• 제목/요약/키워드: Field simulation

검색결과 5,641건 처리시간 0.041초

전기철도 일형식 부하 크기에 따른 전압강하 측정 및 분석 (Test and Analysis of Voltage Drop according to Load Capacity in Traction Power Supply System)

  • 김주락;장동욱;창상훈;이영흠
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.940-947
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

승강압 쵸퍼를 이용한 새로운 발전기 여자 시스템 (A New Generator Static Excitation System Using Boost-Buck Chopper)

  • 류홍우;임익헌;설승기;박민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.426-430
    • /
    • 1996
  • A new generator excitation system using a boost-buck chopper as a kind of static exciters is proposed to overcome the lack of field forcing capability of the bus fed exciter under the Input line fault condition. It increases or maintains the generator field current by boosting the field voltage in the case of the input AC line voltage drop during and immediately after a fault. The validity of the proposed excitation system is verified with the computer simulation. The generator stability according to the each difference exciter is tested using a commercial software package-CYME. The simulation results of the stability analysis on the generator with the proposed exciter is better than that of the bus fed exciter. This boost-buck chopper exciter can be simply implemented and controlled by the modem power electronics technology.

  • PDF

연안도시지역의 대기유동장에서 대기오염물질의 확산과 이동에 관한 수치모의 (Numerical Simulation for Diffusion and Movement of Air Pollutants in Atmospheric Flow Coastal Urban Region)

  • 이화운;김유근
    • 한국환경과학회지
    • /
    • 제6권5호
    • /
    • pp.437-449
    • /
    • 1997
  • To predict diffusion and movement of k pollutants In coastal urban region a numerical simulation shouts be consider atmospheric flow field with land-sea breeze, mountain-valley wand and urban effects. In this study we used Lagrangian [article dispersion method In the atmospheric flow field of Pusan coastal region to depict diffusion and movement of the Pollutants emoted from particular sources and employed two grid system, one for large scale calculating region with the coarse mesh grid (CMG) and the other for the small region with the One mesh 914 (FMG). It was found that the dispersion pattern of the pollutants followed local circulation system in coastal urban area and wale air pollutants exhausted from Sasang moved Into Baekyang and Jang moutain, air pollutants from Janglim moved into Hwameong-dong region.

  • PDF

전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석 (Measurement and Analysis of Voltage Drop in Traction Power Supply System)

  • 김주락;이영흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

An RGB to RGBY Color Conversion Algorithm for Liquid Crystal Display Using RGW Pixel with Two-Field Sequential Driving Method

  • Hong, Sung-Jin;Kwon, Oh-Kyong
    • Journal of the Optical Society of Korea
    • /
    • 제18권6호
    • /
    • pp.777-782
    • /
    • 2014
  • This paper proposes an RGB to RGBY color conversion algorithm for liquid crystal display (LCD) using RGW pixel structure with two-field (yellow and blue) sequential driving method. The proposed algorithm preserves the hue and saturation of the original color by maintaining the RGB ratio, and it increases the luminance. The performance of the proposed RGBY conversion algorithm is verified using the MATLAB simulation with 24 images of Kodak lossless true color image suite. The simulation results of average color difference CIEDE2000 (${\delta}E^*_{00}$) and scaling factor are 0.99 and 1.89, respectively. These results indicate that the average brightness is increased 1.89 times compared to LCD using conventional RGB pixel structure, without increasing the power consumption and degrading the image quality.

A Simulation and Property Analysis according to Electromagnetic Wave Absorber Shape

  • Kwon, Seok Hun;Hwang, Hyun Suk;Kang, Hyunil
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제10권4호
    • /
    • pp.1-5
    • /
    • 2018
  • The property of magnetic field and properties of EMW(Electro Magnetic Wave) absorption with multi-shaped EMW absorber was simulated. As a magnetic field having high density was showed at bottom of EMW absorber, simulation showed that overall EMW was absorbed at the bottom of multi-shaped absorber. The absorption properties of EMW according to thickness of absorber showed that it enhanced about 50-60 percent. Also, EMW absorption properties was checked with surface area of EMW absorber. A cylinder-shaped EMW absorber exhibited good property among multi-shaped EMW absorber based on these result.

