• Title/Summary/Keyword: Field protection

Search Result 1,463, Processing Time 0.032 seconds

Field Testing Center Design of Cathodic Protection System for Maritime Metallic Structures (해양구조물 전기방식시스템 현장적용실험장 설계)

  • Ha, Tae-Hyeon;Bae, Jeong-Hyo;Lee, Hyeon-Gu;Ha, Yun-Cheol;Kim, Dae-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.633-636
    • /
    • 2003
  • Most of maritime metallic structures are adopted a CP(Cathodic Protection) System for protection of corrosion in advanced country. So, we had been developed a remote corrosion monitoring control system. And we want to know the characteristics of efficiency, reliability, durability and so on. On the view point of it, we have to test in real field. in terms of design, cathodic protection systems, corrosion monitoring systems and optimal corrosion control systems compare to general commercial products. So, these systems have being studied to improve their capability. In this paper, the result of field testing center design of intelligent cathodic protection system including anodes, a real-time wireless remote corrosion monitoring and corrosion control system are described in naval ports.

  • PDF

A Study on Analysis Method of Underwater Electric Field Signature due to Ship's Corrosion and Corrosion Protection System (선체 부식 및 부식 방지장치에 의한 수중 전기장 신호 해석 방안 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Jeon, Jae-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.43-52
    • /
    • 2008
  • The galvanic corrosion of a vessel, or systems fitted to minimize the ship's corrosion such as ICCP (Impressed Current Cathodic Protection) system and sacrificial anodes, can lead to significant electrical current flow in the sea. The presence of vessel's current sources associated with corrosion will give rise to detectable electric field surrounding the vessel and can put it at risk from mine threats. For this reason, it is necessary to design corrosion protection systems so that they don't only prevent a hull corrosion but also minimize the electric field signature. In this paper, we describe theoretical backgrounds of underwater electric field signature due to corrosion and corrosion protection system on naval vessels and analysis results of the electric field according to the ship's hull and it's propeller coating damage and ICCP anode displacement.

The Effect of External DC Electric Field on the Atmospheric Corrosion Behaviour of Zinc under a Thin Electrolyte Layer

  • Liang, Qinqin;YanYang, YanYang;Zhang, Junxi;Yuan, Xujie;Chen, Qimeng
    • Corrosion Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.54-59
    • /
    • 2018
  • The effect of external DC electric field on atmospheric corrosion behavior of zinc under a thin electrolyte layer (TEL) was investigated by measuring open circuit potential (OCP), cathodic polarization curve, and electrochemical impedance spectroscopy (EIS). Results of OCP vs. time curves indicated that the application of external DC electric field resulted in a negative shift of OCP of zinc. Results of cathodic polarization curves measurement and EIS measurement showed that the reduction current of oxygen increased while charge transfer resistance ($R_{ct}$) decreased under the external DC electric field. Variation of OCP negative shift, reduction current of oxygen, and $R_{ct}$ increase with increasing of external DC electric field strength as well as the effect of external DC electric field on double-layer structure in the electrode/electrolyte interface and ions distribution in thin electrolyte layer were analyzed. All results showed that the external DC electric field could accelerate the corrosion of zinc under a thin electrolyte layer.

The Application of Standard in According to Ground and Electrical Continuity Testing of Lightning Protection Equipment in Field (피뢰설비현장의 접지 및 전기적 연속성 시험에 따른 표준적용)

  • Song, Gil-Mok;Koo, Kyung-Wan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.583-588
    • /
    • 2014
  • In this study, there are examined to the grounding of lightning protection system and electrical continuity tests in the field. The standard for lightning protection system is different design or construction according to the characteristics of the structure. Ground is measured and compared at least four locations. According to the measured results in the field, the sampled values of the ground resistance are measured $5{\Omega}$ or less and the difference between each value is suitable as $0.2{\Omega}$ or less. The values of the electrical continuity test between ground and metal bodies are measured 3 groups such as isolated portion, the mechanical contacted portion, and the electrical continuity portion measuring $0.2{\Omega}$ or less. It is measured to be less than $0.2{\Omega}$ at all in metal bodies of underground. A metal body installed inside the structure is not isolated, but the resistance values are higher than $0.2{\Omega}$. Therefore, It must be carried out the structure having lightning protection system confirm the LPL(lightning protection level) and design the strategy.

