• 제목/요약/키워드: Field installation test

검색결과 276건 처리시간 0.031초

송전용 애자의 인공오손시험 기법과 누설전류 특성 (Artificial contaminated test method and leakage current characteristics of EHV insulators)

  • 최인혁;정윤환;최장현;이동일
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.386-391
    • /
    • 2004
  • To find out the reason of accident by being stained of insulators, this paper researched and analyzed the result of electrical characteristic test and field test of EHV insulator through artificial contaminated method. The best way to evaluate contaminated level of insulator surface is getting a contamination data by regional groups continually. But it is needed a lot of time and manpower. To overcome those difficulties, this research introduced ESDD(equivalent salt deposit density) measurement method which is adapted to the international codes of IEC and compared the relation between experimental test results which contaminated insulators by going through stain procedure and electrical measurement results.

  • PDF

탄소섬유 보강판 전용 정착장치를 이용한 외부 프리스트레싱 보강공법 사례연구 (Case study on the external prestressing method strengthened carbon fiber reinforced plates.)

  • 정원용;임공묵
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.1003-1006
    • /
    • 2003
  • In recent years, FRP plates have been studied for flexural reinforcement of RC structures due to easy installation and good Quality control. This study presents experimental field test results for the effectiveness of flexural reinforcement of the RC slab using external prestressing with thin CFRP strips made by the pultrusion process. It was demonstrated that flexural strength was considerably increased with relatively easy installation when compared to the other methods used for the composite reinforcement.

  • PDF

초전도에너지 전송시스템에 따른 충방전 특성 (Charge-discharge properties by the superconducting energy transfer system)

  • 최효상
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.363-365
    • /
    • 2005
  • It describes a design analysis and test results of an energy transfer system which consists of two 0.5 MJ superconducting coil and three Inverter-Converter Bridges(hereinafter called ICB). A point of design is to satisfy the required stored energy capacity rather than magnetic field density with minimum energy transfer time using the calculation results of state-space averaging methods instead of Fourier series. It is proven that the considered methods are effectively through system experiments.

  • PDF

Effect of water content on near-pile silt deformation during pile driving using PIV technology

  • Jiang, Tong;Wang, Lijin;Zhang, Junran;Jia, Hang;Pan, Jishun
    • Geomechanics and Engineering
    • /
    • 제23권2호
    • /
    • pp.139-149
    • /
    • 2020
  • Piles are widely used in structural foundations of engineering projects. However, the deformation of the soil around the pile caused by driving process has an adverse effect on adjacent existing underground buildings. Many previous studies have addressed related problems in sand and saturated clay. Nevertheless, the failure mechanism of pile driving in unsaturated soil remains scarcely reported, and this issue needs to be studied. In this study, a modeling test system based on particle image velocimetry (PIV) was developed for studying deformation characteristics of pile driving in unsaturated silt with different water contents. Meanwhile, a series of direct shear tests and soil-water characteristic curve (SWCC) tests also were conducted. The test results show that the displacement field shows an apparent squeezing effect under the pile end. The installation pressure and displacement field characteristics are sensitive to the water content. The installation pressure is the largest and the total displacement field is the smallest, for specimens compacted at water content of 11.5%. These observations can be reasonably interpreted according to the relevant unsaturated silt theory derived from SWCC tests and direct shear tests. The variation characteristics of the soil displacement field reflect the macroscopic mechanical properties of the soil around the pile.

균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성 (Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields)

  • 김태기;김승민;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.

공동주택 금속기와지붕 수뢰시스템의 자재 및 시공기법 개발 (Development of Components and Installation Techniques of Air-termination System on the Metal Roof in Apartments)

  • 이기홍
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.109-115
    • /
    • 2011
  • Apartments covered with a metal roof made from galvalume steel are prevailing due to their economic and technical advantages. The metal roof, however, has disadvantages in terms of the installation of air-termination system on it because of the slip thickness of the metal roof. In this paper, the impacts of the lightning current to a metal roof were verified experimentally with a short lightning impulse current (10/350[${\mu}s$]). Also, we developed various supporters of air-termination conductor for the metal roof and verified their excellent workability and economical strength through field application test.