자외선.오존 살균 소독장치 제작을 위한 체시뮬레이션 및 대장균 제거 특성 (Hydraulic Simulation and Removal Characteristics of Escherichia Coli for Producing of Ultraviolet rays.Ozone Sterilization Apparatus)

  • 황인아;이현수;박재윤
    • 전기학회논문지P
    • /
    • 제54권4호
    • /
    • pp.198-202
    • /
    • 2005
  • The simulation of hydraulic pressure distribution of discharge tube with globular beads and the removal characteristics of Escherichia coli by the discharge tube with globular beads were estimated. The removal characteristic of Escherichia coli was related to the input voltage because the electric field is increased according to input voltage. As the passing amount of test water in discharge tube is increased, the removal ratio of Escherichia coli was increased because passing numbers of electric field section is increased.

실제 데이터를 이용한 태양광 발전시스템의 시뮬레이션 (A Novel Simulation Method of PV Generation System using Field Data)

  • 박민원;김봉태;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.52-54
    • /
    • 2000
  • In PV power generation system study, huge system apparatuses are needed in order to verify the effect of system efficiency and stability considering the size of solar panels, the sort of converter types, and the load conditions and so on. And also, under the same weather and load conditions it is impossible to compare a certain MPPT control scheme to others. In this paper, in order to obtain effective solutions for the above mentioned topics, the solar cell array is simulated with it's VI characteristic equations, and the real field data of weather conditions is interfaced to EMTDC using Fortran program interface method. Consequently the simulation of PV power generation system using field data is realized in this paper, and acceptable results, which show close match between the real data of PV panel and the simulated data, were obtained.

  • PDF

쇼트키 장벽 트랜지스터의 빛 조사에 따른 전기적 특성 연구 (Electric characteristics of Schottky barrier Field Effect Transistors with Halogen and Deuterium lamp)

  • 황민영;구상모
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.348-348
    • /
    • 2010
  • Nanostructures have great potential in various devices due to the their promising electronic and optical properties. Nano-patterned the front surface of a solar cell generally results in improved performance, mostly due to an increase in the short-circuit current by the incident photons strike the cell surface at an angle. In this work, we investigate AFM-assisted nano-patterned field effect transistors (FETs) with vairous silicon oxide distance value D, from ${\sim}0.5{\mu}m$ to $1{\mu}m$. Also, we compared the electro-optical characteristics of the patterned FETs and the non-patterned FETs (reference device) based on both 2-dimensional simulation and experimental results for the wavelength from 100nm to 900nm. In addition, we report electric characteristics for illuminated surface in schottky barrier field effect transistors (SB-FETs).

  • PDF

나노튜브 직경과 산화막 두께에 따른 탄소나노튜브 전계 효과 트랜지스터의 출력 특성 (Output Characteristics of Carbon-nanotube Field-effect Transistor Dependent on Nanotube Diameter and Oxide Thickness)

  • 박종면;홍신남
    • 한국전기전자재료학회논문지
    • /
    • 제26권2호
    • /
    • pp.87-91
    • /
    • 2013
  • Carbon-nanotube field-effect transistors (CNFETs) have drawn wide attention as one of the potential substitutes for metal-oxide-semiconductor field-effect transistors (MOSFETs) in the sub-10-nm era. Output characteristics of coaxially gated CNFETs were simulated using FETToy simulator to reveal the dependence of drain current on the nanotube diameter and gate oxide thickness. Nanotube diameter and gate oxide thickness employed in the simulation were 1.5, 3, and 6 nm. Simulation results show that drain current becomes large as the diameter of nanotube increases or insulator thickness decreases, and nanotube diameter affects the drain current more than the insulator thickness. An equation relating drain saturation current with nanotube diameter and insulator thickness is also proposed.