• Title/Summary/Keyword: Field electron microscope

Search Result 556, Processing Time 0.028 seconds

Effects of Selective Growth on Electron-emission Properties of Conical-type Carbon Nanotube Field-emitters (원추형 기판 위에 탄소 나노튜브의 선택적 성장이 전계방출 특성에 미치는 영향)

  • Kim, Bu-Jong;Noh, Young-Rok;Park, Jin-Seok
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.61-65
    • /
    • 2012
  • In this study, for use of carbon nanotubes (CNTs) as a cold cathode of x-ray tubes, we examine the effects of selective growth of CNTs on their field emission properties and long-term stability. The selective growth of CNTs was performed by selectively etching the catalyst layer which was used for CNTs' nucleation. CNTs were grown on conical-type tungsten substrates using an inductively-coupled plasma chemical vapor deposition system. For all the grown CNTs, their morphologies and microstructures were analyzed by field-emission scanning electron microscope and Raman spectroscopy. The electron-emission properties of CNTs and the long-term stability of emission currents were measured and characterized according to the CNTs' growth position on the substrate.

The Effects of Dielectric Coatings on Electron Emission from Tungsten

  • Al-Qudah, Ala'a M.;Alnawasreh, Shady S.;Madanat, Mazen A.;Trzaska, Oliwia;Matykiewicz, Danuta;Alrawshdeh, Saad S.;Hagmann, Mark J.;Mousa, Marwan S.
    • Applied Microscopy
    • /
    • v.47 no.1
    • /
    • pp.36-42
    • /
    • 2017
  • Field electron emission measurements were performed on dielectric-coated tungsten emitters, with apex radii in the nanometer and micrometer range, which were prepared by electrochemical etching in NaOH solution. Measurements were performed in a field electron microscopy (FEM) with a base pressure <$10^{-6}$ Pascal ($10^{-8}$ mbar). Four different types of dielectric were used, namely: (1) Clark Electromedical Instruments epoxylite resin, (2) Epidian 6 produced by Ciech Sarzyna S. A., (3) a Radionox solution of colloidal graphite; and (4) Molyslip 2001 E compound ($MoS_2$ and MoS). Current-voltage measurements and FEM images were used to investigate the characteristics of these composite emitters, and to assess how the different types of dielectric coating affect the suitability of the composite emitter as a potential electron source.

A Study on Unit Cell Design for the Performance Enhancement in PEMFC System (PEMFC 시스템의 성능향상을 위한 단위전지 설계에 관한 연구)

  • Kim Hong-Gun;Kim Yoo-Shin;Yang Sung-Mo;Nah Seok-Chan
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.104-109
    • /
    • 2005
  • The catalyst layer design is one of the most important factors to enhance the performance of PEMFC(Proton Exchange Membrane Fuel Cell) system. The hydrophobic and ion conductive type is studied for the MEA(Membrane Electrolyte Assembly). It is found that those have some limitations for performance enhancement when they are used separately. Thus, the dual catalyst type, a mixed model, is developed for the better MEA performance. In the meantime, the design of flow field plate is subsequently carried out in order to give more enhanced output during its operation. The conductivity of flow field plate showed better performance in the case of manufactured by the more compressed process(20MPa) than by the less compressed process(10MPa). The micro-structure of the flow field plate is examined in details using SEM(Scanning Electron Microscope) to analyse the effects on the different compression processes.

Fabrication and Evaluation of electron beam tip for field emission (전계방출 방식의 전자빔 팁의 제작 및 평가)

  • Kim, Chung-Soo;Kim, Dong-Hwan;Park, Man-Jin;Jang, Dong-Young;Ahn, Sung-Hoon;Han, Dong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1277-1281
    • /
    • 2007
  • A Nano-tip as a cold field emitter for inducing a field emission current has manufactured in many ways. In the paper, the electrochemical etching method is used. Thus, in order to optimize the final shape as the field emitter, the reliable fabrication system for electrochemical etching was constructed. In addition, the effective parameters such as applied voltage, submerged length, meniscus height, electrolyte concentration and environmental condition(vibration, humidity, cut-off time) have investigated in detail. By controlling the parameters, reliable tungsten tip for field emitter was fabricated. And the fabricated tungsten tip was evaluated optically. Finally, the very sharp apex of the tungsten tip was observed with scanning electron microscope.

