• 제목/요약/키워드: Field size

검색결과 4,928건 처리시간 0.028초

Performance of AMI-CORBA for Field Robot Application

  • Syahroni Nanang;Choi Jae-Weon
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.384-389
    • /
    • 2005
  • The objective on this project is to develop a cooperative Field Robot (FR), by using a customize Open Control Platform (OCP) as design and development process. An OCP is a CORBA-based solution for networked control system, which facilitates the transitioning of control designs to embedded targets. In order to achieve the cooperation surveillance system, two FRs are distributed by navigation messages (GPS and sensor data) using CORBA event-channel communication, while graphical information from IR night vision camera is distributed using CORBA Asynchronous Method Invocation (AMI). The QoS features of AMI in the network are to provide the additional delivery method for distributing an IR camera Images will be evaluate in this experiment. In this paper also presents an empirical performance evaluation from the variable chunk sizes were compared with the number of clients and message latency, some of the measurement data's are summarized in the following paragraph. In the AMI buffers size measurement, when the chuck sizes were change, the message latency is significantly change according to it frame size. The smaller frame size between 256 bytes to 512 bytes is more efficient fur the message size below 2Mbytes, but it average performance in the large of message size a bigger frame size is more efficient. For the several destination, the same experiment using 512 bytes to 2 Mbytes frame with 2 to 5 destinations are presented. For the message size bigger than 2Mbytes, the AMI are still able to meet requirement far more than 5 clients simultaneously.

  • PDF

[Retraction]Size measurement and characterization of ceria nanoparticles using asymmetrical flow field-flow fractionation (AsFlFFF)

  • Kim, Kihyun;Choi, Seong-Ho;Lee, Seungho;Kim, Woonjung
    • 분석과학
    • /
    • 제32권5호
    • /
    • pp.173-184
    • /
    • 2019
  • As the size of semiconductors becomes smaller, it is necessary to perform high precision polishing of nanoscale. Ceria, which is generally used as an abrasive, is widely used because of its uniform quality, but its stability is not high because it has a high molecular weight and causes agglomeration and rapid precipitation. Such agglomeration and precipitation causes scratches in the polishing process. Therefore, it is important to accurately analyze the size distribution of ceria particles. In this study, a study was conducted to select dispersants useful for preventing coagulation and sedimentation of ceria. First, a dispersant was synthesized and a ceria slurry was prepared. The defoamer selection experiment was performed in order to remove the air bubbles which may occur in the production of ceria slurry. Dynamic light scattering (DLS) and asymmetrical flow field-flow fractionation (AsFlFFF) were used to determine the size distribution of ceria particles in the slurry. AsFlFFF is a technique for separating nanoparticles based on sequential elution of samples as in chromatography, and is a useful technique for determining the particle size distribution of nanoparticle samples. AsFlFFF was able to confirm the presence of a little quantities of large particles in the vicinity of 300 nm, which DLS can not detect, besides the main distribution in the range of 60-80 nm. AsFlFFF showed better accuracy and precision than DLS for particle size analysis of a little quantities of large particles such as ceria slurry treated in this study.

정류기형 다이오드를 이용한 반도체 방사선 검출 장치의 제작과 그 응용에 관한 연구 (The Construction of Solid State Detector System Using Commercially Available Diode and Its Application)

  • 신동오;홍성언;이병용;이명자
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.91-95
    • /
    • 1990
  • The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy

  • PDF

휴반 살포용 노즐의 분무특성에 관한 연구 (A Study on the Characteristics of the Spraying Nozzle on Paddy Levee)

  • 최규홍;손낙율
    • 한국농공학회지
    • /
    • 제17권2호
    • /
    • pp.3758-3762
    • /
    • 1975
  • In order to find out the optimum size of nozzle of the power sprayer in the paddy field, four different sized hole of nozzles were tested on its discharge volume per unit time and its effective covering distance. 1. The discharge rate of each nozzle is proportional to square root of the transmitted internal pressure of liquid, and the discharge coefficient ranges from 0.82 to 0.86 at the pressure of 20 to 30 kg/$\textrm{cm}^2$. 2. The effective covering distance is increased as the size of the hole is larded and also the pressure is increased under under the limited pressure. Generally, the effective covering distance is not greatly increased at the pressure of above 25kg/$\textrm{cm}^2$. The distance from the nozzle to the spot where the largest amount of droplets are dropped is about 14.5m for 3.05mm nozzle and 16m for 4.05mm nozzle in the pressure range from 20 to 25kg/$\textrm{cm}^2$. 3. From the above results it is concluded that the 3mm nozzle with the power sprayers, which are now being supplied to the farmers, can be used for disease and insect control on the paddy field of which block size is 30m${\times}$100m, and operators need not to enter the field for spraying. For the 40m${\times}$100m block, 4mm nozzle should be used with large size of pump which discharge capacity is 60l/min or more.

  • PDF

INFRARED EMISSION FROM SPHERICAL DUST CLOUDS

  • Lee, Hyung-Mok;Hong, Seung-Soo;Yun, Hong-Sik;Lee, Sang-Gak
    • 천문학회지
    • /
    • 제25권2호
    • /
    • pp.111-128
    • /
    • 1992
  • Infrared emissions from spherical dust, clouds are calculated using quasi-diffusion method. We have employed graphite-silicate mixture with power-law size distribution for the dust model. The grains are assumed to be heated and cooled by radiative processes only. The primary heating source is diffuse interstellar radiation field. hut the cases with an embedded source are also considered. Since graphite grains have higher temperature than silicate grains, the observed IR emission is mainly due to graphite grains, unless the fraction of graphite grains is negligibly small. The color temperature of Bok globules obtained from IRAS 60 and $100{\mu}m$ data are found to be consistent with the dust cloud with graphite-silicate mixture exposed to average interstellar radiation field. The color temperature is sensitive to the external radiation field, but rather insensitive to the size distribution of the grains. We found that the density distribution can be recovered outside the beam size using the inversion technique that assumes negligible optical depth. However, the information within the beam size is lost for if beam convolved intensity distributions are used in deriving density profile.

