• Title/Summary/Keyword: Field Reduction Factor

Search Result 229, Processing Time 0.029 seconds

Determination of Model Parameters of Surface Cover Materials in Evaluation of Sediment Reduction and Its Effects at Watershed Scale using SWAT (토양유실 저감을 위한 지표피복 저감효과 변수 결정 및 SWAT 모형 유역단위 효과 분석)

  • Kum, Donghyuk;Jang, Chun Hwa;Shin, Min Hwan;Choi, Joong-Dae;Kim, Bomchul;Jeong, Gyo-Cheol;Won, Chul Hee;Lim, Kyoung Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.923-932
    • /
    • 2012
  • The purpose of this study was to determine parameters of surface cover materials and evaluation the effects on runoff and sediment reductions with rice straw mat with PAM at watershed scale using the SWAT model. In this study, 1) regression equation of CN for rice straw mat + PAM using SCS curve number method was developed, 2) the USLE P factor, being able to reflect simulation of rice straw mat + PAM in the agricultural field, was estimated for various slope scenarios with VFSMOD-w. Then regression equation for CN and USLE P factor were used as input data in the SWAT model. Assuming rice straw mat + PAM is applied to radish and potato fields, occupying 24% of agricultural fields at the study watershed. Result of direct runoff without rice straw mat + PAM was $65,964,368\;m^3,$ with rice straw mat + PAM, direct runoff was $65,637,336\;m^3$, $327,031.8\;m^3$ reductions compared without it. Also, result of sediment without rice straw mat + PAM was 163,531 ton, with rice straw mat + PAM, sediment was 84,779 ton, 78,752 ton reduction compared without it. This analysis showed that about 48% sediment reductions would be expected with rice straw mat + PAM. As shown in this study, rice straw mat + PAM would be used as an efficient site-specific BMPs to reduce runoff and sediment discharge from field.

Extremely Low Frequency Magnetic Field is an Environmental Stress Factor by Exerting Oxidative Stress

  • Park, Yong-Jin;Park, Won-Joo;Yim, Sung-Hyuk;Yang, Seong-Jun;Sun, Yuan Lu;Jeong, Ji-Hoon;Park, Eon-Sub
    • Biomolecules & Therapeutics
    • /
    • v.15 no.1
    • /
    • pp.58-64
    • /
    • 2007
  • The previous study reported the biological effect of magnetic field exerted by acting on endocrine and anti-oxidant system. The present study aims to study whether ELF-MF (extremely low frequency magnetic field) affects the physiological endocrine systems such as thyroid and whether ELF-MF affects the defense system against oxidative stress when it alters the function of thyroid. Finally, we correlate the effects of MF on oxidative stress, and adrenal and thyroid with an environmental stress factor. We exposed sham or MF to rats for 5 or 25 days. After the exposure, we determined pain sensitivity, level of TSH, $T_3$ and free $T_4$ in plasma. We also assayed in whole brain, lipid peroxidation, the activity of enzymatic anti-oxidant defense including superoxide dismutase(SOD) and glutathione peroxidase (GPx), and non enzymatic defense such as reduced or oxidized glutathione contents. MF induced the hypersensitivity to thermal stimuli with the reduction of latency. $T_3$ and $T_4$ levels were also increased by the exposure of MF. In addition, we observed the rise of MDA level in rat brain by MF although the MF did not change superoxide dismutase and glutathione peroxidase activity. The effect of MF on both reduced and oxidized glutathione results in decrease in reduced or oxidized glutathione in whole brain. In every experiment, there was no significant difference in MF influence between short term (5 days) and long term (25 days) exposure. Taken together, MF exposure affects the thyroid hormonal control in brain. The elevated thyroid hormone acts on brain, leading to hyper-utilization of oxygen. This phenomenon may be correlated with oxidative stress resulting from MF exposure. In conclusion, we suggest that MF exposure may be an environmental stress by exerting oxidative stress.

Effects of GSI and Joint Orientation on the Change of Hydraulic Conductivity (GSI 및 절리의 방향이 수리전도도 변화에 미치는 영향)

  • Yoon, Yong-Kyun
    • Tunnel and Underground Space
    • /
    • v.20 no.3
    • /
    • pp.225-232
    • /
    • 2010
  • In this study, a newly modified 3-dimensional strain-dependent hydraulic conductivity modification relation which incorporates the influences of normal deformation and shear dilation is suggested. Since rock mass is simulated as a orthogonally jointed medium, an anisotropic hydraulic conductivity field can be evaluated using that relation. The empirical relationship on the basis of GSI and disturbance factor has been used to estimate the value of a modulus reduction ratio (ratio of rock mass deformation modulus to rock matrix elastic modulus). Principal hydraulic conductivity directions is not generally coincident with the global coordinate due to the inclining of joint and the influence of joint inclination is evaluated under strain rotation. Result shows that change of hydraulic conductivity does decreases with the increase of GSI and disturbance factor has much effects on the hydraulic conductivity of rock mass getting GSI value above 50. It is found that the inclination of joint impacts on the variation of hydraulic conductivity.

