• Title/Summary/Keyword: Field size

Search Result 4,928, Processing Time 0.029 seconds

Recording and Retrieving of Angular Multiplexed Near-field Holograms (근접장 홀로그램의 각도 다중화 저장 및 재생)

  • 김경염;이병호
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.60-61
    • /
    • 2001
  • We present our experimental results on the recording and retrieving of multiplexed near-field holograms using near-field scanning optical microscopy (NSOM) and a conventional rectangular-parallelepiped or cubic photorefractive crystal. Experimental results show that we can get the angular selectivity comparable with that of the volume hologram and the retrieved spot size was smaller than the Rayleigh's limit. The results also show that the angular selectivity and the retrieved spot size are strongly dependent on the recording distance between the object and the recording medium.

  • PDF

Morphometric Analyses of the Three Subspecies of Striped Field Mouse, Apodemus agrarius Pallas (Mammalia: Rodentia) from Far Eastern Asia: Taxonomic Status of North Korean Striped Field Mice (극동아시아에 서식하고 있는 등줄쥐 Apodemus agrarius Pallas (포유강 :설치 목) 3아종의 형태 형질의 분석: 북한산 등줄쥐의 분류학적 위치)

  • Koh, Hung-Sun;G. Csorba;M.P. Tiunov;G. Tikhonova
    • Animal Systematics, Evolution and Diversity
    • /
    • v.14 no.4
    • /
    • pp.327-334
    • /
    • 1998
  • Four external and 27 cranial characters of three subspecies of striped field mice (Apodemus agrarius) from 15 regions in far eastern Asia(South Korea, North Korea, northeastern China, and far eastern Russia) were analyzed by multivariate methods in order to determine taxonomic status of striped field mice from North Korea. Three subgroups were recognized: a large-size form from two localities in South Korea(Cheju Island, Wando Island): a medium-size form from eight localities in South Korea and North Korea(Jindo Island, Kunsan, Mt. Chirisan, Cheongju, Mt. Weoleksan, Mt. taebaksan; Haeju, Sineuiju); a small-size form from five localities in North Korea, northeastern China, and far eastern Russia (Mt. Kumkangsan, Mt. Myohyangsan; Jirin, Yichun; Vladivostok). It is confirmed that the large-size form, the medium-size form, and the small-size form are subspecies chejuensis, coreae, and manchuricus, respectively, as noted by Koh et al.(1997). It is revealed that striped field mice(the medium-size form) from western region of North Korea (Haeju, Sineuiju) is classified into A. agrarius coreae, as noted by Thomas(1908), but striped field mice(the small-size form) from eastern region of North Korea(Mt. Kumkangsan, Mt. Myohyangsan) is A. agrarius manchuricus.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame (핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향)

  • Lee, Jae-Bok;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.8
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

Effect of Seed Potato Size on Plug Seedling Growth and Field Performance

  • Kang, Bong-Kyoon;Kang, Young-Kil;Ko, Mi-Ra
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.46 no.2
    • /
    • pp.121-124
    • /
    • 2001
  • Potato (Solanum tuberosum L.) tubers of 10, 20, 30, 40, and 50 g were planted in plug trays with vermiculite-based root medium on 10 August 2000 and grown for 15 days in a glasshouse to determine the effects of mini-tuber size on plug seedling growth and field performance of plug seedlings. For a control, common potato tubers weighing 50 g were also planted. As size of seed tubers planted increased from 10 to 50 g, seedling height decreased from 24.6 to 20.0cm while shoot number per seedling increased from 2.0 to 3.5, main stem diameter from 4.3 to 6.1mm, and fresh weight of root + top from 9.3 to 19.4 g/seedling. At 90 days after transplanting plug seedlings, the total number of tubers per plant increased from 3.62 to 4.72, average tuber weight from 62.9 to 72.8g, and total tuber yield 20.5 to 23.6 t/ha with increase in seed tuber size. Plug seedlings raised from 50g tubers produced 22% more tubers per plant and had 21 % higher>80g tuber yield than the directly planted potatoes.

  • PDF

[Retraction]Characterization of carbon black nanoparticles using asymmetrical flow field-flow fractionation (AsFlFFF)

  • Kim, Kihyun;Lee, Seungho;Kim, Woonjung
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.77-87
    • /
    • 2019
  • High viscosity carbon black dispersions are used in various industrial fields such as color cosmetics, rubber, tire, plastic and color filter ink. However, carbon black particles are unstable to heat due to inherent characteristics, and it is very difficult to keep the quality of the product constant due to agglomeration of particles. In general, particle size analysis is performed by dynamic light scattering (DLS) during the dispersion process in order to select the optimum dispersant in the carbon black dispersion process. However, the existing low viscosity analysis provides reproducible particle distribution analysis results, but it is difficult to select the optimum dispersant because it is difficult to analyze the reproducible particle distribution at high viscosity. In this study, dynamic light scattering (DLS) and asymmetrical flow field-flow fractionation (AsFlFFF) analysis methods were compared for reproducible particle size analysis of high viscosity carbon black. First, the stability of carbon black dispersion was investigated by particle size analysis by DLS and AsFlFFF according to milling time, and the validity of analytical method for the selection of the optimum dispersant useful for carbon black dispersion was confirmed. The correlation between color and particle size of particles in high viscosity carbon black dispersion was investigated by using colorimeter. The particle size distribution from AsFlFFF was consistent with the colorimetric results. As a result, the correlation between AsFlFFF and colorimetric results confirmed the possibility of a strong analytical method for determining the appropriate dispersant and milling time in high viscosity carbon black dispersions. In addition, for nanoparticles with relatively broad particle size distributions such as carbon black, AsFlFFF has been found to provide a more accurate particle size distribution than DLS. This is because AsFlFFF, unlike DLS, can analyze each fraction by separating particles by size.