  • PDF

Linear Accelerator를 이용한 Stereotactic Radiosurgery 방법 (A Method of Stereotactic Radiosurgery Using A Linear Accelerator)

  • 나수경;박재일
    • 대한방사선치료학회지
    • /
    • 제6권1호
    • /
    • pp.146-153
    • /
    • 1994
  • A modified irradiation technique utilizing a linear accelerator for radiation surgery within the brain was performed in 41 cases of patients with anteriovenous malformation(AVM), astrocytoma, meningioma. etc. The treatment planning and dosimetry of small field for stereotactic radiosurgery with 10 MV X-ray isocentically mounted linear accelerator will be presented dose with field size, the central axis persent depth dose and the combined moving beam dose distribution. The three dimensional dose planning of stereotactic focusing irradiation on small size tumor region was perfomed with dose planning computer system(Therac 2300) and was verified with film dosimetry. The more the number of strip and the wider the angle of arc rotation, the larger were the dose delivered on tumor and the less the dose to surrounding the normal tissues. In this study, the using machine and method was as fellowing. 1) Apparatus : NELAC-1018 10MV X-ray 2) Strip No. : Select the 5-7 strips 3) Cone and field size are from $1{\times}1cm^2$ to $3.5{\times}3.5cm^2$, and special circular cone designed for the purpose of minimized the risk to normal tissue and those size are $0.7{\~}3.6cm{\phi}$.

  • PDF

The Influence of the Initial Spot Size of a Double Half-Gaussian Hollow Beam on Its Propagation Characteristics in a the Turbulent Atmosphere

  • Yuan, Dong;Shu-Tao, Li;Jia-Yin, Guan;Xi-He, Zhang;Guang-Yong, Jin
    • Journal of the Optical Society of Korea
    • /
    • 제20권5호
    • /
    • pp.541-546
    • /
    • 2016
  • In this paper, by using the Rayleigh-Sommer field theory and the cross-spectral density function, the analytical expression for the intensity distribution of a double half-Gaussian hollow beam in a turbulent atmosphere is obtained. The influence of the initial spot size of this beam on its propagation properties in a turbulent atmosphere is simulated, and the intensity distributions for such beams with different spot sizes are obtained. The results show that the initial spot size has an important influence on the propagation properties in the near field, while this influence in the far field is very weak.

전자.통신 분야에서 중소기업 규모에 따른 내.외부 혁신활동이 혁신성과에 미치는 영향에 관한 연구 (The Effect of Innovation Activities on Innovation Performance according to the size of SMEs in the Field of Electronics and Communication Industry)

  • 신선아;이문수
    • 산업경영시스템학회지
    • /
    • 제37권1호
    • /
    • pp.79-90
    • /
    • 2014
  • The Purpose of this study is to empirically examine the impact of various internal and external innovation activities of SMEs on their innovation performances in the field of electronics and communication industry. Drawing upon the literature review, internal and external innovation activities are defined and conceptualized, and independent, dependent and moderator variables are developed. We have used survey-based data for this study from the survey of technology innovation activities in manufacturing industry, which was conducted by the Science and Technology Policy Institute (STEPI) in 2010. The main result of this study shows that there were no significant differences in the impact of innovation activities on market performance according to the size of SMEs. On the other hands, we found that there were significant differences in the impact of innovation activities on technological innovation performance according to the size of SMEs. Therefore, in order to make high technological innovation performance, companies in the field of electronics and communication industry need to properly implement the internal and external innovation activities by considering their size.

A Study on the Automatic Inspection System using Invariant Moments Algorithm with the Change of Size and Rotation

  • 이용중;이양범;정기화
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.479-485
    • /
    • 2004
  • The purpose of this study is to develop a practical image inspection system that could recognize it correctly, endowing flexibility to the productive field, although the same object for work will be changed in the size and rotated. In this experiment, it selected a fighter, rotating the direction from $30^{\circ}\;to\;45^{\circ}$ simultaneously while changing the size from 1/4 to 1/16, as an object inspection without using another hardware for exclusive image processing. The invariant moments, Hu has suggested, was used as feature vector moment descriptor. As a result of the experiment the image inspection system developed from this research was operated in real-time regardless of the chance of size and rotation for the object inspection, and it maintained the correspondent rates steadily above from 94% to 96%. Accordingly, it is considered as the flexibility can be considerably endowed to the factory automation when the image inspection system developed from this research is applied to the productive field.

  • PDF

Enhancement of Size Gradient of Imprinted Nanopattern by Plasma Etching under a Nonuniform Magnetic Field

  • Lim, Jonghwan;Kim, Soohyun;Kim, Da Sol;Jeong, Mira;Lee, Jae-Jong;Yun, Wan Soo
    • Applied Science and Convergence Technology
    • /
    • 제24권5호
    • /
    • pp.184-189
    • /
    • 2015
  • We report a simple way to enhance the size gradient of an imprinted nanopattern through oxygen plasma etching under a nonuniform magnetic field. A sample substrate was placed next to a magnet, and then a nonuniform magnetic field condition was formed around the sample. Using oxygen plasma etching, a line pattern having an initial width of 273 nm was gradually modified from 248 nm at one end to 182 nm at the other end. Controlling the arrangement of the magnet and sample, we could induce a triangular shape size gradient. We verified that the gradually modified nanopatterns we produced are applicable to continual optical property control, showing a possibility to be utilized for optical components such as gratings and polarizers.