• Title/Summary/Keyword: Field inspection test

Search Result 285, Processing Time 0.028 seconds

Development of Expert System for Maintenance of Tunnel(I) (터널의 유지관리를 위한 전문가시스템 개발(I) : 시스템 구축 및 적용성 검토)

  • Kim, Do-Houn;Huh, Taik-Nyung;Kim, Moon-Kyum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.2
    • /
    • pp.175-184
    • /
    • 2000
  • The maintenance of tunnels is often neglected since tunnels has tendency to become stable with time. The determination of safety of tunnels is a complicated problem. So the role of experienced engineer in the maintenance is very important and development of an expert system which can perform as these engineers has been needed. In this study, an expert system which can determine the safety of tunnels is developed. The developed knowledge base contains the maintenance procedure which is used in KlSTEC(Korea Infrastructure Safety & Technology Corporation). Field test, laboratory test and nondestructive test methods are considered in this knowledge base. Criteria for each item and integrated diagnosis criteria are implemented in the expert system based on literatures and reports. The expert system includes basic inspection. detail inspection and precision inspection. For precision inspection. it has the capacity to exchange the result from numerical analysis by a commercial program FLAC. To verify the expert system. the proposed procedure was compared with an existing tunnel diagnosis report.

  • PDF

The Inspection system development & Field experiments on performance evaluation for O & M RBF (기술사마당_기술자료 - 하상여과공법의 유지관리를 위한 조사장치 개발 및 현장 성능평가)

  • Oh, Ki-Sik;Cho, Tae-Ho
    • Journal of the Korean Professional Engineers Association
    • /
    • v.43 no.2
    • /
    • pp.53-59
    • /
    • 2010
  • This research is about the inspection system which is for maintenance of laterals of local RBF(River bed Filtration). Inspection system is designed for local use in order to endure water resistance up to 50m and it also can examine the internal condition and colgging of laterals by moving inside of the laterals about 100m back and forward. We will conduct performance test of inspection system at the lacal RBF site and present its result.

  • PDF

Development of Portable Multi-function Sensor (Mini CPT Cone + VWC Sensor) to Improve the Efficiency of Slope Inspection (비탈면 점검 효율화를 위한 휴대형 복합센서 개발)

  • Kim, Jong-Woo;Jho, Youn-Beom
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.1
    • /
    • pp.49-57
    • /
    • 2022
  • In order to efficiently analysis the stability of a slope, measuring the shear strength of soil is needed. The Standard Penetration Test (SPT) is not appropriate for a slope inspection due to cost and weights. One of the ways to effectively measure the N-value is the Dynamic Cone Penetration Test (DCPT). This study was performed to develop a minimized multi-function sensors that can easily estimate CPT values and Volumetric Water Content. N value with multi-fuction sensor DCPT showed -2.5 ~ +3.9% error compared with the SPT N value (reference value) in the field tests. Also, the developed multi-fuction sensor system was tested the correlation between the CPT test and the portable tester with indoor test. The test result showed 0.85 R2 value in soil, 0.83 in weathered soil, and 0.98 in mixed soil. As a result of the field test, the multi-function sensor shows the excellent field applicability of the proposed sensor system. After further research, it is expected that the portable multi-function sensor will be useful for general slope inspection.

A Study on the Problem and Improvement of the Fire Detector Test in the Field (화재감지기 현장점검의 문제점 및 개선방안에 관한 연구)

  • Ok, Kyung-Jea;Cha, Ha-Na;Kim, Shi-Kuk;Lee, Chun-Ha
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.180-184
    • /
    • 2008
  • Fire prevention strategies should be aimed at the prevention of structured fire since average annual rates of structured fire have been increased due to economic growth resulted in increasing high rise buildings and multipurpose occupancies over the past ten years. Hence, this study mainly focused on the improve method and problems in the field test of fire detector in compliances with experimental consideration. And it leads us to the flowing conclusions : Firstly, it is necessary to formulate a safety standards on field test. Nowadays, the test enforced in many ways without formulated standard. Therefore it is necessary to be complete the arrangements standardized and how to do the test with formulated safety standards. Second, it is necessary to establish the regal guidance with regard to inspection equipment, ie density, component and temperature of test equipment should be considered. Also the equipment is need to be standardized and improved. Third, fire inspector's competency in their practice should be enhanced. The problems arising from the lack of knowledge and competence regarding inspection could be settled by providing professional education to ensure proficiency in their practice. Specialized training, as has been noted, should be offered in accordance with occupancy type, scale and fire protection system in the fire facilities.

  • PDF

Field Feasibility Study of an Eddy Current Testing System for Steam Generator Tubes of Nuclear Power Plant (원전 증기발생기 와전류검사 시스템 현장적용 연구)

  • Moon, Gyoon-Young;Lee, Tae-Hun;Kim, In-Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2015
  • Steam generator is one of the most important component of nuclear power plant, and it's integrity and reliability are to be assured to high level by pre-service inspection and in-service inspection. To improve the reliability of steam generator heat exchanger tubes and to secure the management of nuclear power plant safely, KHNP CRI recently has developed eddy current testing system for steam generator. KHNP CRI have performed a series of experimental verification and field application to confirm the performance of the developed ECT system in accordance with ASME Code requirements. The ECT system consists of a remote data acquisition unit, an ECT signal acquisition and analysis software, a water chamber robot controller and a probe push-puller. In this paper, we will details of the developed ECT system and the software and their experimental performance. And also we will report the field applying performance and the issues for further steps.

Development of Integrity Assessment Model for Reinforced Concrete Highway Bridges Using Fuzzy Concept (Fuzzy 개념을 이용한 RC도로교의 건전성평가 모델 개발)

  • Na, Ki-Hyun;Park, Ju-Won;Lee, Cheung-Bin;Jung, Chul-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.2
    • /
    • pp.151-161
    • /
    • 1998
  • In this study, an attempt is made to apply the concept of fuzzy-bayesian theory to the integrity assessment of RC highway bridge, and uncertainty states are represented in terms of fuzzy sets which define several linguistic variables such as "very good", "good", "average", "poor", "very poor", etc. Especially, the concept of fuzzy conditional probability aids to derive a new reliability analysis which includes the subjective assessment of engineers without introducing any additional correction factors. The fuzzy concept are also used as reliability indexes for the condition assessment based on the proposed models, the proposed fuzzy theory-based approach with the results of visual inspection and extensive field load tests are applied to the integrity assessment of a new RC highway bridge, namely, Jichok bridge.

  • PDF

Circuit card inspection method through digital circuit design based AITS

  • Han, Ji-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.8
    • /
    • pp.1-7
    • /
    • 2018
  • Previous test equipment was bulky, took a long time to check, and was somewhat less economical. Since most of the checks were about analog signals, we preferred to check them using reference equipments. In this paper, a digital circuit design based on AITS is used to implement signals that can not utilize commercial measurement resources, and also designed and manufactured equipment that can inspect SRU. These test equipments were tested and evaluated by development, operation, and field evaluation, and they were installed to the Korean Field Force. This contributed to the improvement of operability by shortening the inspection time from 83.2 minutes to 7.8 minutes on average In addition, it did not utilize the reference equipment, so it could play a big role in lowering the mass production cost.

A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas (질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구)

  • Lim, Woo-Sub;Jung, Jong-Jin;Nam, Dong-gun;SaKong, Seong-Ho;Kim, Jong-Won;Choi, Kenu-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.