Sapstain and Mold Control on Radiata Pine Lumber: Laboratory and Field Tests of Selected Fungicides

  • Kim, Jae-Jin;Ra, Jong-Bum;Kim, Hyung-Jun;Kim, Gyu-Hyeok
    • Mycobiology
    • /
    • v.30 no.1
    • /
    • pp.37-40
    • /
    • 2002
  • The susceptibility of radiata pine sapwood to fungal attack and the ability of selected fungicides to control colonization of sapstain and mold fungi on green radiata pine sapwood were evaluated. Radiata pine sapwood was highly susceptible to fungal staining, suggesting that prompt application of fungicides after sawing is essential for preventing fungal colonization. The ability of commercial fungicides to prevent fungal discoloration on radiata pine sapwood was assessed using an accelerated 6-week test on small samples in the laboratory, and in field tests using bulk-piled boards exposed outdoors for 6 weeks during summer rainy season. In laboratory tests, Hylite extra provided excellent protection against fungal discoloration even at the lowest concentrations. Hylite clear, Britewood S, and NP-1 Plus provided good short-term protection(2 to 4 weeks), but higher chemical loadings were, required for long-term protection(6 weeks). Woodguard produced little or no protection over the test periods. In field tests, Kathon 893 provided markedly superior protection at the concentration of 0.5 percent or higher. NP-1 Plus provided relatively good protection at all concentrations evaluated. Hylite extra was effective only for short-term protection(2 to 4 weeks) at all concentrations tested, but higher solution strengths were needed for longterm protection.

A Study on Loss of Excitation Algorithm for Generator Field Protection (발전기 계자보호를 위한 계자상실 알고리즘에 관한 연구)

  • Park, Yu-Yeong;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.368-372
    • /
    • 2014
  • The most widely used scheme for detecting loss of excitation on generator is used to sense apparent impedance from generator terminals. This paper presents loss of excitation algorithm using DFT filter based negative offset mho elements for generator field protection. It's algorithm includes two negative mho characteristics looking in the generator. The generator control system was modeled by PSCAD/EMTDC software, and then the proposed algorithm was tested by the collecting relaying signals from selected the generator model. From simulation results, the loss of excitation algorithm can be used to field protection for generator.

A study on a curriculum for information protection specialty manpower training (정보보호 전문 인력 양성을 위한 교육과정 모델에 관한 연구)

  • Lee, Moon-Ku
    • Journal of the Korea Computer Industry Society
    • /
    • v.5 no.8
    • /
    • pp.811-818
    • /
    • 2004
  • The spreading of internet, combined with the computerization of industry and the life whole has created an incereased demand on the private life protection and information portection, but due to the lack of specialty manpower on the information protection industry field there are many difficulties. Therefore, in this paper a curriculum for an information protection specialty manpower training is proposed. The proposed curriculum indispensability 1,2 and classified with a selection 1,2 and classified with a selection 1,2. The information protection application field into 9 segments of domains, and to carry out the curriculum in a ring structure. The curriculum based on the information security field's 9 domains and related field practical business, and the course offered after graduation to deepen the specialty, need to be carried out by each domain in order to continuously carry out the information security deepening process.

  • PDF

Analysis of Tidal Stream around Ship Impact Protection of Incheon Bridge Using CFD (CFD를 사용한 인천대교 충돌방지공 주변의 조류 흐름장 해석)

  • Kim, Gunwoo;Oh, Sang Ho;Yi, Jin-Hak;Kwon, Ohjung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • Recently, the massive offshore bridges in a ship passage have been constructed on the sea. Therefore, the ship impact protection for the bridge-piers are installed to consider the possibility of vessel collision danger. Due to the ship impact protection, the flow-field characteristics are changed in comparison with the condition without the ship impact protection. Especially, the fluid velocity between the pier and the ship impact protection is possible to increase due to the contraction of the cross sectional area of flow. In this study, the tidal energy magnitude around the ship impact protection of Incheon bridge is assessed by simulating the flow-field by using FLOW-3D software.

  • PDF

Application of Cold Weather Concrete using Accelerator for Freeze Protection (내한촉진제를 사용한 한중콘크리트의 현장적용)

  • Park, Sang-Joon;Won, Chul;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2003.05a
    • /
    • pp.13.2-17
    • /
    • 2003
  • When fresh concrete is exposed to low temperature, the concrete may suffer frost damage due to freezing at early ages and strength development may be delayed. One of the solution methods to resolve these problems is to lower freezing temperature of concrete by the use of chemical admixture called Accelerators for Freeze Protection. In this study, it was the results of appling cold weather concrete using Accelerator for Freeze Protection in the Daewoo Trump world field. Before the application of the cold weather concrete using accelerator for freeze protection, we executed the some test in the laboratory and mock-up test in the field. We examined the manifestation of compressive strength complying with the amount of Accelerators for Freeze Protection and curing conditions, and then made a selection of most suitable amount of Accelerators for Freeze Protection.

  • PDF