진공인터럽터 외부쉴드가 절연성능에 미치는 영향 분석 (An Analysis of Insulation Performance Result from Shield of Outside Vacuum interrupter)

  • 윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.100-100
    • /
    • 2010
  • Because of power consumption increase, global wanning, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. To improve the insulation performance, the high E field concentration phenomena was considered. Breakdown mechanism in vacuum is different from that in other insulation materials. therefore, It is necessary to understand the electric field distribution and insulation characteristics. This paper discusses the simulation and LI(light impulse) test of the shield of outside vacuum interrupter As a result, FEM simulation and LI test show that improve distribution of electrical field and equi-potential line. due to external shield. in this case, outside shield induced electric field of triple junction point.

  • PDF

아스팔트 콘크리트 포장 변형률계 매설 방법 개선에 관한 연구 (Improvement of Field Installation Method for Asphalt Concrete Pavement Strain Gauge)

  • 이재훈;김지원;김도형;이광호
    • 한국도로학회논문집
    • /
    • 제5권3호
    • /
    • pp.31-42
    • /
    • 2003
  • 국내의 포장 재료와 교통 및 기후조건이 반영되는 포장설계법 개발을 위한 연구가 진행중에 있으며, 이를 위해 실제 교통량 및 기후조건이 반영되고 이에 따른 포장의 거동을 모니터링 할 수 있는 대규모의 현장시험시설로 시험도로를 건설하였다. 시험도로 아스팔트 포장구간은 15개의 다양한 두께 및 재료를 가진 단면들로 구성되어 있다. 이러한 단면들을 평가하기 위해 포장체 내에 다양한 계측기들이 매설되어 있다. 계측기 매설에 있어서 핵심 요소는 매설 위치의 정확성과 장기적인 생존율 및 내구성이다. 외국의 시험사례를 보면, 이런 정확성과 내구성은 매설 방법에 크게 영향을 받는다. 이에 본 연구에서는 2000년도부터 3년여 동안 일반적인 계측기 매설 방법인 마운드, 블록아웃. 트렌치컷에 대해 시험시공을 수행하였으며 시험시공 결과를 분석하여 시험도로에 적용하였다. 위치의 정확성, 생존의 안전성, 시공성, 재료의 균질성 측면에서 시험시공 결과를 평가한 결과 블록아웃이 가장 효율적인 방법으로 나타났다. 그러나, 표층의 경우 블록아웃에 부적절한 층두께 등의 특성을 감안하여 마운드 방법을 사용하는 것으로 결정하였다. 아스팔트 기층과 중간층의 매설에는 블록아웃을, 표층의 매설에는 마운드를 사용하는 것으로 결정했다. 2003년 9월 3일부터 11월 18일까지 2달 여에 걸쳐 총 374개의 아스팔트 포장 변형률계를 시험도로에 매설하였다. 계측값 분석 결과, 마운드의 경우 6.3%, 블록아웃은 2.5%의 계측기가 매설 전후의 계측값 변화가 일반적인 계측기 사양 범위를 초과하는 것으로 나타났다. 생존율의 경우 매설후 손실된 계측기는 2개로 99.5%의 높은 생존율을 나타났다.

  • PDF

분산전원이 연결된 22.9[kV] 배전계통의 양방향 보호기기 실증시험 연구 (The Study on the Actual Examination of the Bidirectional Protection Device in the 22.9[kV] Distribution Power System Interconnected with the DG)

  • 이흥재;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.102-108
    • /
    • 2011
  • The existing power flow has a single direction to the line end but the bidirectional power flow will possibly occur depending on the output capacity in the 22.9[kV] distribution power system connected with the dispersed generation(DG). So these characteristics would influence the power system management. The DG have many advantages such as assistance source, Load share etc. So the utility must apply the bidirectional protection system so as to maximize an advantage of DG. This paper describes the field test case of bidirectional protective device in order to investigate the device performance when applied to bidirectional power system. We have tested in the power system test site of KEPCO and these tests provide the basis for performance verification test of bidirectional protective device in the power system.

IEC 61850기반 IED GOOSE 통신시험 (the GOOSE Communication Test of IEC 61850 based IED)

  • 이남호;이민수;장병태;한정열;송인준;안용호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.263-266
    • /
    • 2009
  • IEC 61850 based substation automation system is operating with Generic Object Oriented Substation Event message when an IED need to send an important signal to other IEDs or receive the signals from another IED such as trip and interlock. So interoperability of substation automation system may be assured throughout the verification of IED GOOSE. This paper shows a testing contents for GOOSE subscription and publish of IEC 61850 based IED and describes how to analysis the result of GOOSE testing. Now domestic IED completed by GOOSE test of this study are working in KEPCO test field.

  • PDF