• 제목/요약/키워드: Field installation test

검색결과 276건 처리시간 0.025초

현장실험에 의한 강성 지오그리드의 내시공성 평가 (Installation Damage Assessment of Rigid Geogrid by Field Tests)

  • 조삼덕;오세용;이광우
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.978-985
    • /
    • 2004
  • Geogrid may be damaged during its installation in the filed. The installation damage mainly depends on two factors, which are materials used and construction activities. Materials relate to geogrid and soils, and construction activities are mainly related to installation of geogrid and compaction of soils. This paper describes the results of a series of field tests, which were conducted to assess the installation damage of the various geogrids according to different fill materials. After field installation damage tests, the change in tensile strength of geogrids was determined from wide width tensile tests using both damaged and undamaged specimens.

  • PDF

현장스미어존 시험에 의한 지반교란특성 분석 (Analysis of Ground Disturbance Characteristics by Field Smear Zones Test)

  • 진규남;이재식;박영목;정하익;진현식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.583-590
    • /
    • 2000
  • The installation of vertical drains by using a mandrel causes significant disturbance of the subsoil. Thus a smear zone may be developed with reduced permeability and increased compressibility. In this paper the extent of smear zone developing ground disturbance with the installation of mandrels are analysed by field smear zone test. The extent and the consolidation characteristics of smear zones around the mandrels is compared with the shape, the size of mandrel and penetration speed and is evaluated from the field smear test results. (circular, sqare, rectangle and oval type)

  • PDF

지오그리드의 시공중 손상 평가를 위한 실험적 연구 (Experimental Study for Installation Damage Assessment of Geogrid)

  • 조삼덕;이광우;오세용
    • 한국환경복원기술학회지
    • /
    • 제8권1호
    • /
    • pp.27-36
    • /
    • 2005
  • Geosynthetic reinforcements may be damaged during its installation in the filed. The installation damage mainly depends on two factors such as materials used and construction activities. This paper describes the results of a series of field tests, which are conducted to assess the installation damage of geogrid according to different maximum grain sizes of fills (40, 60, and 80 mm). These tests are done in three sites for twelve different kinds of geogrids. After field tests, the changes in tensile strength of the geogrids is determined from wide width tensile tests using both damaged and undamaged specimens. In the results of tests, tensile strength of the relatively flexible geogrids after field installation tests was decreased about from 20% to 40% according to the increment of the maximum grain size. On the other hand, for the relatively stiff geogrids, the loss of the tensile strength after site installation was examined below 5.2% independent of the maximum grain size of the soils. The results of this study show that the installation damage significantly depends on the stiffness of geogrid and is more obvious to a flexible geogrid and a fill material having higher maximum grain size.

현장CPT시험에 의한 스미어존의 범위 산정 (Determination of Smear Zone by Field CPT Test)

  • 진규남;김경호;정길수;정하익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 가을 학술발표회 논문집
    • /
    • pp.81-86
    • /
    • 1999
  • The installation of vertical drains by means of a mandrel causes significant remolding of the subsoil, especially in the immediate vicinity of the mandrel. Thus, a zone of smear will be developed with reduced permeability and increased compressibility. This paper is mainly concerned with a field study to investigate the effect of smear due to vertical drain installation. In the present study, a field smear test was conducted to assess the extent of the smear zone around the vertical drain. The extent of the smear zone around a vertical drain was evaluated from the CPT results. CPT test was carried out to some distance around the mandrel installation. The test results revealed that a smear zone was estimated to be 3.6~5.3 times of the mandrel diameter.

  • PDF

초고압 XLPE 전력케이블에 대한 설치후 교류내전압시험 현장적용 (Field Application of AC High Voltage Test after Installation for EHV XLPE Power Cables)

  • 김영;권병일;성정규;한창석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1768-1770
    • /
    • 2001
  • EHV power cables can take any damage during shipping, transportation, handling, storage and installation. As the damage influences a reliability of the power cable system in the short and long periods, field tests have been required, for installers, to confirm the reliability of an installed system and, for utilities, to make sure the compatibility of an installed system. Of field tests, a HV withstand test for the cable insulation has been performed to check the soundness of the insulation. For EHV XLPE power cables, the test has been done by applying a specified d.c voltage till lately. But as some problems with the d.c test is emphasized and the equipment for the a.c test is improved, the a.c test is considered positively as an after-installation test. This paper describes the recent trends of the a and its recent application in the field.