Evaluation of Friction and Hydroplaning Characteristic in Aifield Using Dry Grooving Method (건식그루빙을 사용한 공항 활주로의 마찰 및 수막현상 특성평가)

  • Park, Tae-Soon
    • International Journal of Highway Engineering
    • /
    • v.3 no.3 s.9
    • /
    • pp.111-118
    • /
    • 2001
  • Since the advent of turbojet aircraft with their greater weight and high landing speed breaking performance on runway surface has become un critical. Under certain weather conditions(wet weather, winter) hydroplaning or unacceptable loss of traction can occur, resulting in poor braking performance and possible loss of directional control. To address this concern a number of research project me conducted by NASA, FAA, USAF. The various method which was reported the advantage of the increasing the friction and decreasing the hydroplaning effect. A-2 section of inchon international airport was grooved using drying grooving method. In order to evaluate the effectiveness of the dry grooving method the surface was spray with water and measured the fiction factor and the depth of the water using Mu meter and water depth measuring device. The field test results shooed that the fiction factor nos increased and the depth of the water decreased. The dry grooving method illustrated the reduction of hydroplaning and also, no distress on the runway.

  • PDF

Analyzing the Level and Influence Factors for Work Performance of Field Managers in General Construction Companies (일반건설업체 현장관리자의 직무별 업무수행수준 및 영향요인 분석)

  • Park, Kyoung-Hun;Son, Chang-Baek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.3
    • /
    • pp.115-124
    • /
    • 2010
  • Along with the recent economic downturn, domestic construction companies have also faced with many difficulties and obstacles. To overcome this situations, now they are trying to continuous efforts to improve efficiency and productivity of project performance through many means including the reduction of fixed cost expenditures. Level of work performance of construction field managers is very important factor of productivity improvement for successive performance of construction project. This study attempts to analyse level and influence factors for work performance of field managers in construction companies through analysis of work burden and level of work performance. Also this study attempts to present basic data of the improvement directions for enhancing construction efficiency and productivity in future.

Load Carrying Capacity Evaluation of Single Span Bridge using Impact Factor Response Spectrum (충격계수 응답스펙트럼을 이용한 단경간 교량의 내하력 평가)

  • Lee, Huseok;Roh, Hwasung;Park, Kyung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.730-736
    • /
    • 2016
  • In a previous study, the impact factor response spectrum and corresponding method for evaluating the load carrying capacity of bridges was suggested to improve the existing evaluation method. To verify the applicability of the suggested method, which is based on the frequency of bridges, the dynamic characteristic test for an actual single span simply-supported bridge was conducted. Through a field test under ambient traffic conditions, the dynamic response of the bridge was obtained using wireless accelometers and its fundamental frequency was identified. The peak impact factor was determined from the identified frequency and the impact factor response spectrum. The load carrying performance variation of the bridge was estimated considering the performance reduction factor, which was calculated using the current and previous natural frequency and impact factor. From the result, the load carrying capacity of the bridge was decreased, but the capacity was still enough because its value is greater than the design live load. Through the overall procedures and technical details presented in this paper, the suggested evaluation method can be applied to actual bridges with the acceleration data measured under ambient traffic conditions and the impact factor response spectrum.

Enhancement of Dewaterability of Sewage Sludge by Ultrasonification and Electric Field Treatment (초음파와 전기장 처리에 의한 하수슬러지 탈수성 향상)

  • Mo, Woojong;Han, Jisun;Ahn, Changmin;Yoon, Soonuk;Seok, Heejung;Kim, Changgyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2013
  • The sludge disposal is a major economic factor in the sewage treatment facility operation. Moreover, since the ocean dumping will be prohibited by Korean environmental law from 2013, sludge should be eliminated or sludge volumetric reduction should be performed urgently. In this study, improvement of the sewage sludge dewaterability was investigated by ultrasound and electric field treatment. Sludge was treated by a single or in combination of either the electric field or ultrasound on a pilot pretreatment facility, then it was dewatered by lab-scale filter press. The operating input energy of ultrasound device was varied from 225~1,200 kJ/L and electric field device was varied from 4.5~24 kJ/L. The water contents of dewatered sludge cake treated with ultrasound (1,200 kJ/L) and combination of ultrasound/electric field (1,224 kJ/L) were decreased 10~12% by comparing non-treated sludge. At that time, water contents were 65~66%. The combination treatment of ultrasound/electric field was effective to reduce water content of dewatered sludge cake, however, water content was not changed by a single treatment of electric field because of low energy density.