  • PDF

Property of Nickel Silicides on ICP-CVD Amorphous Silicon with Silicidation Temperature (ICP-CVD 비정질 실리콘에 형성된 처리온도에 따른 저온 니켈실리사이드의 물성 변화)

  • Kim, Jong-Ryul;Choi, Young-Youn;Park, Jong-Sung;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.303-310
    • /
    • 2008
  • We fabricated hydrogenated amorphous silicon(a-Si:H) 140 nm thick film on a $180\;nm-SiO_2/Si$ substrate with an inductively-coupled plasma chemical vapor deposition(ICP-CVD) equipment at $250^{\circ}C$. Moreover, 30 nm-Ni film was deposited with a thermal-evaporator sequently. Then the film stack was annealed to induce silicides by a rapid thermal annealer(RTA) at $200{\sim}500^{\circ}C$ in every $50^{\circ}C$ for 30 minuets. We employed a four-point tester, high resolution X-ray diffraction(HRXRD), field emission scanning electron microscope(FE-SEM), transmission electron microscope(TEM), and scanning probe microscope(SPM) in order to examine the sheet resistance, phase transformation, in-plane microstructure, cross-sectional microstructure evolution, and surface roughness, respectively. We confirmed that nano-thick high resistive $Ni_3Si$, mid-resistive $Ni_2Si$, and low resistive NiSi phases were stable at the temperature of <300, $350{\sim}450^{\circ}C$, and >$450^{\circ}C$, respectively. Through SPM analysis, we confirmed the surface roughness of nickel silicide was below 12 nm, which implied that it was superior over employing the glass and polymer substrates.

Study of Phase Transition of Copper(II)-phthalocyanine using a Near Field Scanning Microwave Microscope (근접장 마이크로파 현미경을 이용한 Copper(II)-phthalocyanine의 Phase Transition 연구)

  • Park, Mie-Hwa;Yoo, Hyun-Jun;Yun, Soon-Il;Lim, Eun-Ju;Lee, Kie-Jin;Cha, Deok-Joon;Lee, Young-San
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.6
    • /
    • pp.641-646
    • /
    • 2004
  • We report the changes of the microwave reflection coefficients S$_{11}$ of copper(II)-phthalocyanine (CuPc) thin films by using a near-field microwave microscope(NSMM) in order to understand the phase transition of CuPc. For a NSMM system, a high-quality microstrip resonator coupled with a dielectric resonator was used. CuPc thin films were prepared on the pre-heated glass substrates using a thermal evaporation method. The reflection coefficients S$_{11}$ of CuPc thin films were changed by the dependence on the substrate pre-heating temperatures. By comparing reflection coefficient S$_{11}$ and crystal structures, we found the phase transition of CuPc thin films from $\alpha$-phase to $\beta$-phase at the substrate heating temperature 200 $^{\circ}C$./TEX>.

Review on asbestos analysis (석면 분석방법에 대한 고찰)

  • Ham, Seung hon;Hwang, Sung Ho;Yoon, Chungsik;Park, Donguk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.3
    • /
    • pp.213-232
    • /
    • 2009
  • This document was prepared to review and summarize the analytical methods for airborne and bulk asbestos. Basic principles, shortcomings and advantages for asbestos analytical instruments using phase contrast microscopy(PCM), polarized light microscopy(PLM), X-ray diffractometer (XRD), transmission electron microscopy(TEM), scanning electron microscopy(SEM) were reviewed. Both PCM and PLM are principal instrument for airborne and bulk asbestos analysis, respectively. If needed, analytical electron microscopy is employed to confirm asbestos identification. PCM is used originally for workplace airborne asbestos fiber and its application has been expanded to measure airborne fiber. Shortcoming of PCM is that it cannot differentiate true asbestos from non asbestos fiber form and its low resolution limit ($0.2{\sim}0.25{\mu}m$). The measurement of airborne asbestos fiber can be performed by EPA's Asbestos Hazard Emergency Response Act (AHERA) method, World Health Organization (WHO) method, International Standard Organization (ISO) 10312 method, Japan's Environmental Asbestos Monitoring method, and Standard method of Indoor Air Quality of Korea. The measurement of airborne asbestos fiber in workplace can be performed by National Institute for Occupational Safety and Health (NIOSH) 7400 method, NIOSH 7402 method, Occupational Safety and Health Administration (OSHA) ID-160 method, UK's Health and Safety Executive(HSE) Methods for the determination of hazardous substances (MDHS) 39/4 method and Korea Occupational Safety and Health Agency (KOSHA) CODE-A-1-2004 method of Korea. To analyze the bulk asbestos, stereo microscope (SM) and PLM is required by EPA -600/R-93/116 method. Most bulk asbestos can be identified by SM and PLM but one limitation of PLM is that it can not see very thin fiber (i.e., < $0.25{\mu}m$). Bulk asbestos analytical methods, including EPA-600/M4-82-020, EPA-600/R-93/116, OSHA ID-191, Laboratory approval program of New York were reviewed. Also, analytical methods for asbestos in soil, dust, water were briefly discussed. Analytical electron microscope, a transmission electron microscope equipped with selected area electron diffraction (SAED) and energy dispersive X-ray analyser(EDXA), has been known to be better to identify asbestiform than scanning electron microscope(SEM). Though there is no standard SEM procedures, SEM is known to be more suitable to analyze long, thin fiber and more cost-effective. Field emission scanning electron microscope (FE-SEM) imaging protocol was developed to identify asbestos fiber. Although many asbestos analytical methods are available, there is no method that can be applied to all type of samples. In order to detect asbestos with confidence, all advantages and disadvantages of each instrument and method for given sample should be considered.