Determination of Background Gray-level for Accurate Measurement of Particles in using Image Processing Method (영상처리 기법을 이용한 입경 측정시 배경 명도가 측정 정밀도에 미치는 영향)

  • Koh, Kwang-Uoong;Lee, Sang-Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.599-607
    • /
    • 2000
  • In this study, experiments have been performed to examine the effects of background gray-level on the depth-of-field and on the in-focus criteria. The normalized value of contrast(VC) and the gradient indicator(GI) were used as the in-focus criteria for the small and the large size-ranges of particles, respectively. The slightly larger number of pixels were detected with the brighter background. The maximum of the normalized value of contrast(VCmax) is decreased with the brighter background and its deviation from that with the background gray-level of 160 turned out to be about $pm$15% when the background gray-level changes from 100 to 200. However, the maximum gradient indicator(GImax) changes with the background gray-level within only $pm$5%. The depth-of-field for the VC-applicable particle-size range is largely dependent on the background gray-level. On the other hand, the depth-of-field for the GI-applicable particle-size range changes only slightly with the background gray-level. To keep the normalized standard deviation of the particle size within 0.1, the background gray-level should be set 160$pm$20 for both the VC-applicable and GI-applicable ranges which cover the particle size between $10{\mu}m$ and $300{\mu}m$.

Self-adaptive testing to determine sample size for flash memory solutions

  • Byun, Chul-Hoon;Jeon, Chang-Kyun;Lee, Taek;In, Hoh Peter
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.6
    • /
    • pp.2139-2151
    • /
    • 2014
  • Embedded system testing, especially long-term reliability testing, of flash memory solutions such as embedded multi-media card, secure digital card and solid-state drive involves strategic decision making related to test sample size to achieve high test coverage. The test sample size is the number of flash memory devices used in a test. Earlier, there were physical limitations on the testing period and the number of test devices that could be used. Hence, decisions regarding the sample size depended on the experience of human testers owing to the absence of well-defined standards. Moreover, a lack of understanding of the importance of the sample size resulted in field defects due to unexpected user scenarios. In worst cases, users finally detected these defects after several years. In this paper, we propose that a large number of potential field defects can be detected if an adequately large test sample size is used to target weak features during long-term reliability testing of flash memory solutions. In general, a larger test sample size yields better results. However, owing to the limited availability of physical resources, there is a limit on the test sample size that can be used. In this paper, we address this problem by proposing a self-adaptive reliability testing scheme to decide the sample size for effective long-term reliability testing.

Enhanced density of optical data storage using near-field concept : Fabrication and test of nanometric aperture array (근접장을 이용한 고밀도 광 메모리에 관한 연구 : 광 픽업을 위한 미세 개구 행렬의 제작과 시험)

  • J. Cha;Park, J. H.;Kim, Myong R.;W. Jhe
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.168-169
    • /
    • 2000
  • We have tried to enhance the density of the near-field optical memory and to improve the recording/readout speed. The current optical memory has the limitation in both density and speed. This barrier due to the far-field nature can be overcome by the use of the near-field$^{(1)}$ . The optical data storage density can be increased by reducing the size of the nanometric aperture where the near-field is obtained. To fabricate the aperture in precise dimension, we applied the orientation-dependent / anisotropic etching property of crystal Si often employed in the field of MEMS$^{(2)}$ . And so we fabricated the 10$\times$10 aperture array. This array will be also the indispensable part for speeding up. One will see the possibility of the multi-tracking pickup in the phase changing type memory through this array$^{(3)}$ . This aperture array will be expected to write the bit-mark whose size is about 100nm. We will show the recent result obtained. (omitted)

  • PDF

Influences of Grain Size on some Properties of the Penferroelectric PLZT Ceramics (준강유전 PLZT 세라믹의 그레인 크기 변화에 따른 특성연구)

  • Park, Chang-Yub;Yoo, Jo-Hyn;Park, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.213-215
    • /
    • 1987
  • In this paper, influences or grain size on the electro-optic properties were studied on the penferroelectric PLZT ceramics. The specimens were fabricated by the two stage sintering method. Relative permittivity was a little increased with the increment or grain size in 9,9.5/65/35 (La/Zr/Ti) PLZT specimens, and Curie temperature was decreased in the 9.5/65/35 specimens but constant in the 9.5/65/35 specimens. As the grain size was increased, field induced polarization and dP/dE were increased. Because domain walls can be easily moved by electric field. Light transmittance was increased in the 9/65/35 PLZT specimens but there was little effect on the grain size in the 9.5/65/35 PLZT specimens.

  • PDF