Prognostic value of pretreatment 18F-FDG PET-CT in radiotherapy for patients with hepatocellular carcinoma

  • Jo, In Young;Son, Seok-Hyun;Kim, Myungsoo;Sung, Soo Yoon;Won, Yong Kyun;Kang, Hye Jin;Lee, So Jung;Chung, Yong-An;Oh, Jin Kyoung;Kay, Chul-Seung
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.179-187
    • /
    • 2015
  • Purpose: The purpose of this study was to investigate the predictable value of pretreatment $^{18}F$-fluorodeoxyglucose positron emission tomography-computed tomography ($^{18}F$-FDG PET-CT) in radiotherapy (RT) for patients with hepatocellular carcinoma (HCC) or portal vein tumor thrombosis (PVTT). Materials and Methods: We conducted a retrospective analysis of 36 stage I-IV HCC patients treated with RT. $^{18}F$-FDG PET-CT was performed before RT. Treatment target was determined HCC or PVTT lesions by treatment aim. They were irradiated at a median prescription dose of 50 Gy. The response was evaluated within 3 months after completion of RT using the Response Evaluation Criteria in Solid Tumors (RECIST). Response rate, overall survival (OS), and the pattern of failure (POF) were analyzed. Results: The response rate was 61.1%. The statistically significant prognostic factor affecting response in RT field was maximal standardized uptake value (maxSUV) only. The high SUV group (maxSUV ${\geq}5.1$) showed the better radiologic response than the low SUV group (maxSUV < 5.1). The median OS were 996.0 days in definitive group and 144.0 days in palliative group. Factors affecting OS were the %reduction of alpha-fetoprotein (AFP) level in the definitive group and Child-Pugh class in the palliative group. To predict the POF, maxSUV based on the cutoff value of 5.1 was the only significant factor in distant metastasis group. Conclusion: The results of this study suggest that the maxSUV of $^{18}F$-FDG PET-CT may be a prognostic factor for treatment outcome and the POF after RT. A %reduction of AFP level and Child-Pugh class could be used to predict OS in HCC.

Development and Application of Automatic Rainfall Field Tracking Methods for Depth-Area-Duration Analysis (DAD 분석을 위한 자동 강우장 탐색기법의 개발 및 적용)

  • Kim, Yeon Su;Song, Mi Yeon;Lee, Gi Ha;Jung, Kwan Sue
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.4
    • /
    • pp.357-370
    • /
    • 2014
  • This study aims to develop a rainfall field tracking method for depth-area-duration (DAD) analysis and assess whether the proposed tracking methods are able to properly estimate the maximum average areal rainfall (MAAR) within the study area during a rainfall period. We proposed three different rainfall field tracking algorithms (Box-tracking, Point-tracking, Advanced point-tracking) and then applied them to the virtual rainfall field with 1hr duration and also compared DAD curves of each method. In addition, we applied the three tracking methods and a traditional GIS-based tool to the typhoon 'Nari' rainfall event of the Yongdam-Dam watershed and then assess applicability of the proposed methods for DAD analysis. The results showed that Box-tracking was much faster than the other two tracking methods in terms of searching for the MAAR but it was impossible to describe rainfall spatial pattern during its tracking processes. On the other hand, both Point-tracking and Advanced point-tracking provided the MAAR by considering the spatial distribution of rainfall fields. In particular, Advanced point-tracking estimated the MAAR more accurately than Point-tracking in the virtual rainfall field, which has two rainfall centers with similar depths. The proposed automatic rainfall field tracking methods can be used as effective tools to analyze DAD relationship and also calculate areal reduction factor.

Technique to Evaluate Safety and Loaded Heavy Equipment Grade in RC Building during Demolition Work (RC건축물 해체공사의 안전성 평가기법 및 탑재장비 등급 제안)

  • Park, Seong-Sik;Lee, Bum-Sik;Kim, Hyo-Jin;Sohn, Chang-Hak
    • Land and Housing Review
    • /
    • v.2 no.2
    • /
    • pp.195-204
    • /
    • 2011
  • During mechanical demolition of RC structures, weights of dismantling equipment and demolition waste of building are applied to unexpected load which did not be considered during the design of structural member. Nevertheless, the loading of dismantling equipment and dismantling process are mainly dependent on field managers' field workers' or experiences without considering safety of structural member by a structural engineer. It is urgently required that reflecting actual circumstance of mechanical demolition, safety evaluation method to evaluate the safety and the guideline for appropriate capacity of structural member to support dismantling equipment weight, be provided. Through site investigation and questionnaire on field workers, this paper proposed demolition waste load, load factor, strength reduction factor, and so on. These are essential to safe evaluation of a building, ready to demolition. Considering actual circumstance of mechanical demolition, safety evaluation method of building and design method of slab and beam was suggested to a dilapidated building. An capability to loading of dismantling equipment was proposed, applied to RC slab and RC beam. Therefore, the suggested safety evaluation method and the guideline for an capability to loading of dismantling equipment weight can reasonably evaluate the capacity of structural member in demolition and use effectively as increasing efficiency and improving safety of demolition through proper management of dismantling equipments.