Morphological and Molecular Characterization of Toxocara apodemi (Nematoda: Ascarididae) from Striped Field Mice, Apodemus agrarius, in Korea

  • Kim, Hyeon Cheol;Hong, Eui Ju;Ryu, Si Yun;Park, Jinho;Cho, Jeong Gon;Yu, Do Hyeon;Chae, Joon Seok;Choi, Kyoung Seong;Park, Bae Keun
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.4
    • /
    • pp.403-411
    • /
    • 2020
  • Adult ascarid worms from the field mice, Apodemus agrarius, were observed with a light and scanning electron microscope, and molecularly analized with 18S rRNA gene. In the scanning electron microscope, 3 prominent labia were present in the anterior end of male and female worms, but the interlabia and gubernaculum were absent. Scanning electron micrographs showed cervical alae as vestigial organs that looked like a slightly uplifted superficial sewing stitch. Total 6 pairs of post-cloacal papillae were observed on the tail of the male worms. The tail of female worms was blunt and conical shape with a spine-like structure, mucron. The eggs were sub-globular, coated with the albuminous layer and 73 by 82 ㎛ in average size. The superficial pits of T. apodemi egg (mean 8.6×6.7 ㎛) are obviously bigger than those of Toxocara spp. The partial sequence of 18S rRNA showed the sequence homology of Toxocara canis (99.6%), Toxocara cati (99.4%), Toxascaris leonina (99.4%), and Toxocara vitulorum (99.2%). Conclusively, it was confirmed that ascarid nematodes, Toxocara apodemi, recovered from striped field mice in Korea are taxonomically conspecific relationship with genus Toxocara and genetic divergence from other Toxocara species.

Enlargement of Field-of-View (FOV) of the CCD Camera by the Current Adjustment of the Projection Lens System in the KBSI-HVEM (KBSI-HVEM 투사렌즈 전류제어에 의한 CCD Camera의 Field of View(FOV) 확장)

  • Kim, Young-Min;Shim, Hyo-Sik;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.35 no.4
    • /
    • pp.98-104
    • /
    • 2005
  • A FOV (field-of-view) of the HV-MSC (high voltage multi-scan CCD, $1024{\times}1024$ pixels) camera mounted in the post-column HV-GIF (high voltage gatan image filter) has been drastically enlarged by the projection lens current adjustment. An imaging area of the HV-MSC camera obtained at the lowest magnification (2,000x) is $112{\mu}m^2$ which corresponds to the recording area of the film at the magnification of 8,800x, while the achievable recording area is only $0.43{\mu}m^2$ at the same magnification without this technique. Ignoring the image distortion of less than 5%, we have designed an on-site reference graph to estimate projection lens currents for microscope magnifications above 8,800x, where the recording area on the HVMSC is same as that on the film.

FIT OF FIXTURE/ABUTMENT/SCREW INTERFACES OF INTERNAL CONNECTION IMPLANT SYSTEM

  • Kim, Jin-Sup;Kim, Hee-Jung;Chung, Chae-Heon;Baek, Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.338-351
    • /
    • 2005
  • Statement of problem. Accurate fit between the implant components is important because the misfit of the implant components results in frequent screw loosening, irreversible screw fracture, plaque accumulation, poor soft tissue reaction, and destruction of osseointegration. Purpose. This study is to evaluate the machining accuracy and consistency of the implant fixture/ abutment/screw interfaces of the internal connection system by using a Stereoscopic Zoom microscope and FE-SEM(field emission scanning electron microscope) Materials and methods. The implant systems selected in this study were internal connection type implants from AVANA(Osstem^{\circledR}), Bioplant(Cowell-Medi^{\circledR}), Dio(DIO^{\circledR}), Neoplant(Neobiotech 􀋓), Implantium(Dentium􀋓)systems. Each group was acquired 2 fixtures at random. Two piece type abutment and one piece type abutment for use with each implant system were acquired. Screw were respectively used to hold a two piece type abutment to a implant fixture. The implant fixtures were perpendiculary mounted in acrylic resin block. Each two piece abutment was secured to the implant fixture by screw and one piece abutment also secured to the implant fixture. Abutment/fixture assembly were mounted in liquid unsaturated polyester. All samples were cross-sectioned with grinder-polisher unit. Finally all specimens were analysed the fit between implant fixture/abutment/screw interfaces Results and conclusions. 1. Implant fixture/abutment/screw connection interfaces of internal connection systems made in Korea were in good condition. 2. The results of the above study showed that materials and mechanical properties and quality of milling differed depending on their manufacturing companies.