  • PDF

154[kV] 저소음 변압기의 현장적용 (The Field Applica1ion of The 154[kV] low Noise Transformers)

  • 권동진;구교선;우정욱
    • 조명전기설비학회논문지
    • /
    • 제23권8호
    • /
    • pp.124-129
    • /
    • 2009
  • 최근 생활수준의 향상과 세계적인 녹색성장 정책으로 환경에 대한 관심이 고조되어, 전력분야에서도 환경친화적인 설비가 요구되어 지고 있다. 이에 따라 전력용 변압기도 소음저감에 대한 연구가 진행되어, 최근 55[dBA]급 154[kV] 저소음 변압기가 개발되었다. 저소음 변압기는 소음레벨은 저감되었지만, 중량 및 부피의 증가, 고무댐퍼의 적용 등이 변화가 있다. 이로 인하여 현장적용시 시험, 수송, 설치 및 운용 등에 대한 면밀한 검토가 필요한 실정이다. 따라서 본 논문에서는 효과적인 현장적용을 위해 소음레벨 기준치, 수송중량, 설치공간, 장기운용에 대한 사항을 검토하였다.

PQM 및 PQMS 성능검증을 위한 실증시험 (The field-test of Power Quality Meter and Power Management System in order to verify the performance)

  • 최선규;송일근;권태호;한재욱
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.235-239
    • /
    • 2005
  • This paper gives a field-test method and result of PQM(Power Quality Meter) and PQMS(Power Quality Management System). The field-test was carried out as our own method. So, the test method has several kinds of improvement in this paper because it is first time to try the field-test of the equipment. However, we expect that the test result of PQM & PQMS has been used as a reference data which makes a scheme of evaluating performance of the equipment that has been used or is developed.

  • PDF

입도에 따른 지오그리드의 시공손상계수 산정 (Evaluation of Installation Damage Factor for Geogrid with Particle Size)

  • 임성윤;송창섭
    • 한국농공학회논문집
    • /
    • 제52권3호
    • /
    • pp.113-120
    • /
    • 2010
  • Reduction factor for installation damage required to calculate design strength of geogrid used in MSEW(mechanically stabilized earth wall) design is usually obtained in the field test simulating real construction condition. However, damages occurred in geogrid during backfill work are influenced by many factors such as polymer types, unit weight per area, backfill construction method and gradation of backfill material and field test considering these factors demand lots of time and costs. In this study, factors affecting installation damage are analyzed and empirical method to evaluate reduction factor for installation damage using maximum particle size in backfill material is suggested.

복합가속열화시험에 의한 폴리머 피뢰기의 경년특성 (Aging Characteristics of Polymer Lighting Arrester by Multi-Stress Accelerated Aging Test)

  • 송현석;이재봉;장상옥;한용희;오재형
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.86-89
    • /
    • 2004
  • Recently polymer arresters are being used widely but we don't have appropriate long term characteristics test methods. Therefore we need to develop special test facility to evaluate long term reliability of polymer arresters. It's polymeric housing can be degraded by environmental stress and the interface between housing and inner module can be affected by moisture absorption. This moisture absorption can cause leakage current and tracking in the interface. We developed multi stress accelerated ageing test facility to simulate field conditions including UV, temperature, humidity, voltage, salt fog and rain. In addition, we carried out field exposure test at the outdoor test yard and characteristics analysis of field operated specimens to evaluate accelerating factor of this accelerated aging test.

  • PDF

다양한 현장내시공성시험에 근거한 토목섬유 보강재의 시공성 감소계수 평가 (Installation Damage Reduction Factor for Geosynthetics Reinforcements Based on Various Full-Scale Field Installation Tests)

  • 조삼덕;이광우
    • 한국지반신소재학회논문집
    • /
    • 제17권4호
    • /
    • pp.225-238
    • /
    • 2018
  • 본 연구에서는 토목섬유 보강재의 시공중 손상 정도를 규명하기 위하여 국내에서 많이 사용되고 있는 주요 토목섬유 보강재 제품(7개 사의 15 종류)을 대상으로 다양한 입도의 성토재료를 적용한 현장내시공성시험을 수행하였다. 현장내시공성시험은 FHWA(2009) 지침을 참조하여 수행하였으며, 다짐시공 후 추출된 토목섬유 보강재 시료에서 인장강도 시편(크기 $0.2m{\times}1.4m$)을 최대 20개 이상 균등하게 샘플링하여 인장강도시험을 수행함으로써 시공에 따른 인장강도 감소 정도를 분석하였다. 분석 결과, 성토재료의 다짐시공으로 인한 토목섬유 보강재의 인장강도 감소 정도는 토목섬유 보강재의 종류와 성토재료의 최대입경에 크게 영향을 받으며, 비교적 강성이 작은 PET 결합형 지오그리드(PVC 코팅)의 인장강도 감소율이 가장 크게 나타났고, 전반적으로 성토재료의 최대입경이 클수록 인장강도 감소율은 더욱 크게 나타남을 알 수 있었다. 또한, 이 시험결과와 함께 기 수행된 현장내시공성시험 결과들을 분석하여 토목섬유 보강재의 시공성 감소계수를 보다 합리적으로 평가할 수 있는 방안을 제시하였다.