실험적 연구)

  • Yoo, Tae Seok;Ryu, SungWoo;Kim, Jin Cheol
    • International Journal of Highway Engineering
    • /
    • v.20 no.2
    • /
    • pp.27-34
    • /
    • 2018
  • PURPOSES : It is necessary to prevent premature failure of concrete pavements caused by durability problems. The purpose of this study was to find factors affecting the durability of concrete pavements, and suggest improvement methods for existing concrete mix design. METHODS : Factors influencing durability were derived from laboratory test data for common field failure conditions and main properties of concrete cores taken from the field. The improvement of concrete properties was investigated by evaluating the performance of existing and proposed mix proportion designs and curing methods. RESULTS : The compressive strength and the absorbing performance of the low Blaine cement and the high-strength mixture were better than those of the Type I cement. Wet curing showed better compressive strength, elastic modulus, coefficient of thermal expansion, and absorption performance than air curing or compound curing. As a result of comparing concrete cores collected in the field, the sections with good durability showed good performance in terms of resistance to chloride ion penetration, absorption, and initial absorption rate. CONCLUSIONS : The absorption performance was considered as a possible foactor affecting durability of cement concrete pavements as a result of field core tests. In order to improve the durability of the pavement concrete, it is necessary to improve the existing mixtures and curing methods.

The Analysis for Electric Field Strength on the Ground Level from DMB Transponder in Stratosphere HAPS (성층권 고공항등체 DMB 트랜스폰더의 지표면 수신전계 강도 분석)

  • Kuk Jay-Il;Chinn Yong-Ok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.1A
    • /
    • pp.16-22
    • /
    • 2006
  • This papers described with the analysis for electric Field strength on ground level transmitted from DMB transponder in stratosphere HAPS. It is compare with horizontal propagated ground wave. Resultly we confirm the equal strength a electric field on ground level between hish altitude vertical propagated wave and horizontal ground wave, also, is only 1W compare with terrestrial facility as transmitted output power for the DMB transponder in stratosphere HAPS. It is corresponding to 1Kw as same power value in ground propagated wave. Lastly it is new material wave source and also we concluding remarks as ubiquitous communication networking media.

A Study on the Engineering Properties of Grout Materials Using a Magnetic Field Treated Water (자화수를 사용한 주입재의 공학적 특성에 관한 연구)

  • Chun, Byung-Sik;Park, Doo-Hee;Yang, Hyung-Chil;Jung, Jong-Ju;Lee, Sang-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.1195-1203
    • /
    • 2006
  • Water that is treated by passing through a magnetic field of certain strength is called Magnetic Field Treated Water(MFTW). Previous research indicate that use of MFTW can save 5% of cement dosage, decrease bleeding of concrete, and improve resistance to freezing. The reason why MFTW can improve characteristics of concrete can be explained by the molecular structure of water. Magnetic force can break apart water clusters into single molecules or smaller ones, therefore, the activity of water is improved. While hydration of cement particles is in progress, the MFTW can penetrate the core region of cement particles more easily. Hence, hydration takes place more efficiently which in turn improves concrete compressive strength. Test results demonstrate that the compressive strength of the sodium silicate cement grout homogel increases by approximately 20 - 50% by using the MFTW.

  • PDF

Factors Influencing the Background Parenchymal Enhancement in Follow-Up Breast MRI after Adjuvant Endocrine Therapy

  • Youk, Ji Hyun;Son, Eun Ju;Kim, Jeong-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.2
    • /
    • pp.99-106
    • /
    • 2015
  • Purpose: To investigate factors influencing the evaluation of background parenchymal enhancement (BPE) at follow-up breast magnetic resonance imaging (MRI) after adjuvant endocrine therapy. Materials and Methods: One hundred twelve women with breast cancer and MRI of the contralateral unaffected breast before and after endocrine therapy were identified. Two readers in consensus performed blinded side-by-side comparison of BPE (minimal, mild, moderate, and marked) before and after therapy with categorical scales. Age, body mass index, menopausal status, treatment regimen (selective estrogen receptor modulator or aromatase inhibitor), chemotherapy, follow-up duration, BPE at baseline MRI, MRI field strength before and after therapy, and recurrence were analyzed for their influences on decreased BPE. Results: Younger age, premenopausal status, treatment with selective estrogen receptor modulator, MRI field strength, and moderate or marked baseline BPE were significantly associated with decreased BPE. In multivariate analysis, MRI field strength and baseline BPE showed a significant association. Conclusion: MRI field strength and baseline BPE before and after therapy .were associated with decreased BPE at post-therapy, follow-up MRI.

Correction Methods and Validation for Environmental Conditions in the Ice Field Trials (빙해역 시운전 해석을 위한 환경조건 보정 방법 및 검증)

  • Kim, Hyun Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.2
    • /
    • pp.117-127
    • /
    • 2019
  • Vessel's ice speed performances will be verified in ice sea trial but environmental conditions of ice fields are changeable according to the weather condition of ice trial area. Speed performance has to correct in the no wind, wave and current etc. after sea trial. Especially finding ice fields which is exact the same as owner's ice thickness and strength requirements is not easy. Therefore speed correction according to environment condition has to be done after sea trial measurements. Correction methods for ice thickness, ice strength, wave, wind and ship draft, trim, ice drift etc. are checked in ice sea trial based on literature review such as ISO standard, ITTC recommendation, journal papers and proceedings of conferences. Possibility of application for current and ice drift correction in ice field are discussed and measuring schemes and procedures of correction methods are described in this paper. All of correction schemes are calculated for 'Araon' which is ice breaking research vessel with Arctic and Antarctic ice field test results. Analyzed results shows that Araon is satisfied with her official ice speed performance of 3 knots with 10MW power at 1m ice thickness, 570kPa ice flexural strength.